Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20030D563 + (20:07:29, 20 December 2024)
- ML20030D561 + (20:07:30, 20 December 2024)
- 05000277/LER-1981-037-01, /01T-0:on 810808,HPCI Turbine Exhaust Line Drain Valve A04248 Failed Closed & Redundant Isolation Valve Was Not Closed.Caused by Open Coil on Asco Solenoid Valve. Coil & Solenoid Valve Replaced + (20:07:32, 20 December 2024)
- 05000338/LER-1981-064-03, /03L-0:on 810803,during Monthly Operability Test, Train a Low Head Safety Injection Pump 1-SI-P-1A Failed to Start.Caused by Failure of Associated Circuit Breaker to Close Due to Burned Up Charging Motor.Motor Replaced + (20:07:34, 20 December 2024)
- ML20030D556 + (20:07:36, 20 December 2024)
- 05000277/LER-1981-037, Forwards LER 81-037/01T-0.Detailed Event Analysis Submitted + (20:07:37, 20 December 2024)
- 05000338/LER-1981-064, Forwards LER 81-064/03L-0 + (20:07:40, 20 December 2024)
- ML20030D550 + (20:07:41, 20 December 2024)
- IR 05000483/1981017 + (20:07:43, 20 December 2024)
- ML20030D543 + (20:07:47, 20 December 2024)
- ML20030D540 + (20:07:48, 20 December 2024)
- ML20030D538 + (20:07:50, 20 December 2024)
- ML20030D537 + (20:07:52, 20 December 2024)
- ML20030D535 + (20:07:53, 20 December 2024)
- ML20030D534 + (20:07:57, 20 December 2024)
- 05000311/LER-1981-071, Forwards LER 81-071/03L-0.Detailed Event Analysis Encl + (20:07:59, 20 December 2024)
- ML20030D530 + (20:08:00, 20 December 2024)
- ML20030D529 + (20:08:02, 20 December 2024)
- L-81-366, Final Deficiency Rept Re Mounting of Allen Bradley Control Switches on Control Panels for Safety Injection Control Valves,Initially Reported 810624.Switches Are Spares & Will Be Removed.Deficiency Not Reportable + (20:08:03, 20 December 2024)
- 05000293/LER-1981-042-04, /04T-0:on 810814,received Analysis Rept from Environ Lab Indicating Reportable Concentration of Cs-134 & Cs-137 from 810527 Sample Collection.Possibly Caused by Hot Particle Contained in Controlled Releases + (20:08:05, 20 December 2024)
- ML20030D526 + (20:08:07, 20 December 2024)
- 05000293/LER-1981-042, Forwards LER 81-042/04T-0 + (20:08:08, 20 December 2024)
- ML20030D523 + (20:08:10, 20 December 2024)
- 05000260/LER-1981-042-03, /03L-0:on 810803,suppression Chamber High Level Sensors LS-73-57A & LS-73-57B Operated Time Delay Relay 23AK51 at Correct Setpoint But Parameter Sensor Relay 23AK15 Did Not Operate.Probably Caused by Timing Circuitry Failure + (20:08:11, 20 December 2024)
- ML20030D521 + (20:08:13, 20 December 2024)
- 05000260/LER-1981-042, Forwards LER 81-042/03L-0 + (20:08:15, 20 December 2024)
- ML20030D516 + (20:08:17, 20 December 2024)
- ML20030D515 + (20:08:18, 20 December 2024)
- ML20030D514 + (20:08:19, 20 December 2024)
- AECM-81-289, Interim Deficiency Rept 2 Re Nonconformances in Installation of safety-related Pipe Hangers,Initially Reported on 800319. Rework Completed.Disposition of Inaccessible Hangers Underway.Final Rept by 810930 + (20:08:20, 20 December 2024)
- ML20030D512 + (20:08:22, 20 December 2024)
- ML20030D511 + (20:08:23, 20 December 2024)
- 05000296/LER-1981-038-03, /03L-0:on 810802,reactor Core Isolation Cooling Steam Supply Isolation Valve 3-FCV-71-3 Could Not Be Electrically Operated.Caused by Open Shunt Field.Motor Replaced + (20:08:25, 20 December 2024)
- ML20030D508 + (20:08:26, 20 December 2024)
- ML20030D507 + (20:08:27, 20 December 2024)
- 05000296/LER-1981-038, Forwards LER 81-038/03L-0 + (20:08:29, 20 December 2024)
- ML20030D504 + (20:08:30, 20 December 2024)
- IR 05000413/1981010 + (20:08:35, 20 December 2024)
- ML20030D500 + (20:08:41, 20 December 2024)
- ML20030D497 + (20:08:43, 20 December 2024)
- 05000327/LER-1981-095-03, /03L-0:on 810730,shaft Seal on Emergency Raw Cooling Water Strainer 1B-B Failed.Ercw Headers 1B-B & 1A-A Were cross-tied to Allow Repairs,Leaving Only One Loop Available.Caused by Loose Packing Gland Nuts + (20:08:45, 20 December 2024)
- ML20030D493 + (20:08:48, 20 December 2024)
- IR 05000395/1981016 + (20:08:51, 20 December 2024)
- L-81-367, Interim Deficiency Rept Re Linear Indication in RCS Piping Weld,Initially Reported on 810624.Weld Has Been Repaired. Final Rept Scheduled for 810924 + (20:08:52, 20 December 2024)
- IR 05000298/1981015 + (20:08:54, 20 December 2024)
- 05000327/LER-1981-095, Forwards LER 81-095/03L-0 + (20:08:56, 20 December 2024)
- ML20030D487 + (20:08:58, 20 December 2024)
- IR 05000553/1981005 + (20:09:01, 20 December 2024)
- ML20030D485 + (20:09:03, 20 December 2024)
- ML20030D483 + (20:09:04, 20 December 2024)
- ML20030D481 + (20:09:05, 20 December 2024)