Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20040B851 + (03:15:06, 20 December 2024)
- IR 05000313/1981033 + (03:15:09, 20 December 2024)
- ML20040B849 + (03:15:11, 20 December 2024)
- ML20040B847 + (03:15:12, 20 December 2024)
- IR 05000285/1981031 + (03:15:13, 20 December 2024)
- ML20040B843 + (03:15:15, 20 December 2024)
- ML20040B844 + (03:15:15, 20 December 2024)
- ML20040B842 + (03:15:16, 20 December 2024)
- ML20040B841 + (03:15:17, 20 December 2024)
- ML20040B840 + (03:15:17, 20 December 2024)
- ML20040B838 + (03:15:18, 20 December 2024)
- ML20040B837 + (03:15:19, 20 December 2024)
- ML20040B836 + (03:15:20, 20 December 2024)
- ML20040B835 + (03:15:21, 20 December 2024)
- ML20040B834 + (03:15:22, 20 December 2024)
- ML20040B833 + (03:15:23, 20 December 2024)
- ML20040B832 + (03:15:24, 20 December 2024)
- 05000317/LER-1981-084-03, /03L-0:on 811215,plant Computer Failed Rendering Incore Detector Monitoring Sys Inoperable.Caused by Failure of Typewriter Drive Sys During Entry of Program Instructions.Typewriter Replaced & Necessary Info Reloaded + (03:15:25, 20 December 2024)
- ML20040B827 + (03:15:28, 20 December 2024)
- ML20040B826 + (03:15:29, 20 December 2024)
- ML20040B825 + (03:15:30, 20 December 2024)
- 05000344/LER-1981-031-03, /03L-0:on 811215,containment Recirculation Sump Suction Valve Failed to Reopen During Inservice Testing of Train B ECCS Valves at Full Power.Caused by Failure of Torque Limit Switch Due to Mechanical Shock + (03:15:32, 20 December 2024)
- 05000317/LER-1981-084, Forwards LER 81-084/03L-0 + (03:15:34, 20 December 2024)
- 05000344/LER-1981-031, Forwards LER 81-031/03L-0.Detailed Event Analysis Encl + (03:15:36, 20 December 2024)
- PNO-II-82-007, on 820111,higher than Normal Airborne Radioactivity Level Was Detected by Continuous Air Monitor in Radwaste Bldg Which Serves All Units.Possibly Caused by Water Level in Radwaste Tank Dropping Below Offgas Hose + (03:15:38, 20 December 2024)
- 05000245/LER-1981-038, Forwards LER 81-038/03L-1.Detailed Event Analysis Encl + (03:15:40, 20 December 2024)
- ML20040B816 + (03:15:41, 20 December 2024)
- ML20040B814 + (03:15:43, 20 December 2024)
- ML20040B815 + (03:15:43, 20 December 2024)
- 05000318/LER-1981-057-03, /03L-0:on 811215,excessive Leak Rate Discovered Past Containment Personnel Air Lock Outer Door.Caused by Loose Handwheel Shaft Penetration Seal.Seal Packing Gland Tightened + (03:15:45, 20 December 2024)
- ML20040B811 + (03:15:47, 20 December 2024)
- 05000318/LER-1981-057, Forwards LER 81-057/03L-0 + (03:15:48, 20 December 2024)
- 05000267/LER-1981-074-03, /03L-0:on 811214,cold Reheat Snubber CRS-219 Found Detached from Pipe Mounting,Rendering Snubber Operable.Caused by Failure of Cotter Pin,Allowing Eyebolt to Be Displaced Out of Pipe & Snubber Rod Mounting + (03:15:50, 20 December 2024)
- ML20040B807 + (03:15:51, 20 December 2024)
- ML20040B806 + (03:15:52, 20 December 2024)
- PNO-II-82-006, on 820112,w/turbine Rolling,Turbine Throttle Valves Unexpectedly Opened,Resulting in High Steam Flow Signal Causing Reactor Trip & Automatic Safety Injection. Auxiliary Feed Pump Failed.All Other Safety Sys Functioned + (03:15:57, 20 December 2024)
- 05000324/LER-1981-140-03, /03L-0:on 811218,reactor Coolant I-131 Dose Equivalent Exceeded Tech Spec Limits.Caused by Inadequate Procedures Combined W/Failure to Recognize Trend.Involved Personnel Counseled & Applicable Procedures Reviewed + (03:15:59, 20 December 2024)
- IR 05000445/1981019 + (03:16:01, 20 December 2024)
- 05000267/LER-1981-074, Forwards LER 81-074/03L-0.Detailed Event Analysis Encl + (03:16:03, 20 December 2024)
- ML20040B800 + (03:16:05, 20 December 2024)
- ML20040B799 + (03:16:06, 20 December 2024)
- 05000324/LER-1981-140, Forwards LER 81-140/03L-0 + (03:16:07, 20 December 2024)
- ML20040B795 + (03:16:09, 20 December 2024)
- ML20040B793 + (03:16:10, 20 December 2024)
- ML20040B792 + (03:16:10, 20 December 2024)
- 05000267/LER-1981-075-03, /03L-0:on 811221,two Sample Flow Circuits Found Out of Calibr During Annual Calibr of Primary Coolant Moisture Scram Instrumentation.Caused by Change in Instrument Characteristics.Procedures Being Revised + (03:16:12, 20 December 2024)
- 05000293/LER-1981-058, Submits Followup to 811109 LER 81-058/01T-0.Corrective Actions:Carbon Dioxide Fire Suppression Sys in Cable Spreading Room Will Include Mods or Replacement w/Halon-1301 Sys.Fire Patrols Initiated + (03:16:17, 20 December 2024)
- 05000302/LER-1981-079-03, /03L-0:on 811218,while Increasing Reactor Power, Operator Noted a once-through Steam Generator Operating Level Not Trending Up W/Reactor Power.Caused by Failure of Level Transmitter Amplifier LT-2.Amplifier Replaced + (03:16:19, 20 December 2024)
- 05000302/LER-1981-081-03, /03L-0:on 811222,while Maintaining Steam Header Pressure for Turbine testing,MSV-35 Code Relief Was Continuously Relieving Approx 50 Lb Below Tech Spec Setpoint.Caused by Setpoint Drift.Valve Lift Setpoint Reset + (03:16:21, 20 December 2024)
- ML20040B787 + (03:16:22, 20 December 2024)
- PNO-II-82-009, on 820116,reactor Scrammed Following Turbine Trip.Rcic Manually Operated to Control Water Level.Operator to Manually Initiate Torus Cooling & Found Both RHR Subsystems Inoperable + (03:16:24, 20 December 2024)