- 05000247/LER-1982-035, Forwards LER 82-035/03L-0 + (02:18:52, 17 December 2024)
- 05000254/LER-1982-027, Forwards LER 82-027/03L-0 + (02:18:52, 17 December 2024)
- 05000346/LER-1982-043-03, /03L-0:on 820829,fire Door 428C to Electrical Isolation Room 429A Found Cracked Open.Caused by Component Failure.Latch Mechanism Repaired + (02:18:54, 17 December 2024)
- 2CAN108202, Responds to NRC Transmitting Amend 24 to License NPF-6 Re Seized Reactor Coolant Pump Shaft Event Reanalysis. Event Description & Results of Cycle 2 Seized Rotor Event Encl + (02:18:55, 17 December 2024)
- ML20063P440 + (02:18:55, 17 December 2024)
- 05000346/LER-1982-043, Forwards LER 82-043/03L-0 + (02:18:56, 17 December 2024)
- 05000366/LER-1982-109, Forwards LER 82-109/03L-0 + (02:18:56, 17 December 2024)
- 05000331/LER-1982-058-03, /03L-0:on 820910,river Water Supply Sys Traveling Screen 1F-36B Would Not Run in Auto or Continuous Mode. Caused by Low Discharge Pressure for Screen Wash Pump. Permissive Pressure Switch PS-2903 Recalibr + (02:18:58, 17 December 2024)
- 05000331/LER-1982-058, Forwards LER 82-058/03L-0 + (02:18:59, 17 December 2024)
- ML20063P420 + (02:18:59, 17 December 2024)
- 05000387/LER-1982-019-01, /01T-0:on 820920,during Power Ascension Testing, Turbine Bldg Vent Monitor Sys Became Inoperable.Caused by Failure to Remove Mechanical Vacuum Pump from Svc.Pump Stopped & Steam Jet Air Ejectors Placed in Svc + (02:19:04, 17 December 2024)
- 05000313/LER-1982-026-03, /03L-0:on 820901,installed Hose Reel (HR-49) Found Not Visually Inspected Per Tech Specs.Caused by Lack of Communication,Leading to Omission of HR-49 from Insp procedures.HR-49 Inspected & Procedure Revised + (02:19:06, 17 December 2024)
- ML20063P416 + (02:19:07, 17 December 2024)
- 05000313/LER-1982-026, Forwards LER 82-026/03L-0 + (02:19:08, 17 December 2024)
- ML20063P407 + (02:19:08, 17 December 2024)
- ML20063P406 + (02:19:09, 17 December 2024)
- 05000387/LER-1982-018-03, /03L-0:on 820902,w/mode Switch in Refuel,Three Out of Four Source Range Monitors Were Inoperable.Caused by Inadvertent Stressing of Cables During Undervessel Work. Procedure Revised to Reduce Cable Wear + (02:19:10, 17 December 2024)
- ML20063P401 + (02:19:11, 17 December 2024)
- 05000346/LER-1982-031-03, /03X-2:on 820625 & 0706,fire Barrier Doors 500 & 426 Found Slightly Open.On 820629,fire Barrier & Negative Pressure Door 302 Found Slightly Open.Caused by Closure Mechanism Failure to Seat Doors Tightly Due to Design Error + (02:19:13, 17 December 2024)
- 05000387/LER-1982-018, Forwards LER 82-018/03L-0 + (02:19:14, 17 December 2024)
- ML20063P398 + (02:19:14, 17 December 2024)
- 05000387/LER-1982-020-03, /03L-0:on 820903,after Both RHR Sys Trains Removed from Svc,Pressure & Temp Were Not Recorded.Caused by Operator Misjudgment.Operators Instructed to Log & Follow All Action Statements + (02:19:17, 17 December 2024)
- 05000346/LER-1982-031, Forwards LER 82-031/03X-2 + (02:19:20, 17 December 2024)
- ML20063P390 + (02:19:20, 17 December 2024)
- 05000311/LER-1982-109, Forwards LER 82-109/01T-0.Detailed Event Analysis Encl + (02:19:21, 17 December 2024)
- 05000387/LER-1982-020, Forwards LER 82-020/03L-0 + (02:19:21, 17 December 2024)
- ML20063P380 + (02:19:22, 17 December 2024)
- ML20063P381 + (02:19:22, 17 December 2024)
- ML20063P378 + (02:19:23, 17 December 2024)
- 05000311/LER-1982-105-03, /03L-0:on 820908,svc Water Flow to Containment Fan Coil Unit 22 Found Less than Required by Tech Specs.Caused by Silt Deposited in Cooling Coils Restricting Svc Water Flow.Pressure Control Valve Cycled to Flush Out Silt + (02:19:25, 17 December 2024)
- ML20063P374 + (02:19:26, 17 December 2024)
- ML20063P373 + (02:19:26, 17 December 2024)
- 05000311/LER-1982-105, Forwards LER 82-105/03L-0.Detailed Event Analysis Encl + (02:19:27, 17 December 2024)
- ML20063P372 + (02:19:27, 17 December 2024)
- ML20063P366 + (02:19:28, 17 December 2024)
- ML20063P365 + (02:19:29, 17 December 2024)
- ML20063P362 + (02:19:29, 17 December 2024)
- 05000254/LER-1982-029-01, /01T-0:on 820916,two Small Cracks Found in Heat Affected Zone of Welds 12S-F9 & F10 of Reactor Water Cleanup Sys Piping.Caused by Stress Corrosion.Piping to Be Replaced W/Stainless Steel Pipe & Fittings Prior to Startup + (02:19:31, 17 December 2024)
- ML20063P355 + (02:19:32, 17 December 2024)
- 05000254/LER-1982-029, Forwards LER 82-029/01T-0 + (02:19:33, 17 December 2024)
- ML20063P351 + (02:19:33, 17 December 2024)
- 05000302/LER-1982-045-03, /03L-0:on 820706,emergency Feedwater Ultrasonic Flow Indicator FW-313-FI Discovered Inoperable & Train B Arbitrarily Declared Inoperable.Caused by Failed Power Supply.Power Supply Replaced & Indicator Repaired + (02:19:35, 17 December 2024)
- ML20063P349 + (02:19:36, 17 December 2024)
- ML20063P348 + (02:19:37, 17 December 2024)
- ML20063P345 + (02:19:37, 17 December 2024)
- ML20063P342 + (02:19:38, 17 December 2024)
- ML20063P339 + (02:19:39, 17 December 2024)
- ML20063P338 + (02:19:39, 17 December 2024)
- ML20063P334 + (02:19:40, 17 December 2024)
- ML20063P335 + (02:19:40, 17 December 2024)
- ML20063P333 + (02:19:41, 17 December 2024)
- ML20063P331 + (02:19:42, 17 December 2024)