Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20084Q460 + (09:09:37, 14 December 2024)
- ML20084Q452 + (09:09:38, 14 December 2024)
- ML20084Q444 + (09:09:39, 14 December 2024)
- ML20084Q451 + (09:09:39, 14 December 2024)
- ML20084Q438 + (09:09:40, 14 December 2024)
- ML20084Q439 + (09:09:40, 14 December 2024)
- ML20084Q436 + (09:09:41, 14 December 2024)
- ML20084Q431 + (09:09:42, 14 December 2024)
- ML20084Q430 + (09:09:43, 14 December 2024)
- ML20084Q423 + (09:09:43, 14 December 2024)
- ML20084Q417 + (09:09:44, 14 December 2024)
- ML20084Q422 + (09:09:44, 14 December 2024)
- ML20084Q416 + (09:09:45, 14 December 2024)
- ML20084Q413 + (09:09:46, 14 December 2024)
- 05000298/LER-1984-006, :on 840418,offgas Stack Release Not Monitored as Required by Tech Specs.Caused by Technician Failure to Follow Approved Procedure.Plant Procedures Revised + (09:09:48, 14 December 2024)
- ML20084Q408 + (09:09:49, 14 December 2024)
- 05000249/LER-1976-001-01, During Weekly Turbine Surveillance Testing,Closure of Control Valve 2 Failed to Initiate Reactor Half Scram.Caused by Malfunctioning Solenoid Valve.Solenoid Replaced + (09:09:50, 14 December 2024)
- ML20084Q402 + (09:09:51, 14 December 2024)
- ML20084Q401 + (09:09:52, 14 December 2024)
- 05000281/LER-1984-009-01, :on 840415,reactor Trip Occurred as Result of Intermediate Range High Flux Trip.Caused by Spike on Range Detector NI-35.Emergency & Function Restoration Procedures Performed + (09:09:53, 14 December 2024)
- ML20084Q396 + (09:09:54, 14 December 2024)
- ML20084Q395 + (09:09:55, 14 December 2024)
- ML20084Q391 + (09:09:57, 14 December 2024)
- ML20084Q387 + (09:09:58, 14 December 2024)
- 05000265/LER-1976-009-01, /01L-01:on 760627,during Surveillance Test,Dual Indication for Drywell/Torus Vacuum Breaker AO 2-1601-33A Received.Caused by Failed Micro Switch Type BAG1-2RN Limit switch.W760726 Forwarding Ltr + (09:09:59, 14 December 2024)
- ML20084Q375 + (09:10:00, 14 December 2024)
- TXX-4168, Deficiency Rept SDAR-129 Re Error in Tolerances Used in Calibr of Adhesion Tester.Initially Reported on 840116. Investigation Incomplete.Next Rept Will Be Submitted by 840801 + (09:10:01, 14 December 2024)
- 05000254/LER-1976-010-03, /03L-0:on 760305,interlock Broken When Personnel Entered from Reactor Bldg to Turbine Bldg.Caused by Defective Latch & Frame.Mod Being processed.W/760402 Forwarding Ltr + (09:10:03, 14 December 2024)
- ML20084Q356 + (09:10:04, 14 December 2024)
- ML20084Q362 + (09:10:04, 14 December 2024)
- 05000265/LER-1976-010-03, /03L-0:on 760712,suppression Chamber Purge Valve AO 2-1601-56 Failed to Close During Surveillance Testing. Caused by Stuck Solenoid Valve SO 2-1601-65.Solenoid cleaned.W/760810 Forwarding Ltr + (09:10:06, 14 December 2024)
- ML20084Q353 + (09:10:07, 14 December 2024)
- ML20084Q351 + (09:10:08, 14 December 2024)
- ML20084Q349 + (09:10:08, 14 December 2024)
- ML20084Q343 + (09:10:09, 14 December 2024)
- AECM-84-0122, Forwards Amend 58 to Fsar.Amend Consists of Changes Associated W/Tech Spec Review program.NUREG-0737,Item I.A.2.1 Re Time Limit for Reactor Operators to Become Senior Reactor Operators Also Addressed + (09:10:10, 14 December 2024)
- 05000254/LER-1976-011-03, /03L-01:on 760314,temp of 153 F Reached on Outboard MSIV AO-1-203-20 Pilot Valve.Caused by MSIV Room Coolers Being Shut Off Sometime After Prestartup Check W/O Informing Shift engineer.W/760413 Forwarding Ltr + (09:10:11, 14 December 2024)
- ML20084Q337 + (09:10:12, 14 December 2024)
- TXX-4167, Interim Deficiency Rept SDAR-12D Re Discrepancy in Vendor Documentation of QA Inspector Eye Exam Records.Evaluation Continuing.Next Rept Will Be Submitted by 840629 + (09:10:13, 14 December 2024)
- ML20084Q333 + (09:10:14, 14 December 2024)
- ML20084Q325 + (09:10:15, 14 December 2024)
- ML20084Q323 + (09:10:16, 14 December 2024)
- 05000265/LER-1976-011-03, /03L-01:on 760717,four Drywell Pressure Switches Rendered Inoperable.Caused by Blocked Sensing Line.Line Blown Clear W/Instrument air.W/760820 Forwarding Ltr + (09:10:18, 14 December 2024)
- ML20084Q318 + (09:10:19, 14 December 2024)
- ML20084Q303 + (09:10:20, 14 December 2024)
- ML20084Q311 + (09:10:20, 14 December 2024)
- 05000254/LER-1976-012-03, /03L-0:on 760310,watertight Door on RHR Svc Water Vault 1B Exceeded Limits When Leak Rate Tested.Caused by Roughness on Knife Edge & Partially Dried Out Gasket.W/ 760409 Forwarding Ltr + (09:10:22, 14 December 2024)
- ML20084Q293 + (09:10:23, 14 December 2024)
- 05000265/LER-1976-012-01, /01T-0:on 760825,pressure Switch Ps 2-1001-90B Found Valved Out.Caused by Switch Being Left Isolated After Completion of Prior Month Surveilance testing.W/760924 Forwarding Ltr + (09:10:24, 14 December 2024)
- BECO-94-055, Informs That Beco Plans to Submit Analysis for Pilgrim Rv Being Prepared by External Engineering Svcs Vendor on or Before 941031,in Response to NRC 940511 Telcon Request That Beco Provide Docketed Date for Submitting Subj Analysis + (09:10:28, 14 December 2024)
- ML20084Q280 + (09:10:29, 14 December 2024)