Forwards Application to Amend License DPR-34,revising Tech Specs to Change Circulator speed-high Steam Trip Setting (Table 4.4-3).Change Would Increase Circulator Availability While Providing for Initiation of Protective Actions
ML20084Q422
Person / Time
Site: Fort Saint Vrain Xcel Energy icon.png
Issue date: 05/10/1984
From: Lee O
PUBLIC SERVICE CO. OF COLORADO
To: Jay Collins
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML20084Q425 List:
References
P-84137, TAC-55294, NUDOCS 8405210253
Download: ML20084Q422 (2)


Text

F h

PUBLIC SERVICE COMPANY OF COLORADO g P. O. BOX 840 DENVER, COLORADO 80201 OSCAR R. LEE 16805 WCR 19 1/2, Platteville, Colorado 80651 vtCE PRESIDENT May 10, 1984 Fort S+. Vrain Unit #1 P-84137 Mr. John T. Collins, Regional Administrator 3 ] g [EEiji'; ): .

Region IV s Nuclear Regulatory Commission 611 Ryan Plaza Drive NAY I 51984 Suite 1000 .__ ._W Arlington, TX 76011 Docket No. 50-267

SUBJECT:

Technical Specification Change to Circulator Overspeed Trip Setting

REFERENCES:

(1) P-84112 (Warembourg to Wagner, Dated April 16, 1984)

Dear Mr. Collins:

This letter is to propose a change to the Circulator Speed-High Steam trip setting listed in Table 4.4-3 of the Fort St. Vrain Technical Specification (Attachment 1). The proposed increase in trip setting would increase circulator availability while still providing for initiation of the necessary protective actions prior to the maximum credible overspeed condition or the actions prior to the maximum credible overspeed condition or the blade shedding safety limit.

This new setting would avoid unnecessary actuations of the circulator protective circuitry due to normal system transients at or near 100%

power operation.

/

7 O

$'MNON P

t \\

-L_

s

  • ^ * .

As evaluated in Attachment 2, the proposed change is deemed to involve no significant hazards considerations. Therefore, in accordance with 10 CFR 170, these changes are believed to be Fee Class III, and a check in the amount of $4,000.00 is enclosed.

If you have any questions, please contact Mr. Don Warembourg at (303) 785-2224.

Very truly yours, 7

. R. Lee Vice President Electric Production Attachments cc: A. J. Hazle, Colorado Department of Health ORL/djm O