ML20084Q353
| ML20084Q353 | |
| Person / Time | |
|---|---|
| Site: | Midland |
| Issue date: | 05/09/1984 |
| From: | Reichel N CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.) |
| To: | STONE & WEBSTER, INC. |
| References | |
| CSC-7732, NUDOCS 8405210224 | |
| Download: ML20084Q353 (11) | |
Text
,.
t CONSCMERS POWER COMPANY MIDLAND ENERGY CENTER Transmittal No:
CSC-7732
[
V E
Date: May 9, 1984 To:
Stone & Webster P O Box 1963
' Midland, MI 48640 Py t1CIPAL STAFF f1&NW Attached Is Partial Response To y/fA
' 2E--
A/fe l
\\
~
go
- !. ! \\
g Complete Response T oAO 3C3 O*-
i cCA AL f--
For Your Information gg
]
Fito iA4-l Other Descriptions i
L Tracked Information Item 072.
t i
(m,
?
V i
l b
h I
t l-l l
l l
i Signature: M
, 2, m, r.
]JGKeppler,;NRC R ion;III ;w/afs cc:
JJHarfisin',~NRC Region III w/a RJCcok, NRC Site w/a RAWells, MPQAD w/a h lI BHTeck, MEC w/a NIReichel, MEC w/n DDJohnson, MEC w/a l \\
8405210224 840509 MAy14j M '
~
PDR ADOCK 05000329 A
ITEM / HOLD POINT NOTIFICATION FORM Sheet 1 of n I
REM NUMBER HOLD POINi huMBER STONE S WEBSTER a, 7 3 CONSTRUCTION IMPLEMENTATION O TRACKED ACTION ITEM l
OVERVIEW g TRACKED INFORMATION ITEM MIDldND NUCLEAR PLANTJ.0. NO.14509 O TRACKEo RECOuMENDATION ITEM O UNTRACKED ITEM l REFERENCE (S) l ANSI N45.2 Section 7 O HOLD POINT NOTIFICATION
{
CONDITION DETAILS The following approved B&W NDE procedures lack. consistency in specifying the procedure, page and revision number as applicable.
A)
Procedure NDE PQ-RT - 200 d consist of 3 pages Page 1 of 3 reads: NDE-PQ-RT-200 Page 1 of 3 Revision 1 Page 2 of 3 reads: 9T-RT-200 Page 2 of 3 No Revision specified Page 3 of 3 reads: 9T-RT-200 Page 3 of 3 No Revision specified B)
Procedure NDE-PQ-RT-201 d consist of 3 pages Pages 2 of 3 and 3 of 3 lack procedure number and revision C)
Procedure NDE-PQ-RT-202 A consist of two pages Pages 1 & 2 lack page number
^ '
What action is being taken to resolve the identified O m l'O s>
8m inconsistencies?
ATTACHMENTS D ATE RESPONSE REO'D.
INITI R/DATE ltllTIATI APPROV ED/D ATE m(M or4-9e4 ///
ME/c F-//-f 4-23-84 s
J f
\\)
RESPONSE (SEE NOTE)
Attached Bechtel Letter BCCC-9287 dated April 30, 1984 has been reviewed by CPCo SMO and determined to provide a complete response to this item.
l (P AG E O YES NCTS)
NO ATTACHMENTS EST. CORRECTIVE ACTION RESPONDENT TITLE DATE
/vp '77/G2 ]
Md&,JzA sMa
" ' " " " " ^ ' '
- ESPONSE ACCEPTED DATE )
RESPONSE VERIFIED / CLOSED '
D' ATE NOTE - FOR TR ACKED ACTION ITEMS ONLY. EXFL AIN CLE ARLY OR REFERENCE ATTACHMENTS FOR:
- 1) CAUSE OF O BSERVED CONDITION 2) CORRECTIVE ACTION T AKEN 3) PREVENTIVE ACTION TAKEN (KA)
. ::tgf Bechtel Power Corporation
(
Post Office Box 2167 Midland. Micnigan 48640 April 30, 1984 Consumers Power Company P.O. Box 1963 Midland, Michigan 48640 7
l Attention:
D. L. Quamme Site Manager Midland Plant Units 1 & 2 Bechtel Job 7220 STONE & WEBSTER OVERVIEW ITEM N0. 072 BCCC-9287
Dear Mr. Quamme:
This is considered as Construction's final response to Stone and Webster Overview Item No. 072.
(~
(_,)/
Procedure NDE-PQ-RT-200 Revision 1, Page 2 of 3 and Page 3 of 3, have been annotated with PQ-RT-200 Revision 1.
Procedure NDE-PQ-RT-201 Revision 1, Page 2 'of 3 and Page 3 of 3, have been annotated with PQ-RT-201 Revision 1.
Procedure NDE-PQ-RT-202 Revision 0, Pages 1 and 2 have been page numbered.
If you have any questions, please contact John Russell at extension 7S94.
Very truly yours, 1
G. A. Hierze j
Site Man ger GAH/JER/ajd Attachments:
1)
NDE-PQ-RT-200, Rev. 1 2)
NDE-PQ-RT-201, Rev. 1 3)
NDE-PQ-RT-202, Rev. 0 cc:
N. Reichel.
(])
BABCOCK & WILCOX B&W CONSTRUCTION COMPANY NONDESTRUCTIVE EXAMINATION RADIOGRAPHIC PROCEDURE QUALIFICATION MATERI AL TYPE Carbon, Low Alloy & Stainless Steels MATERI AL THICKNESS
.150"
.150" through 3-1/2" MATERI AL THICKNESS RANGE CERTIFIED TYPE OF RADIATION SOURCE Iridium-192 PHYSICAL SIZE OF ISOTOPE SOURCE
.010 x.010 (effective source size.141)
MINIMUM SOURCE TO FILM DISTANCE See Attached Sketch FILM DISTANCE TO OBJECT Intimate contact Type 1, Dupont 45 FILM TYPE & BRAND
' " UMBER OF FILM IN CASSETTE Two FILM TO BE VIEWED Sincle l
TYPE & THICKNESS OF SCREENS & FILTERS.010 lead screens front and back.
i BLOCKING & MASKING IF USED None l
' GEOMETRIC ARRANGEMENTS FOR THE RADIOGRAPHS ISKETCH) See Attached Sketch.
ORIENTATION OF LOCATION MARKERS See Attached Sketch INTERN AL MARKERS None WELDING PROCESS Manual Gas Tungsten Arc and/or Shielded Metal Arc Welding e
/
'p%'
IDENTIFICATION:
APPROVED BY hw DATE
[
B&W CONSTRUCTid COMPANY
/
j NDE-PQ RT-200 WITNESSED BY DATE REV.
1 e
.orgm Ig
((
g, Page 1 of 3
A BABCOCK & WILCOX..
~
. PGE "
B&W CONSTRUCTION COMPANY
~
INSPECTION SKETCH
'....~.... :..
j SOURCE W20' i
I 1
l i
.g I
P EN ETRAMETERhMIM O*
S I
______l_______
4_
t L
i A
i i
uma amm em muu amm as as mYmm am em men muu ame um um me.no a mas mus.ame un'.smu.me]
i i
s FILM l
CASSETTE
~
l PIPE Df AMETER:.841 l
WALL THICKNESS:.150 l
SOURCE TO FILM DISTANCE: 12" t
PENETRAME l
1 1.
g o-F1LM CASSETTEN -
_w l
I
Subject:
RAD 10 GRAPHIC EXAMINATION OF c
"^
d CIRCUFERENTIAL BUTT WELDS U11NG IRlDIUM-192 R. C. SULZER 1
1 SUPPLEWENTS REPORT OF INSPECTION i
sketch No.
N/A W
N/A Number NDE-PO-RT-200, Rev. 1 vana
- )
e
u.
BABCOCK & WIL'CO'X -....'..
... _. " ~
'-'mg.
-.2-2.,,.
-; B&W CONSTRUCTIONCOMPANY - __ -
s
. INSPECTION SKETCH.....
O e
'50URCE
.e p2o l
l l
f i
(
x. i..
" ~ ~ '
~
~ ' ' '
~ '"
PENET'R'AMETER SHl'M ' -
.. ~ ~
.. _'.~... :...
~...;.
-- l i
g g
ah
.-w l
A.
l l
Q-su sus emlum as em/4 a O
ens aus m e mas sum.sme e m uma muk aus. m s mis ]me. ass me tsum es j
l I
g i
FILM CASSETTE t
t PIPE DIAMETER:.841 j
WALL THICKNESS:.150 l
SOURCE TO FILM DISTANCE: 12" f
O P2NETRAME>
...1
~.
_L 12 0 240' uma sum um uns um I
I FILM CASSETTE l
\\
l
Subject:
RADIOGRAPHIC EXAMINATION OF 3f3 W
I CIRCUMFERENTIAL BUTT WELDS USING IRIDIUM 192 R. C. SULIER mg SUPPLEMENTS REPORT OF INSPECTION N/A Number NDE-PO-RT-200, Rev. 1 N/A m
- ,_ m
'B ABCOCK & WILCOX B&W CONSTRUCTION COMPANY NONDESTRUCTIVE EXAMINATION RADIOGRAPHIC PROCEDURE QUALIFICATION Carbon, Low Alloy, & Stainless Steel M ATERI AL TY PE MATERIAL THICKNESS 2" thru 6",
inclusive M ATERI AL THICKNESS RANGE CERTIFIED 2" to Maximum to be Radiographed TYPE OF RADIATION SOURCE Cobalt 60 PHYSICAL SIZE OF ISOTOPE SOURCE
.125 Diameter Sphere MINIMUM SOURCE TO FILM DISTANCE 14" FILM DISTANCE TO CBJECT Intimate Contact i
FILM TYPE & BRAND Type 1, Dupont 55 Type II, Dupont 65
- ]
NUMBER OF FILM IN CASSETTE As recuired, two film min.
FILM TO BE VIEWED Single or composite, as required TYPE & THICKNESS OF SCREENS & FILTERS.010 lead screens, front and back BLOCKING & MASKING IF USED None GEOMETRIC ARRANGEMENTS FOR THE RADIOGRAPHS ISKETCH)
See Attached Sketch l
ORIENTATION OF LOCATION MARKERS See Attached Sketch INTERN AL MARKERS None WELDING PROCESS Submerged Arc Welding
/
b -k -7 APPROVED BY ATE
{')
saw CONSTRUCTION Y
w A/8./fiJdOATE h"h'7[
1 WITNESSED BY
)f7 REV*
A6 PRIZED INpCTOR Page 1 of 3
Tit,D10 CRAP!i!C U,YCUT REACTCR C00LAtlT PUlA?S 3
O 10, 421.0 o
- orrom wato e l
- e>
i 81LM W
r
,/j',w
- a..
l i
l The maximum geometric unsharpness for material thickness up to 4" is.027.
i l
x M
w
+
>+
X 1
L
\\
C-4 T
7J 0
s e
4 4 O
4 t-4 /0 gl1 Agg Page 2 of }
RADJCGRAPHiC LAYOUT REACTC}t CCOLANT PUMP 5 Tc. '.ysto @
30TTOM WELD 0
[
o 1
M i
F : t..w l
l
,,a
.w, t
i The maximum geometric unsharpness for material thickness up to 4" is.027.
6 9
~
b<
!?,.
- i y
[
x 4
~
b
\\
i
/
I i
n
, u l-ll g
[
dl t
1x k
l I
1 6
(
u i
l at
/
{
\\\\g..
\\
k.
/
/
\\
b t
./
'g j
4 s
\\
i N
zm i
i P
P
B&W CONSTRUCTION COMPANY NONDESTRUCTIVE EXAMINATION
. RADIOGRAPHIC PROCEDURE QUALIFICATION Carbon, Low Alloy & Stainless Steels MATERI AL TYPE
.300" to.425 MATERIAL THICKNESS
.300" through 3.500" MATERIAL THICKNESS RANGE CERTIFIED Iridium-192 TYPE OF RADIATION SOURCE
.100" x.100" (Effective source size.141)
PHYSICALSIZE OF ISOTOPE SOURCE MINIMUM SOURCE TO FILM DISTANCE 3.875" min.
4.250 max.
FILM DISTANCE TO OBJECT
.500" max.
Source to ebject 3.200" min.
Type 1, Kodak "M" FILM TYPE & BRAND DO NUMBER OF FILM IN CASSe.a i E l
I FILM TO BE V.EWED Single
.010" lead screens front & back TYPE & THICKNESS OF SCREENS &. FILTERS l
None BLOCKING & MASKING IF USED See attached sketch CEOMETRIC ARRANGEMENTS FOR THE RADIOGRAPHS (SKETCH)
See attached sketch ORIENTATION OF LOCATION MARK.ERS None INTERN AL MARKERS WELDING PROCESS. Manual Gas Tungston Arc and/or Shielded Metal Arc welding f
{
APPROVED BY DATE 6 - D 80 ONSTRUCTION CDMPANY l
l l
NDE.PQ-RT-202 WITNESSED BY D
W DATE
'I '
- D REV.
0 AUTHORIZED INSPECTOR w68529 Pogo A of
_~.....
h nrT--.mm.v ww-.,
.d......... _. _.
a
..~ <
.g / w s m n-
- r.....
_'..' '.,9 O.
- f '-
- M
..r
............'.. I NSP. ECTI ON SK ETCH
.w,
~-.1
. s, -s3 m t....
s
.9
/
......g...
- s af
.m
.,;.__................._.-..e...
....c
/
ource.
.y s..<.,.,i
..-.__.__./
./~q..
.. e s.
.,y j_...
.' w
~
.. +.
._.__s__-
7
__ w
.s.,
- g...
....,e.._.
._ s b.
..v
.1
.. c.
.. y %
........ f
.~.
....,.~
- . _... 2,
....,.___.y.
....; m.. ;_1 a
-n r
- .1
. ; _._ _.s.
I.._*.....
y
~ -
1
..e
,,i v.-. - -.
-. n L F1.1m. Casse.tte.-
. < m,
..Penetrameter.,.
..W V. and Shim.
g
- m.._.._,____g.
u
.,....g...
g,!
, 7. _
.,.,,s
..,.._:. i _. ;..,_;.
..... \\
.r.
.v.
_.\\
3.r
( 3 _ _...
l...%
l t
/
tW u.
....s.
si.
'.J
' Pen.etrameter_.
g s.and Shim s
I o
L......_._...
j l
I.. _.=
....._e.:._._
+.
j
._..s.
- s...
<~~ Eilm Cassette
... 'j W 2
1 e.
..s Ng
. Source. ; -
i --.. _
biect: Radiographic examination of gg Contract ircumferential butt velds joining pipe to nozzel with unequal O.D. using R. W. Shope Sketch by Iridtum-192 SUPPLEMENTS REPORT OF INSPECTION *
~
~
NDE-PQ-RT-202 Rev. O N/A m
N/A Number ska-m Pace 2 CC'