Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000413/LER-1991-029, :on 911126,discovered That Surveillance Requirement for Turbine Startup Pressure Switch Alarm Not Performed During Turbine Startups.Caused by Inappropriate Operator Actions.Procedure Revised + (06:43:41, 14 December 2024)
- 05000416/LER-1983-177-03, 1102 & 06,water Collected in Offgas Pretreatment Monitor,Resulting in Improper Flow Through Monitor.Caused by Accumulation of Condensation.Heat Tracing Installed on Piping + (06:43:44, 14 December 2024)
- ML20086P384 + (06:43:45, 14 December 2024)
- ML20086P375 + (06:43:46, 14 December 2024)
- 05000414/LER-1991-015-02, :on 911118,chemistry Sample Indicated That Refueling Water Storage Tank Boron Concentration Was Less than TS Requirement of 2,000 Ppm.Caused by Lack of Boration Flow Path.Fuel Loading Terminated + (06:43:47, 14 December 2024)
- ML20086P370 + (06:43:48, 14 December 2024)
- 05000250/LER-1984-004, :on 840104,auxiliary Feedwater Sys Periodic Test Initiated & Pump a Failed to Develop Required Flow. Caused by Misposition of Manual Governor Speed Control Knob. Knob Reset to Max Position + (06:43:50, 14 December 2024)
- ML20086P357 + (06:43:51, 14 December 2024)
- ML20086P359 + (06:43:51, 14 December 2024)
- ML20086P343 + (06:43:55, 14 December 2024)
- 3F1291-12, Provides Notice of Senior Operator Illness Described,Per 10CFR55.25.As Result of Illness Wm Marshall Unable to Perform Licensed Duties + (06:43:56, 14 December 2024)
- ML20086P336 + (06:43:56, 14 December 2024)
- ML20086P327 + (06:43:57, 14 December 2024)
- ML20086P328 + (06:43:57, 14 December 2024)
- 05000369/LER-1984-001-01, :on 840109,unauthorized Removal of Safety Injection,Main Feedwater & Component Cooling Sys Support/ Restraints Discovered.Support/Restraints Reinstalled, Repaired or Deleted as Appropriate + (06:43:59, 14 December 2024)
- ML20086P322 + (06:44:00, 14 December 2024)
- ML20086P324 + (06:44:00, 14 December 2024)
- ML20086P316 + (06:44:01, 14 December 2024)
- ML20086P315 + (06:44:02, 14 December 2024)
- ML20086P313 + (06:44:03, 14 December 2024)
- 05000424/LER-1991-012-02, :on 911118,discovered That Digital Rod Position Indication for Shutdown Bank A,Rod D-2 Stopped Moving, Resulting in Manual Actuation of Rps.Cause Undetermined. Addl Troubleshooting Will Be Performed + (06:44:04, 14 December 2024)
- ML20086P309 + (06:44:05, 14 December 2024)
- 05000424/LER-1991-011-02, :on 911118,automatic Auxiliary Feedwater Sys Actuation Occurred When Steam Generator 1 Reached lo-lo Level Setpoint.Caused by Personnel Error.Operator Counseled Re Need to Maintain Control + (06:44:10, 14 December 2024)
- ML20086P293 + (06:44:11, 14 December 2024)
- ML20086P292 + (06:44:12, 14 December 2024)
- 05000321/LER-1991-028, :on 911116,main Control Room Environ Control Sys Transferred to Pressurization Mode,Resulting in ESFAS Actuation.Caused by Personnel Error.Operator Counseled Re Lack of Attention to Detail + (06:44:13, 14 December 2024)
- ML20086P288 + (06:44:14, 14 December 2024)
- ML20086P284 + (06:44:15, 14 December 2024)
- ML20086P280 + (06:44:16, 14 December 2024)
- ML20086P279 + (06:44:16, 14 December 2024)
- 05000416/LER-1984-004, :on 840114,shutdown Cooling Suction Valve Isolated.Caused by Fuse Failure During Technician Panel Work.Fuse Replaced + (06:44:21, 14 December 2024)
- ML20086P273 + (06:44:22, 14 December 2024)
- ML20086P269 + (06:44:22, 14 December 2024)
- ML20086P268 + (06:44:23, 14 December 2024)
- ML20086P266 + (06:44:23, 14 December 2024)
- ML20086P264 + (06:44:24, 14 December 2024)
- ML20086P262 + (06:44:25, 14 December 2024)
- ML20086P256 + (06:44:28, 14 December 2024)
- ML20086P255 + (06:44:29, 14 December 2024)
- ML20086P252 + (06:44:29, 14 December 2024)
- NRC-91-0158, Forwards Nuclear Training Simulator Certification + (06:44:30, 14 December 2024)
- ML20086P228 + (06:44:31, 14 December 2024)
- PY-CEI-NRR-1423, Forwards ERDS Data Point Library & Plant Attribute Library Info Including List of Critical Safety Function Parameters for BWRs & Response to ERDS Survey Questionnaire + (06:44:31, 14 December 2024)
- ML20086P225 + (06:44:35, 14 December 2024)
- ML20086P221 + (06:44:38, 14 December 2024)
- ML20086P211 + (06:44:39, 14 December 2024)
- ML20086P216 + (06:44:39, 14 December 2024)
- ML20086P207 + (06:44:40, 14 December 2024)
- LD-91-065, Forwards Response to Request for Addl Info Re Std SAR Design Certification + (06:44:41, 14 December 2024)
- LD-91-066, Forwards Response to NRC 910805 Request for Addl in on CESSAR Design Certification + (06:44:42, 14 December 2024)
- ML20086P180 + (06:44:44, 14 December 2024)