- ML20086S598 + (06:30:09, 14 December 2024)
- ML20086S604 + (06:30:09, 14 December 2024)
- ML20086S594 + (06:30:10, 14 December 2024)
- ML20086S591 + (06:30:10, 14 December 2024)
- 05000281/LER-1976-002-03, /03L:on 760409,trip Valve TV-SS-201A Failed to Close When Operator Attempted to Close Valve from Control Panel.Vendor Contacted to Determine Cause.Valve Tested Satisfactorily W/O Prior Maint Activity + (06:30:12, 14 December 2024)
- 05000280/LER-1976-003-03, /03L:on 760326,ruptured Diaphragm in Valve 1-CH-85 Caused Exccessive Leakage of Borated Water.Caused by Normal Wear.Power Rampdown Commenced,Valve Repaired & Placed Back in Svc + (06:30:14, 14 December 2024)
- ML20086S586 + (06:30:15, 14 December 2024)
- ML20086S584 + (06:30:15, 14 December 2024)
- ML20086S582 + (06:30:16, 14 December 2024)
- 05000281/LER-1976-003-03, /03L:on 760412,condenser Outlet Valve MOV-CW-200A Would Not Operate.Caused by Water in Limit Switch Compartment & Motor.Motor & Limit Switch Repaired & Limit Switch Compartment water-proofed + (06:30:17, 14 December 2024)
- ML20086S579 + (06:30:18, 14 December 2024)
- ML20086S578 + (06:30:19, 14 December 2024)
- 05000280/LER-1976-004-03, /03L:on 760416,during Start Test,Emergency Diesel Generator 1 Damaged Due to Flooded Piston Cylinder 17. Caused by Crack in Cylinder Head.Engine Repaired + (06:30:23, 14 December 2024)
- ML20086S576 + (06:30:25, 14 December 2024)
- 05000281/LER-1976-004-03, /03L:on 760422,valve MOV-SW-202B Failed to Close When Cls Hi-Hi,Train B Signal Actuated During Testing.Caused by Corroded Contacts on Torque Switch.New Torque Switch Installed + (06:30:26, 14 December 2024)
- ML20086S574 + (06:30:27, 14 December 2024)
- ML20086S573 + (06:30:28, 14 December 2024)
- 05000281/LER-1976-005-03, /03L:on 760427,overall Integrated Containment Leakage Rate Found Greater than Acceptable Criterion.Cause Under Investigation.Repairs Will Be Made Per Investigation Results + (06:30:30, 14 December 2024)
- RC-95-0201, Forwards Submittal for Closure of GL 89-10, Safety-Related Motor-Operated Valve Testing & Surveillance + (06:30:31, 14 December 2024)
- 05000416/LER-1991-013-04, :on 911119,improperly Installed Conduit Seals Provided Flow Path for Rainwater to Enter Secondary Containment.Caused by Manhole Not Being Scaled Per Plant Design Drawing.Conduits Inspected + (06:30:33, 14 December 2024)
- ML20086S551 + (06:30:34, 14 December 2024)
- 05000281/LER-1976-006-03, /03L:on 760504,two of Three Pressurizer Level Transmitters Found to Have Out of Spec High Level Trip Setpoints.Caused by Normal Electronic Drift on LT-459 & 461. Transmitters Recalibr + (06:30:36, 14 December 2024)
- ML20086S517 + (06:30:37, 14 December 2024)
- ML20086S526 + (06:30:37, 14 December 2024)
- 05000280/LER-1976-007-03, /03L:on 760702,during Preparation for Start Test of Emergency Diesel Generator 1,water Observed Coming Out of Cylinder 19.Caused by Crack in Cylinder.Engine Repaired by Replacing Cylinder Head & Gasket + (06:30:39, 14 December 2024)
- 05000281/LER-1976-007-03, /03L:on 760607,refueling Water Chemical Addition Valve MOV-CS-202B Would Not Open Beyond mid-position Electrically.Caused by out-of-position Return Spring in Torque Switch.Switch Replaced + (06:30:41, 14 December 2024)
- 05000280/LER-1976-008-03, /03L:on 760702,safety Injection Accumulator B Indicated 1,928 Ppm Boron.Caused by Leaking Check Valves 1-SI-128 & 1-SI-130.Accumulator Recirculated in Raw Water Storage Tank to Increase Boron Concentration + (06:30:43, 14 December 2024)
- 05000281/LER-1976-008-03, /03L:on 760614,condenser Outlet Valve MOV-CW-200B Would Not Operate Electrically.Caused by Broken Off Valve Operator Worm Shaft Tripper Cam.Tripper Cam Replaced & Valve Tested & Returned to Svc + (06:30:45, 14 December 2024)
- 05000281/LER-1976-009-03, /03L:on 760615,valve Operator MOV-2862B Would Not Operate When Cycled by Console Control Switch.Caused by Actuation of Thermal Overloads in Breaker housing.Three- Point Adjustment Screws Loosened + (06:30:48, 14 December 2024)
- ML20086S491 + (06:30:49, 14 December 2024)
- ML20086S506 + (06:30:49, 14 December 2024)
- ML20086S468 + (06:30:50, 14 December 2024)
- ML20086S473 + (06:30:50, 14 December 2024)
- TXX-9518, Submits Response to Request for Addl Info on License Amend Request 94-022 Re Spent Fuel Storage Capacity Increase. Diskette Attached + (06:30:52, 14 December 2024)
- ML20086S464 + (06:30:52, 14 December 2024)
- ML20086S462 + (06:30:53, 14 December 2024)
- 05000000/LER-1950-237, Updated LER 50-237/01L:on 760406,unacceptable Ultrasonic Indication Found on Isolation Condenser safe-end.Caused by Cracks in safe-ends.Cracked safe-end Removed & Sent to Bmcl for Metallographic Analysis + (06:30:54, 14 December 2024)
- ML20086S451 + (06:30:56, 14 December 2024)
- ML20086S450 + (06:30:56, 14 December 2024)
- ML20086S449 + (06:30:57, 14 December 2024)
- 05000000/LER-1976-010-03, /03L:on 760723,during Start Testing of Emergency Diesel Generator 1,water Detected in Cylinder 7.Caused by Crack in Cylinder Head.Engine Repaired by Replacing Cylinder Head & Head Gasket + (06:30:58, 14 December 2024)
- ML20086S437 + (06:30:59, 14 December 2024)
- ML20086S426 + (06:31:00, 14 December 2024)
- ML20086S430 + (06:31:00, 14 December 2024)
- ML20086S424 + (06:31:01, 14 December 2024)
- ML20086S417 + (06:31:02, 14 December 2024)
- ML20086S420 + (06:31:02, 14 December 2024)
- ML20086S412 + (06:31:04, 14 December 2024)
- ML20086S416 + (06:31:04, 14 December 2024)
- ML20086S410 + (06:31:05, 14 December 2024)
- ML20086S407 + (06:31:06, 14 December 2024)