- ML20128P800 + (17:39:31, 12 December 2024)
- ML20128P799 + (17:39:32, 12 December 2024)
- ML20128P797 + (17:39:34, 12 December 2024)
- ML20128P795 + (17:39:35, 12 December 2024)
- ML20128P790 + (17:39:36, 12 December 2024)
- ML20128P789 + (17:39:37, 12 December 2024)
- ML20128P786 + (17:39:38, 12 December 2024)
- ML20128P785 + (17:39:39, 12 December 2024)
- ML20128P784 + (17:39:40, 12 December 2024)
- ML20128P780 + (17:39:41, 12 December 2024)
- ML20128P778 + (17:39:42, 12 December 2024)
- ML20128P777 + (17:39:43, 12 December 2024)
- ML20128P776 + (17:39:44, 12 December 2024)
- ML20128P774 + (17:39:45, 12 December 2024)
- 05000366/LER-1985-016, :on 850425,during Testing of Main Steam Safety Relief Valves,Four Valves Failed to Lift within Range Required by Tech Spec 3.4.2.1.Caused by Valve Pilot Setpoint Drift.Pilot Assemblies Refurbished & Retested + (17:39:48, 12 December 2024)
- ML20128P771 + (17:39:51, 12 December 2024)
- ML20128P770 + (17:39:52, 12 December 2024)
- ML20128P764 + (17:39:53, 12 December 2024)
- RBG-21-499, Interim Deficiency Rept DR-304 Re Potential Wall Thickness Problem w/SA106 Pipe Supplied by Phoenix Steel.Investigation Incomplete.Next Rept Will Be Submitted by 850726 + (17:39:54, 12 December 2024)
- ML20128P759 + (17:39:55, 12 December 2024)
- ML20128P758 + (17:39:56, 12 December 2024)
- ML20128P756 + (17:39:57, 12 December 2024)
- IR 05000483/1991007 + (17:40:00, 12 December 2024)
- ML20128P752 + (17:40:01, 12 December 2024)
- ML20128P751 + (17:40:02, 12 December 2024)
- ML20128P750 + (17:40:03, 12 December 2024)
- ML20128P749 + (17:40:04, 12 December 2024)
- PNO-IV-96-057, on 961016,fire in Empty Hot Cell Occurred. Caused by Spark from Arc Cutting Operation Outside Hot Cell Door.Matter Will Be Reviewed Further During Dec 1996 Insp. State of CA Informed + (17:40:04, 12 December 2024)
- ML20128P746 + (17:40:05, 12 December 2024)
- 05000295/LER-1985-023-04, :on 850617,14-day Review Requirement Exceeded by 1 Wk for Change to Surveillance Procedure IMWR-523 Re Loop F-523 Steam Generator Loop C Steam Flow Channel.Caused by Inadequate Review Procedures + (17:40:08, 12 December 2024)
- ML20128P744 + (17:40:09, 12 December 2024)
- ML20128P743 + (17:40:10, 12 December 2024)
- ML20128P742 + (17:40:11, 12 December 2024)
- ML20128P740 + (17:40:11, 12 December 2024)
- ML20128P739 + (17:40:12, 12 December 2024)
- ML20128P737 + (17:40:13, 12 December 2024)
- IR 05000295/1985021 + (17:40:15, 12 December 2024)
- ML20128P732 + (17:40:16, 12 December 2024)
- ML20128P731 + (17:40:16, 12 December 2024)
- IR 05000458/1991007 + (17:40:21, 12 December 2024)
- ML20128P727 + (17:40:22, 12 December 2024)
- ML20128P726 + (17:40:23, 12 December 2024)
- ML20128P724 + (17:40:24, 12 December 2024)
- IR 05000261/1991018 + (17:40:24, 12 December 2024)
- 05000304/LER-1985-010-06, :on 850422,required Weekly Functional Test of Boric Acid Transfer Pumps Missed.Caused by Personnel Oversight.Tracking of Required Weekly Surveillance & Daily Reviews Will Prevent Recurrence + (17:40:27, 12 December 2024)
- ML20128P721 + (17:40:28, 12 December 2024)
- ML20128P720 + (17:40:29, 12 December 2024)
- ML20128P718 + (17:40:29, 12 December 2024)
- ML20128P715 + (17:40:30, 12 December 2024)
- ML20128P712 + (17:40:31, 12 December 2024)
- 05000295/LER-1985-004, :on 850124,during Sump Valve Stroke Test PT-2B, Valves 1MOV-SI8812 a & B Failed to Reopen After Being Stroked Closed.Caused by Too Short Bypass Circuit Time.Time Reset & Tested + (17:40:34, 12 December 2024)