- 05000309/LER-1997-002, :on 970110,PCC/SCC Vacuum Relief Valve Testing Occurred.Cause Not Determined.Valves Are Currently in Process of Being Replaced by New Vacuum Breaker Valves.New Valves Will Be Included in IST Program + (23:56:54, 11 December 2024)
- ML20138K393 + (23:56:55, 11 December 2024)
- ML20138K391 + (23:56:55, 11 December 2024)
- ML20138K387 + (23:56:56, 11 December 2024)
- 05000354/LER-1997-001, :on 970103,EDG & Fire Suppression Sys Interaction Results in Plant Being in Condition Outside of Design Basis Occurred.Caused by Inadequate Analysis During Plant Construction.Training Will Be Completed + (23:56:58, 11 December 2024)
- 05000362/LER-1985-027-01, :on 850920,during Main Purge,Containment Airborne Radiation Monitor 3RE-7804 Reached Alarm Setpoint & Initiated Train a Containment Purge Isolation Sys.Caused by Movement of Stagnant Air Into Purge Exhaust + (23:57:00, 11 December 2024)
- ML20138K381 + (23:57:01, 11 December 2024)
- ML20138K376 + (23:57:02, 11 December 2024)
- ML20138K369 + (23:57:03, 11 December 2024)
- ML20138K367 + (23:57:05, 11 December 2024)
- ML20138K362 + (23:57:05, 11 December 2024)
- ML20138K359 + (23:57:06, 11 December 2024)
- ML20138K358 + (23:57:07, 11 December 2024)
- ML20138K357 + (23:57:07, 11 December 2024)
- 05000261/LER-1985-022-01, :on 850928,Exxon Nuclear Corp Informed Util of Error in Large Break LOCA Analysis Which Resulted in Peak Clad Temp Being Underpredicted.Reactor Power & High Flux Trip Setpoint Increased within New Limits + (23:57:09, 11 December 2024)
- ML20138K351 + (23:57:11, 11 December 2024)
- ML20138K340 + (23:57:12, 11 December 2024)
- ML20138K336 + (23:57:13, 11 December 2024)
- ML20138K323 + (23:57:14, 11 December 2024)
- ML20138K318 + (23:57:15, 11 December 2024)
- ML20138K312 + (23:57:16, 11 December 2024)
- ML20138K307 + (23:57:17, 11 December 2024)
- ML20138K306 + (23:57:18, 11 December 2024)
- ML20138K303 + (23:57:18, 11 December 2024)
- ML20138K301 + (23:57:19, 11 December 2024)
- ML20138K299 + (23:57:20, 11 December 2024)
- ML20138K294 + (23:57:21, 11 December 2024)
- ST-HL-AE-1547, Final Deficiency Rept Re Physical Separation of safety- Related Circuits on Integrated Head Package.Initially Reported on 851111.Condition Not Reportable Per 10CFR50.55(e) + (23:57:21, 11 December 2024)
- ML20138K293 + (23:57:22, 11 December 2024)
- ML20138K290 + (23:57:23, 11 December 2024)
- ML20138K286 + (23:57:24, 11 December 2024)
- ML20138K285 + (23:57:25, 11 December 2024)
- ML20138K283 + (23:57:26, 11 December 2024)
- ML20138K281 + (23:57:26, 11 December 2024)
- ML20138K279 + (23:57:27, 11 December 2024)
- ML20138K280 + (23:57:27, 11 December 2024)
- ML20138K278 + (23:57:28, 11 December 2024)
- 05000237/LER-1985-042-03, :on 851106,diesel Generator Day Tank Room Fire Door & Auxiliary Electrical Equipment Room West Fire Door Failed to Have 3 H Fire Rating Labels.Labels Cut Off During Installation.Doors Will Be Replaced + (23:57:30, 11 December 2024)
- ML20138K274 + (23:57:31, 11 December 2024)
- ML20138K273 + (23:57:31, 11 December 2024)
- ML20138K272 + (23:57:32, 11 December 2024)
- ML20138K270 + (23:57:33, 11 December 2024)
- ML20138K268 + (23:57:33, 11 December 2024)
- ML20138K264 + (23:57:34, 11 December 2024)
- ML20138K263 + (23:57:35, 11 December 2024)
- ML20138K262 + (23:57:36, 11 December 2024)
- ML20138K261 + (23:57:36, 11 December 2024)
- ML20138K260 + (23:57:37, 11 December 2024)
- ML20138K256 + (23:57:41, 11 December 2024)
- ML20138K255 + (23:57:42, 11 December 2024)
- TXX-4633, Part 21 & Deficiency Rept SDAR-202 Re Adequacy of Flux Mapping Sys Seal Table Restraints Under Seismic Loads. Westinghouse Reviewing Site Engineering Comments Re Mods to Sys.Review of Comments & Mods Will Be Completed by 860331 + (23:57:42, 11 December 2024)
- ML20138K252 + (23:57:43, 11 December 2024)