- ENS 40671 +
- 05000410/LER-1988-014, :on 880313,reactor Scram & ESF Actuations Occurred.Caused by Equipment Failure Due to Design Deficiency.Transmitter Replaced W/Upgraded Model & Temporary Mod Performed to Bypass Logic for Valves +
- ML17317A877 +
- ML17317A813 +
- ML17286A630 +
- ML20005G555 +
- 05000293/LER-1989-038, :on 891208,unplanned Automatic Reactor Protection Sys Scram Signal & Reactor Scram Occurred.Caused by False Low Reactor Vessel Water Level Signal.Local Level Indicators Satisfactorily Calibr +
- 05000311/LER-1993-007-01, :on 930528,all Four Rods of Control Rod Bank C, Group 1 Unexpectedly Dropped Fully Into Reactor Core.Caused by Degraded Signal from Regulation Board.Card Replaced & Firing Circuit Satisfactorily Tested +
- ML19343A419 +
- 05000346/LER-1979-095-03, /03L-0:on 790925,auxiliary Feed Pump Turbine Steam Inlet Valve MS106 on Sys 1 Lost Its Indication.Caused by Loose Lamp Retainer Ring Which Grounded & Blew Control Power Fuse.Ring Was Tightened & Fuse Replaced +
- ML19343B433 +
- ML19098B465 +
- ML20054F846 +
- 05000311/LER-1982-021, Forwards LER 82-021/03L-0.Detailed Event Analysis Encl +
- 05000311/LER-1982-081, Forwards LER 82-081/03L-0.Detailed Event Analysis Encl +
- 05000272/LER-1982-062, Forwards LER 82-062/03L-0.Detailed Event Analysis Encl +
- 05000267/LER-1982-024, Forwards LER 82-024/03X-2.Detailed Event Analysis Encl +
- RNP-RA/03-0006, Request for Technical Specifications Change Regarding Inoperable Analog Rod Position Indication for Control Rod H-10 +
- NL-02-134, September 2002 Monthly Operating Report for Indian Point Unit 2 +
- ML20058P166 +
- ML20086G160 +
- ML20084H251 +
- ML20082C748 +
- ML20079M246 +
- ML20073E718 +
- ML20100L265 +
- ML20106E576 +
- ML20108A063 +
- ML20106J426 +
- ML20148E139 +
- ML20154L570 +
- ML20153C476 +
- ML20151X351 +
- IR 05000293/1997011 +
- ML20203D610 +
- ML20214F347 +
- ML20214B838 +
- ML20238E809 +
- ML20238A388 +
- ML20237J815 +
- ML20237J030 +
- ML20236Q112 +
- IR 05000341/1987024 +
- ML20215F572 +
- ML20209G093 +
- BSEP-88-1040, Forwards Supplemental Response to Violations Noted in Insp Repts 50-324/88-21 & 50-325/88-21.Corrective Actions:Second Independent Review of Skid Sys Initiated W/Emphasis on Issue of Addressing Qualification of Passive Components +
- BSEP-88-0881, Responds to NRC Ltr Re Violations Noted in Insp Repts 50-324/88-21 & 50-325/88-21.Corrective Actions:Reviews of Skid Sys Initiated,Unit 2 Splices Replaced,Protective Fuses Installed & Refs Incorporated Into Preventative Maint Route +
- 05000368/LER-1989-016-01, :on 890903 & 18,continuous Fire Watch to Monitor Nonfunctional Fire Barriers Removed Due to High Airborne Activity.Caused by Failure to Establish Contingencies.Tech Spec Change Issued +
- 05000352/LER-1989-014, :on 890216,isolation of Refuel Floor Secondary Containment & Initiation of Standby Gas Treatment Sys,Esf Occurred.Caused by Boiler Malfunction.Auxiliary Operator at Auxiliary Boiler Encl Restored Three Boilers +
- 05000382/LER-1988-026, :on 881028,mgt Informed That Wrong Piping Class Tubing Installed for Boric Acid Makeup Tank Level Indicators.Caused by Personnel Error.Safety Evaluation Program Being Reviewed for Enhancements +