- ML20246B203 + (ML20246B203)
- 05000458/LER-1989-012, :on 890325,ESF Isolation Occurred for RWCU Main Steamline Drains & RHR Shutdown Cooling Sys.Caused by Loss of Power to Div II Isolation Logic When Breaker Opened. Breaker Reclosed + (ML20246B208)
- AECM-89-0153, Monthly Operating Rept for Jul 1989 for Grand Gulf Nuclear Station Unit 1 + (ML20246B211)
- ML20246B212 + (ML20246B212)
- 05000293/LER-1989-023, :on 890718,manually Initiated Reactor Protection Sys Scram Signal & Reactor Scram Occurred, Resulting in turbine-generator Trip & Transfer of Electrical Loads.Procedure Re Air Ejector Revised + (ML20246B214)
- 05000423/LER-1989-017, :on 890718,motor-operated Isolation Valve for Containment Recirculation Spray Header Inoperable for 27 H. on 890717,dual Position Indication Observed in Control Board.Caused by Inadequate Guidance + (ML20246B219)
- ML20246B221 + (ML20246B221)
- ML20246B227 + (ML20246B227)
- JAFP-89-0586, Monthly Operating Rept for Jul 1989 for Ja Fitzpatrick Nuclear Power Plant + (ML20246B230)
- ML20246B232 + (ML20246B232)
- ML20246B234 + (ML20246B234)
- ML20246B235 + (ML20246B235)
- ML20246B239 + (ML20246B239)
- PY-CEI-NRR-1050, Monthly Operating Rept for Jul 1989 for Perry Nuclear Power Station Unit 1 + (ML20246B242)
- ML20246B243 + (ML20246B243)
- IR 05000348/1989012 + (ML20246B244)
- ML20246B250 + (ML20246B250)
- ML20246B257 + (ML20246B257)
- ML20246B267 + (ML20246B267)
- ML20246B269 + (ML20246B269)
- ML20246B270 + (ML20246B270)
- ML20246B271 + (ML20246B271)
- 05000259/LER-1989-003-01, :on 890131,determined That Original Design of Suppression Pool Vacuum Relief Sys Does Not Meet Single Failure,Double Isolation Design Criteria.Caused by Design Error.Design Will Be Modified + (ML20246B274)
- ML20246B280 + (ML20246B280)
- ML20246B283 + (ML20246B283)
- ML20246B287 + (ML20246B287)
- NL-89-598, Monthly Operating Rept for Jul 1989 for Rancho Seco Nuclear Generating Station + (ML20246B288)
- ML20246B289 + (ML20246B289)
- ML20246B293 + (ML20246B293)
- 05000293/LER-1989-013, :on 890324,HPCI Sys Became Inoperable During Operability Surveillance Test.Caused by Turbine Steam Supply motor-operated Valve Not Opening Due to Two Loose Screws Causing Damage to Valve Operator Internals + (ML20246B297)
- ML20246B298 + (ML20246B298)
- ML20246B303 + (ML20246B303)
- PNO-IV-89-044, on 890628,pressure in Waste Gas Receiver a Decreased from 250 Psig & Pressure in Receiver a Decreased from 60 to 50 Psig.Caused by Erroneous Valve Lineup.Plant Stack Monitors Did Not Alarm + (ML20246B309)
- ML20246B310 + (ML20246B310)
- 0CAN068913, Advises That Util Developing Appropriate Tech Spec for Inadequate Core Cooling Instrumentation Following Safety Review Committee Meeting on 890808,per NRC 890323 Request + (ML20246B312)
- ML20246B316 + (ML20246B316)
- ML20246B320 + (ML20246B320)
- ML20246B321 + (ML20246B321)
- IR 05000445/1989037 + (ML20246B327)
- ML20246B330 + (ML20246B330)
- ML20246B333 + (ML20246B333)
- ML20246B335 + (ML20246B335)
- ML20246B338 + (ML20246B338)
- B13224, Forwards Request for Schedular Exemption from Requirements of 10CFR50,App J,Sections III.A.6.(b),III.D.2(a) & III.D.3. Exemptions Will Provide Relief from Requirements for Penalty Type a Test Intervals During 1989 Refueling Outage + (ML20246B341)
- ML20246B345 + (ML20246B345)
- ML20246B346 + (ML20246B346)
- 05000328/LER-1989-007-03, :on 890601,discovered Inconsistency in Reactor Coolant Pump Manual Dc Control Power Transfer Switch Positions.Caused by Mislabeling of Switch Position.Proper Labeling Completed + (ML20246B356)
- ML20246B364 + (ML20246B364)
- ML20246B369 + (ML20246B369)
- ML20246B373 + (ML20246B373)