ML20246B232
| ML20246B232 | |
| Person / Time | |
|---|---|
| Issue date: | 06/20/1989 |
| From: | Berlinger C Office of Nuclear Reactor Regulation |
| To: | Green W INSTITUTE OF NUCLEAR POWER OPERATIONS |
| References | |
| NUDOCS 8907070251 | |
| Download: ML20246B232 (5) | |
Text
_ _ _ - - _ _ _ _ _ _ _ _ _ - - _
.s June 20, 1989 Mr. Wade Green Institute of Nuclear Power Corporation Suite 1500, 1100 Circle 75 Parkway Atlanta, Georgia 30339-3064 j
Dear Mr. Green:
Enclosed for your information is our bi-weekly listing of generic communi-cations being considered or under development by the NRC staff. These include Bulletins (type coded BL on the list), Information Notices (IN) and Generic Letters (GL). Temporary Instructions, that cover the special NRC inspection effort resulting from certain generic communications, are listed with the type code TI. This listing includes all proposed generic communications that had been reported to us by June 15, 1989.
Sincerely, HI Carl H. Berlinger, Chief Generic Communications Branch Division of Operational Events Assessment Office of Nuclear Reactor Regulation
Enclosure:
As stated DISTRIBUTION w/ enclosure:
JLieberman, OE All NRC Division Directors All NRC Branch Chiefs CERossi, NRR RFraley, ACRS CHBerlinger, NRR J0Thoma, NRR OGCB members PDR Central? Files DCS DOEA R/F 0GCB R/F DKirkpatrick, R/F SRichardson, DOE gro3
(
N OGCB:00EA:NRR C/0GCB:DOEA:NRR
- kt-J1g) i DCKirkpatrick CHBerlinger 6/20/89 0 7 6/JO/89
'.,l f !
/
8907070251 890620 b5IC k{.] (({ [)) ],}f pdc l
I t
Page No.
1 06/15/89 PROPOSED GENERIC COMMUNICATIONS IN PREPARATION WITHIN THE NRC TP ORIGIN.
SUBJECT CONTACT PHONE ISSUE OFFICE DATE IN NRR/DRIS ENVIRONMENTAL QUALIFICATION OF Steve (301) 08/03/89 RVIB LIMITOROUE MOV ACTUATOR Alexander 492-0995 1
TERMINAL BLOCKS & MARATHON 1600 TERMINAL BLOCKS IN NRR/ DEST ERRORS IN CALIBRATION OF Joe Joyce (301) 10/31/89 SICB LEAD / LAG AND RATE CIRCUITS IN 492-3265 REACTOR PROTECTION SYSTEMS.
GL RES/DE SAFETY RELATED MOTOR OPERATED Owen (301) 07/01/89 EIB VALVE TESTING AND INSPECTION Rothberg 492-3424 GL NRR/DOEA CHANGE IN FORMAT FOR NRC Vernon (301) 10/01/89 OGCB GENERIC COMMUNICATIONS Hodge 492-1169 GL NRR/ DEST SUPPLEMENT TO GENERIC LETTER Shou-Nien (301) 07/03/89 j
EMEB 87-11 DEALING WITH ARBITRARY Hou 492-0904 INTERMEDIATE PIPE RUPTURE REQUIREMENTS GL AEDD LICENSEE COMM7TMENTS FOR John (301) 07/18/89 EMERGENCY RESPONSE DATA SYSTEM Jolicoeur 492-4155 (ERDS) IMPLEMENTATION GL NRr</ DEST NRR RECOMMENDATION ON ISI OF Chen P.
Tan (301) 06/30/89 CSGB MARK I & II STEEL 492-0829 CONTAINMENTS, REFUELING CAVITIES & ASSOC DRAINAGE SYS GL NRR/ DEST RESOLUTION OF GENERIC ISSUE Om P.
(301) 07/31/89 SELB B-56, DIESE;. RELI ABILITY Chopra 492-0835 GL NRR/DOEA LINE ITEM TECHNICAL Tom Dunning (301) 10/01/89 OTSB SPECIFICATION IMPROVEMENT -
492-1189 REMOVAL OF COMPONENT LISTS IN NRR/DRIS INADEQUATE FIRE DAMPER Joe (301) 09/15/89 VIB OPERABILITY TESTS UNDER AIR Petrosino 492-0979 FLOW CONDITIONS IN NRR/DRIS POTENTIAL MANUFACTURER DEFECTS Joe (301) 07/01/89 VID IN CUTLER HAMMER E-30 SWITCHES Petrosino 492-0979 MANUFACTURED PRIOR TO A CERTAIN DATE GL NRR/ DEST MINIMUM EDGE DISTANCE FOR John Ma (301) 10/31/89 ESGB INSTALLATION OF ANCHORS IN 492-1376 CONCRETE
)
i
,Page'No.
2 06/15/89 PROPOSED GENERIC COMMUNICATIONS IN PREPARATION WITHIN THE NRC TP ORIGIN.
SUBJECT CONTACT PHONE ISSUE OFFICE DATE-IN AEOD THE REPORTING OF SAFETY VALVE Mary S.
(301) 07/01/89 AND SAFETY-RELIEF VALVE EVENTS Wegner 492-7818 PURSUANT TO 10 CFR 50.73 GL NRR/DOEA VOLUNTARY ENTRY INTO TECHNICAL Calvin Moon (301) 07/15/89 OTSB SPECIFICATION 3.0.3 492-3136 GL RES/IEB RESOLUTION OF: GI/70, PORV AND R Kirkwood (301) 09/01/89 84 RPSIB BLOCK VALVE RELIABILITY, AND 492-3928 GI/94, ADDITIONAL LOW TEMP E Throm (301)
DVERPRESS PROTECTION FOR LWRS 492-3911 TI NRR/ DEST INSPECTION OF IMPLEMENTATION Ted (301) 11/01/89 EMEB OF GENERIC LETTER TO EXTEND Sulli van 492-0901 IED 85-03 "MOV COMMON MODE FAILURES DURING PLANT TRANSIENTS TI NRR/ DEST INSPECTION OF COMPLIANCE WITH Mike McCoy (301) 08/01/69 SRXB BULLETIN 88-04:
492-0880
" SAFETY-RELATED PUMP LOSS" BL NRR/ DEST INTERGRANULAR STRESS CORR Dave (301) 06/19/89 EMTB CRACKING OF HIGH-HARDNESS Sellers 492-0930 STUDS IN ANCHOR DARLING S350W SWING CHECK VALVES OR SIMILAR VALVES GL NRR/DOEA REMOVAL OF 3.25 LIMITATION OF Tom Dunning (301) 07/01/89 OSTB SPEC 4.0.2 FOR REFUELING 492-1189 SURVEILLANCE GL NRR/DOEA SERVICE WATER SYSTEM PROBLEMS Vernon (301) 07/01/89 OGCB AFFECTING SAFETY-RELATED Hodge 492-1169 EQUIPMENT IN REGION FAILURE OF LIMITOROUE VALVE John (312) 07/01/89
)
III OPERATOR HOUSINGS Harrison 790-5635 IN NRR/DDEA OPERATING EXPERIENCE FEEDBACK Vernon (301) 07/01/89 OGCB Hodge 492-1169 IN NRR/ DEST INOPERABILITY OF TURBINE J.
Wermiel (301) 07/03/89 SPLB DRIVEN AUXILIARY FEEDWATER 492-0870 PUMP WHEN ONE OF TWO PARALLEL STEAM SUPPLY VALVES IS CLOSED IN NRR/DRIS EVALUATION OF INSTRUMENT SET S.
V.
(301) 08/01/89 RSIB POINTS DURING MODIFICATIONS Athavale 492-0974 I
i i
l l.
Pago'No.
3 06/15/89 PROPOSED GENERIC COMMUNICATIONS IN PREPARATION WITHIN THE NRC TP ORIGIN.
SUBJECT CONTACT PHONE ISSUE OFFICE DATE GL NRR/ DEST CONTROL ROOM HABITABILITY Charles (301) 07/15/89 SPLB SYSTEMS Nichols 492-0854 IN NRR/DOEA CONTAINMENT ISOLATION Jerry (301) 07/01/89 OEAB DEFICIENCY Carter 492-1194 IN NRR/DOEA DIESEL GENERATOR FUEL DIL Vernon (301) 07/01/89 OGCB O'(IDATION Hodge 492-1169 BL NRR/DOEA NRC BULLETIN 88-10 SUPPLEMENT J.
Guillen (301) 06/23/89 OGCB 1: NONCONFORMING MOLDED-CASE 492-1170 CIRCUIT BREAKERS GL NRR/DOEA LINE-ITEM TECH SPEC Tom Dunning (301) 07/01/89 OTSB IMPROVEMENT - ALT REQUIREMENTS 492-1189 FOR FUEL ASSEMBLIES IN DESIGN FEATURE SECTION OF TECH SPECS GL NRR/DREP ACCIDENT MANAGEMENT STRATEGIES R.
Palla (301) 10/15/89 PRAB FOR CONSIDERATION IN IPE 492-1076 PROCESS - 10 CFR 50.54 BL NRR/ DEST EVALUATION OF HAZARDS Frank J.
(301) 07/03/89 ECEB ASSOCIATED WITH HYDROGEN USED Witt 492-0823 IN NUCLEAR POWER PLANTS IN REG V INGERSOLL-RAND AIR START Don (301) 06/29/89 MOTORS USED ON DIESEL Kirkpatrick 492-1152 GERERATORS IN NRR/ DEST GUIDANCE ON TEMPORARY REPAIR Frank J.
(301) 07/03/89 ECEB OF SERVICE WATER SYSTEM Witt 492-0823 I
COMPONENTS IN NRR/DRIS INADEOUATE POST MODIFICATION S.
V.
(301) 08/01/89 l
RSIB TESTING Athaval e 492-0974 IN NRR/DRIS INADEQUATE CONTROL OF S.
V.
(301) 09/01/89 RSIB TEMPORARY MODIFICATIONS ON Athaval e 492-0974 SAFETY RELATED SYSTEMS IN NRR/DRIS QUESTIONABLE CERTIFICATION OF Ray (301) 07/01/89 RVIB MATERIAL SUPPLIED TO THE Cilimberg 492-3220 j
DEFENSE DEPARTMENT l
IN NRR/DOEA SUPPLEMENT 1 TO INFORMATION P.
Kadambi (301) 07/01/89 OGCB NOTICE 89-22: QUESTIONABLE 492-1153 CERTIFICATION OF FASTENERS j
i
i,t..'...
,./Pcqn'No.
4 i.
..s.
06/15/89 PROPOSED GENERIC COMMUNICATIONS IN PREPARATION WITHIN THE NRC
.TP ORIGIN.
SUBJECT' CONTACT.
PHONE ISSUE OFFICE DATE IN NRR/DOEA POTENTIAL OVERPRESSURIZATION Walton (301)
'06/23/89
.OEAB OF. COMPONENT COOLING WATER' Jensen
'492-1190 SYSTEM FROM THERMAL BARRIER TUBING FAILURE'AT SURRY l,
GL.RES/DSIR ENEW3 RESOSUTION OF GENERIC
' Andrew (301) 06/30/89.
IEB.
ISSUE 101 - BOILING WATER S:ukiewicz 492-3914 REACTOR WATER LEVEL REDUNDANCY 4
I
___a