Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000295/LER-1989-010-03, :on 890711,unmarked Jumper Simulated Open Signal on Turbine Stop Valve,Causing Train a Reactor Trip. Caused by Not Properly Removing test-related Jumper After Testing.Testing Procedures Revised + (ML20245G324)
- ML20245G325 + (ML20245G325)
- ML20245G326 + (ML20245G326)
- IR 05000259/1987037 + (ML20245G330)
- ML20245G331 + (ML20245G331)
- ML20245G332 + (ML20245G332)
- ML20245G333 + (ML20245G333)
- 05000456/LER-1987-057, :on 871009,as Throttle Valve 2 Being Cycled, MW Output Became Erratic Resulting in Reactor Trip.Root Cause Indeterminate.Temporary Instrumentation Installed on Sensing Line of Turbine Impulse Transmitter + (ML20245G338)
- ML20245G341 + (ML20245G341)
- ML20245G348 + (ML20245G348)
- 05000219/LER-1989-015, :on 890518,reactor Automatically Shut Down Due to Trip of Main Turbine Generator.Caused by Personnel Error. Administrative Controls Implemented & Operators Briefed on Need to Use All Available Indications + (ML20245G351)
- ML20245G355 + (ML20245G355)
- ML20245G358 + (ML20245G358)
- ML20245G359 + (ML20245G359)
- 05000254/LER-1988-011-11, :on 880625,deviation Meter on RCIC Flow Controller Found to Be Indicating Full Pump Flow While Sys Was Off.Caused by Poor Electrical Contact in Controller Plug Connection.Connector Cleaned + (ML20245G365)
- IR 05000293/1982016 + (ML20245G369)
- ML20245G372 + (ML20245G372)
- ML20245G375 + (ML20245G375)
- ML20245G380 + (ML20245G380)
- ML20245G384 + (ML20245G384)
- ML20245G387 + (ML20245G387)
- ML20245G388 + (ML20245G388)
- BECO-89-084, Forwards Addl Info Re 880804 Response to Generic Ltr 88-01 Concerning NRC Position on IGSCC in BWR Austenitic Stainless Steel Piping,Per NRC 890331 Request + (ML20245G389)
- ML20245G391 + (ML20245G391)
- ML20245G392 + (ML20245G392)
- ML20245G393 + (ML20245G393)
- ML20245G395 + (ML20245G395)
- 05000265/LER-1988-022-05, :on 880531 & 0601,loss of Chimney Monitors Occurred When Power Supply Deenergized for Maint.Caused by Procedure Inadequacies Since Ref Documents Did Not Clearly Identified Affected Equipment + (ML20245G396)
- 05000455/LER-1989-005-09, :on 890523,feedwater Isolation Occurred from Reactor Trip P-4 Signal Generated While Racking in Reactor Trip Breaker.Cause of Event Could Not Be Identified.Caution Placed on Reactor Trip Breaker Cubicle + (ML20245G398)
- ML20245G399 + (ML20245G399)
- ML20245G401 + (ML20245G401)
- ML20245G403 + (ML20245G403)
- ML20245G404 + (ML20245G404)
- ML20245G409 + (ML20245G409)
- ML20245G410 + (ML20245G410)
- ML20245G411 + (ML20245G411)
- ML20245G413 + (ML20245G413)
- ML20245G416 + (ML20245G416)
- ML20245G418 + (ML20245G418)
- ML20245G420 + (ML20245G420)
- 05000304/LER-1988-015-09, :on 881219,operator Noticed That Auxiliary Feedwater Pump Headers Not Split,As Required by Tech Specs Due to Inoperable Pump.Caused by Deficiency in Plant Heatup Procedure.Procedure Revised + (ML20245G421)
- IA-89-341, Final Response to FOIA Request for Documents.No Agency Records Subj to Request Located.Confirms 890811 Telcon W/ L Robinson,Informing Recipient That NRC Has No Regulatory Authority Over Subjs of Request + (ML20245G422)
- ML20245G422 + (ML20245G422)
- ML20245G426 + (ML20245G426)
- ML20245G428 + (ML20245G428)
- ML20245G430 + (ML20245G430)
- ML20245G431 + (ML20245G431)
- ML20245G434 + (ML20245G434)
- ML20245G436 + (ML20245G436)
- ML20245G437 + (ML20245G437)
- 05000352/LER-1989-037, :on 890525 & 26,two Nuclear Steam Supply Shutoff Sys Group VI a & B Isolations & Initiations of Standby Gas Treatment Sys Fan & ESF Occurred.Cause Undetermined.Isolation Reset.Relay Replaced + (ML20245G439)