,__.

CffiCicL/

Jili}3 M System Energy Resources, Inc.

ATTN: Mr. W. T. Cottle, Vice President Nuclear Operations P. O. Box 23054 Jackson, MS 39205 Gentlemen:

SUBJEC T:

DOCKET N0. 50-416 As part of the NRC Confirmatory Measurements Program, liquid samples spiked with radionuclides will be sent to the Grand Gulf facility for radiochemical analyses. These samples are to be analyzed for tritium, iron-55, strontium-89, and strontium-90 in accordance with your approved procedures for analysis of liquid waste samples, if routine analyses of this type are normally performed by a vendor, th's vendor should be used to analyze the spiked samples.

The spiked samples, with instructions, will be sent under separate cover from the Department of Energy's Radiological and Environmental Sciences Laboratory, within approximately 30 days.

We request that the analyses be completed as soon as practicable, but no later than 60 days from receipt of the samples.

Results should be sent to:

V. S.

Nuclear Regulatory Commission, ATTN: Mr. D. M. Collins.

Our evaluation of your results will be discussed with your staff and transmitted in a letter.

Spiked samples will be sent to you on an annual basic as part of our routine inspection program.

If you have any questions regarding this program, please contact Mr. Collins at 404-331-5586, or Ms. Adamovitz at 404-331-4774.

Sincerely, Original Slybd By 4 M.Collias Douglas M. Collins, Chief Emergency Preparedness and Radiological Protection Branch Division of Radiation Safety and Safeguards cc:

(See page 2) 8906290121 890613 PDR ADOCK 05000416 3g P

PNu p

- e_ _ _ __a

f System Energy Resources, Inc.

2 j

i cc:

T. H. Cloninger, Vice President, Nuclear Engineering and Support i

C. R. Hutchinson, GGNS General Manager j

J. G. Cesare, Director, Nuclear Licensing R. T. Lally, Manager of Quality Assurance Middle South Utilities System Services, Inc.

R. B. McGehee, Csquire Wise, Carter, Child, Steen and Caraway N. S. Reynolds, Esquire Bishop, Cook, Purcell & Reynolds R. W. Jackson, Project Engineer G. O. Smith, Plant Chemist State of Mississippi bec: NRC Resident Inspector L. Kintner, NRR Document Control Desk 4

i 1

R RII DSeymour SAdamovitz FCantrell 6b./B9 6/12./89 6/ /89