Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20236K351 + (ML20236K351)
- 05000338/LER-1987-015, :on 870629,reactor Tripped Due to hi-hi Level in 5A Feedwater Heater.Caused by Improper Valve line-up Due to Failure to Follow Administrative Controls for Hanging & Removing Danger Tags.Procedures Revised + (ML20236K352)
- ML20236K353 + (ML20236K353)
- TXX-6618, Interim Deficiency Rept CP-86-52 Re Splice/Connections Used for Cable Trays.Initially Reported on 860429.Evaluation Continuing.Next Rept Expected by 870903 + (ML20236K355)
- ML20236K357 + (ML20236K357)
- ML20236K358 + (ML20236K358)
- ML20236K359 + (ML20236K359)
- ML20236K360 + (ML20236K360)
- ML20236K361 + (ML20236K361)
- ML20236K363 + (ML20236K363)
- ML20236K366 + (ML20236K366)
- ML20236K367 + (ML20236K367)
- ML20236K371 + (ML20236K371)
- ML20236K375 + (ML20236K375)
- ML20236K376 + (ML20236K376)
- ML20236K377 + (ML20236K377)
- ML20236K378 + (ML20236K378)
- ML20236K380 + (ML20236K380)
- ML20236K384 + (ML20236K384)
- ML20236K385 + (ML20236K385)
- ML20236K386 + (ML20236K386)
- BECO-87-173, Updates Info Provided in Re Inservice Insp Exams. NRC Should Note That Insp Discussed on 861212,when Performed,Will Complete First Insp Period of Second Ten Yr Inservice Insp Interval.Supporting Info Encl + (ML20236K387)
- ML20236K389 + (ML20236K389)
- NOC-AE-000213, Informs of Planned Long Term Corrective Actions for Performance During Each Units Next Refueling Outage to Prevent Recurrence of Main Steam Safety Valve Inoperability + (ML20236K390)
- ML20236K391 + (ML20236K391)
- ML20236K392 + (ML20236K392)
- ML20236K393 + (ML20236K393)
- ML20236K395 + (ML20236K395)
- ML20236K396 + (ML20236K396)
- ML20236K397 + (ML20236K397)
- ML20236K398 + (ML20236K398)
- ML20236K399 + (ML20236K399)
- RBG-26890, Forwards Review Results Re Issue on Security Computer & Mux Loop Communications.Addl Investigation Required to Adequately Determine Permanent Solution to Computer Power Circuitry + (ML20236K400)
- ML20236K402 + (ML20236K402)
- ML20236K405 + (ML20236K405)
- ML20236K406 + (ML20236K406)
- ML20236K409 + (ML20236K409)
- ML20236K410 + (ML20236K410)
- NOC-AE-000209, Forwards non-proprietary & Proprietary Response to NRC 980408 & 0515 Ltrs Re Proposed Amend to TS Sections 2.1,2.2 & 3/4.2.5 for Alternate Operations W/Reduced Measured RCS Flow.Proprietary Info Withheld Per 10CFR2.790(b)(4) + (ML20236K411)
- ML20236K413 + (ML20236K413)
- ML20236K414 + (ML20236K414)
- ML20236K415 + (ML20236K415)
- IR 05000073/1987001 + (ML20236K416)
- ML20236K417 + (ML20236K417)
- ML20236K418 + (ML20236K418)
- ML20236K419 + (ML20236K419)
- ML20236K422 + (ML20236K422)
- ML20236K423 + (ML20236K423)
- ML20236K425 + (ML20236K425)
- ML20236K427 + (ML20236K427)
- 05000352/LER-1998-013, :on 841026,failed to Meet Max Travel Distance Limitation & Guidance for Class a Extinguisher Replacement W/Hose Stations.Caused by Failure to Provide Deviation Documentation.Place Extinguishers in Fire Brigade Locker + (ML20236K428)