Text

_.

UNITED STATES

[f

>A Hog *jo NUCLEAR REGULATORY COMMISSION REGION 88 i

o I

g j

101 MARIETTA STREET, N.W.

t-ATLANTA, GEORGI A 30323 4

o 9,,,,,g June 26, 1986 MEMORANDUM FOR: Clemens J. Heltemes, Jr., Director, Of fice for Analysis and Evaluation of Operational Data FROM:

J. Nelson Grace, Regional Administrator

SUBJECT:

COMMENTS ON ABNORMAL OCCURRENCE REPORf TO CONGRESS FOR FIRST QUARTER CY 1986 i

Enclosed is a list of comments on the Abnormal Occurrence Report to Congress for the First Quarter CY 1986 as requested by your memorandum dated June 16, 1986.

1 lAt J. Nelson Grace

Enclosure:

Region II Comments l

l i

i l

l l

s CONTACT:

R. Aiello FTS:

242-4196 8070111 870804

~{ 870 PDR FOIA PDR 00RDONB7-377

1 m 26, W6 I^

ENCLOSURE l

REGION II COMMENT.S i

Appendix B, Number 85-14 (Management Deficiencies at Tennessee Valley Authority):

1.

Change the last two sentences-of the paragraph (The NRC staff, led by a senior...) to read as follows-The staff briefed the Commission on TVA status on February 7,1986 and-j March 11, 1986.

i i

2.

Following the paragraph (By letter dated March 10, 1986, TVA... by the staff), insert the following sentence l

TVA intends to revise the response submitted concerning Sequoyah, but a i

revised response has not been received. TVA has not responded to the Browns Ferry and Watts Bar concerns.

3.

Change the paragraph (There are five areas where.

.) to read as follows:

There are six areas where...

4.

Change the paragraph (As TVA has completed portions of.

. will be cenducted) to read as follows:

As TVA has completed.

. -(EQ) effort, the staff conducted... reviews at Sequoyah, including... will be conducted.

5.

Following the paragraph (Discrepancies identified by both in compliance with the EQ rule.), insert the following paragraph:

Cables and unqualified electrical equipment are currently being replaced or upgraded in ths Browns Ferry Unit 2 drywell (first Browns Ferry unit scheduled to be restarted).

6.

Following the paragraph (TVA and the staf f.

and Watts Bar.), insert the following paragraph:

Operational Readiness (Sequoyah)

Operational readiness inspections by Region II are continuing.

Some deficiencies have been identified which will require resolution prior to restart. These deficiencies are in the areas of: surveillance activities, maintenance, operating experience, pipe supports, and radiation protection.

p[gaarc' g

,'o UNITED STATES g

l

)7 p,

NUCLE.AR REGULATORY COMMISSION l

l r,,

j WASHINGTON, D. C. 20555 l

'%.....Y ffgin f t

l l

June 26, 1986 MEMORANDUM FOR: Clemens J. Heltemes, Jr., Director, Office for Analysis and Evaluation of Operational Data l

FROM:

J. Nelron Grace, Regional Administrator l

SUBJECT:

COMMENTS ON ABNORMAL OCCURRENCE REPORT TO CONGRESS FOR FIRST QUARTER CY 1986 i

l l

Enclosed is a list of comments on the Abnonnal Occurrence Report to Congress l

for the First Quarter CY 1986 as requested by your men:orandum dateo June 16, 1986.

l Original Signed by Roger D. Walker /for J. Nelson Grace l

Enclosure:

Region II Comments

[ j' h.

e,q (fhfgg I

CONTACT:

R. Aiello FTS:

242-4196

l l

MEMORANDUM FOR: Clemens J. Heltemes, Jr., Director, Office for Analysis and Evaluation of Operational Data l

FROM:

J. Nelson Grace, Regional Administrator l

l

SUBJECT:

COMMENTS ON ABNORMAL OCCURRENCE REPORT TO CONGRESS FOR FIRST l

QUARTER CY 1986 j

l 1

Enclosed is a list of comments on the Abnormal Occurrence Report to Congress for the First Quarter CY 1986 as requested by your memorandum dated June 16, 1986.

l J. Nelson Grace

Enclosure:

Region II Comments CONTACT:

R. Aiello FTS:

242-4196 RII RII RII RII RII RAiello Klandis SWeise LReyes RWalker 06/ /86 06/ /86 06/ /86 06/ /86 06/ /86

1 l

ENCLOSURE i

REGION II COMMENTS Appendix B, Number 85-14 (Management Deficiencies at Tennessee Valley Authority):

1.

Change the last two sentences of the paragraph (The NRC staff, led by a

]

senior...) to read as follows:

i The staff briefed the Commission on TVA status on February 7,1986 and March 11, 1986.

)

2.

Following the paragraph (By letter dated March 10, 1986, TVA... by the 1

staff), insert the following sentence:

l TVA intends to revise the response submitted concerning Sequoyah, but a revised response has not been received.

TVA has not responded to the Browns 1

Ferry and Watts Bar concerns.

3.

Change the paragraph (There are five areas where...) to read as follows:

There are six areas where...

2 4.

Change the paragraph (As TVA has completed portions of... will be conducted) to read as follows:

1 As TVA has completed... (EQ) effort, the staff conducted... reviews at Sequoyah, including... will be conducted, u

i 5.

Following the paragraph (Discrepancies identified by both.

in l

compliance with the EQ rule.), insert the following paragraph:

i i

Cables and unqualified electrical equipment are currently being replaced or l

upgraded in the Browns Ferry Unit 2 drywell (first Browns Ferry unit scheduled to be restarted).

i 6.

Following the paragraph (TVA and the staff... and Watts Bar.), insert the following paragraph:

j Operational Readiness (Sequoyah) 1 Operational readiness inspections by Region II are continuing.

Some deficiencies have been identified which will require resolution prior to restart.

These deficiencies are in the areas of:

surveillance activities, maintenance, operating experience, pipe supports, and radiation protection.

1

(

l i

l I

f I

I l

1

=-

d

. jo UNITED STATES v.

g

[

g NUCLEAR REGULATORY COMMISSION G

hj WASHINGTON, D. C. 20555 l

'+9.... 9 0

June 25, 1986 1

MEMORANDUM FOR: Clemens J. Heltemes, Jr., Director, Office for Analysis and Evaluation of Operational Data FROM:

J. Nelson Grace, Regional Administrator

SUBJECT:

COMMENTS ON ABNORMAL OCCURRENCE REPORT TO CONGRESS FOR FIRST i

j QUARTER CY 1986 l

l Enclosed is a list of comments on the Abnormal Occurrence Report to Congress for the First Quarter CY 1986 as requested by your memorandum dated June 16, 1986.

'll 1

Original Signed by Roger D. Walker /for J. Nelson Grace

Enclosure:

)

Region II Comments l

(

f, y I

fl g ( 'b. 9, C

[

b o'(d

)

l P

f', f

, 7' A

1 r

i b

i V

l i

l l

I CONTACT:

R. Aiello FTS:

242-4196 i

l i

i

l

\\ /

1 MEMORANDUM FOR: Clemens J. Heltemes, Jr., Director, Office for Analysis and Evaluation of Operational Data FROM:

J. Nelson Grace, Regional Administrator

SUBJECT:

COMMENTS ON ABNORMAL OCCURRENCE REFORT TO CONGRESS FOR FIRST QUARTER CY 1986 Enclosed is a list of comments on the Abnormal Occurrence Report to Congress g,,-

for the First Quarter CY 1986 as requested by your memorandum dated June 16, 1986.

l J. Nelson Grace

Enclosure:

Region II Comments I

l I

\\

\\

CONTACT:

R. Aiello FTS: 242-4196 l

7 l

RIT RII RII RII

/

,)g s

RAiello KLandis LReyes RWalker 06/ /86 06/ /86 06/ /86 06/s./86 e'

1 i

r

=..

ENCLOSURE REGION II COMMENTS Appendix B, Number 85-14 (Management Deficiencies at Tennessee Valley Authority):

1.

Following the paragraph (This Abnormal Occurrence was... it is updated as follows.), insert the following paragraph Enforcement conferences (EC) were held with TVA May 28, May 30, and June 19, 1986.

The May 28 EC concerned the continuing breakdown in management controls for Browns Ferry as demonstrated by multiple examples 1

of violations identified since August 1985 involving seismic criteria; 10 CFR 50, Appendix B, Criteria III, V, and XVI; and a 10 CFR 50.59 y'

70 evaluauon.

ine-May*B8 EC involved inadequate surveillance testing to demonstrate Technical Specification requirements.

The June 19 EC concerned intimidation and harassment of an employee who identified and reported safety concerns.

1 2.

Change the lest two sentences of the paragraph (The NP,C staff, led by a senior...) to read as follows:

The staff bricfed the Commission on TVA status on February 7,1986; March 11, 1986; and June 6, 1986.

3.

Following the paragraph (By letter dated March 10, 1986, TVA... by the staff), insert the following sentence:

The response submitted concerning Sequoyah has been withdrawn by TVA, and a revised response has not been received.

TVA has not responded to the Browns Ferry concerns.

4.

Change the paragraph (As TVA has completed portions of... will be conducted) to read as follows:

)

l l

As TVA has completed... (EQ) effort, the staff conducted... reviews at Sequoyah, including... will be conducted.

5.

Following the paragraph (Discrepancies identified by both.

in 1

compliance with the EQ rule.), insert the following paragraph:

Cables and unqualified electrical equipment are currently being replaced or l

upgraded in the Browns Ferry Unit 2 drywell (first Browns Ferry unit scheduled to be restarted).

i 3

6.

Following the paragraph (TVA and the staff... and Watts Bar.), insert the following paragraph:

7 Operational Readiness (Sequoyah)

Y' g

c,i g

Operational readiness inspections by Region II are continuing.

Some

'p deficiencies have been identified which will require resolution prior to restart.

These deficiencies are in the areas of: surveillance activities,

'/

l maintenance, operating experience, pipe supports, and radiation protection.

Enclosure 2

7.

Following the paragraph (Members of the staff were at the nondestructive examination van.), insert the following sentence:

An additional NRC walding inspection was conducted during the weeks ending June 6 and 20, 1986.

i i

s m___

'