Advises That Replaced Section of 2-inch Inservice Insp Class 2 Piping,Discussed in ,Consists of Second & Third Elbows Interior of Containment for Steam Generator 22 Bottom Blowdown Line
ML20236K361
Person / Time
Site: Calvert Cliffs 
Issue date: 10/31/1987
From: Larragoite L
BALTIMORE GAS & ELECTRIC CO.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
NUDOCS 8711090202
Download: ML20236K361 (1)


Text

__

1'

- BALTIMORE GAS AND ELECTRIC CHARLES CENTER. P.O. BOX 1475 BALTIMORE, MARYLAND 21203 NUCLEAR ENGINEERING SERVICES DEPARTMENT l

CALVERT CUFF 8 NUCLEAR POWER PLANT l

LUSBY, MARYLAND 20657 October 31, 1987 i

)

l U. S. Nuclear Regulatory Commission j

Washington, DC 20555.

' ATTENTION:

Document Control Desk

SUBJECT:

Calvert Cliffs Nuclear Power Plant Unit No. 2; Docket No. 50-318 j

Request for Permission to Use ASME Boiler and Fressure J

Vessel Code Case N-416

REFERENCE:

(a) Letter from Mr.

W.

J.

Lippold (BG&E) to NRC Document Control Desk, dated October 31, 1987,- same subject Gentlemen:

l The replaced section of two-inch ISI Class 2 piping, discussed in Reference. (a),

consists of the second and third elbows interior of the e,ontainment for the No. 22 steam generator' bottom blowdown line.

IWC-3000 required repair or replacement of the pipe. The repair and replacement will be done in accordance l

with IWA-4000 and IWA-7000. Code Case N-416 provides an acceptable alternative s

to the system hydrostatic test required by IWA-4400.

Should you have any further questions regarding this matter, we will be j

pleased to discuss them with you.

l l

Very truly yours, s

Louis S. Larragoite Engineer l

Licensing and Operational Safety j

i LSL/-11m cc:

D. A. ' Brune, Es. quire J. E. Silberg, Esquire R. A. Capra, NE.C S. A. McNeil, WRC W. T.' Russell, NRC

-9

.T. Foley/D. C. Trimble, NRC 9711090202 871031 PDR-ADOCK 05000319 1 g' P