Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- W3P87-2060, Forwards Changes to QA Program (FSAR Section 17.2) Re Significant Transition at Facility from Const to Operations Phase Which Included Major Reorganization of Nuclear Operations Dept.Fee Paid + (ML20235S735)
- ML20235S739 + (ML20235S739)
- ML20235S747 + (ML20235S747)
- PNO-I-87-065, on 870715,patient Received Palliative Treatment Dose Approx 50% Less than One Prescribed.Caused by Medical Physicist Error in Failing to Load Two Cs-137 Sources. Licensee Reviewing Options for Corrective Actions + (ML20235S753)
- ML20235S755 + (ML20235S755)
- ML20235S757 + (ML20235S757)
- 05000482/LER-1987-035, :on 870903,control Room Ventilation Isolation Signals Occurred.Caused by Malfunctions of Chlorine Monitors.Signal Reset & Monitor Placed in Bypass for Troubleshooting + (ML20235S758)
- ML20235S767 + (ML20235S767)
- ML20235S769 + (ML20235S769)
- ML20235S770 + (ML20235S770)
- 05000498/LER-1989-005, :on 890120,alarms for Turbine Generator High Vibration & Bearing 8 & 9 High Temp Received W/Fire Subsequently Reported at Bearing 9.Caused by Loss of Cooling Hydrogen Due to Loose Temp Sensor Connection + (ML20235S772)
- ML20235S773 + (ML20235S773)
- ML20235S778 + (ML20235S778)
- 05000368/LER-1988-019, :on 881111,during Disassembly of Svc Water Pump A,Failure of Some of Impeller Snap Rings Discovered. Caused by Corrosion of Impeller Carbon Steel Snap Rings Due to Exposure of Chlorinated Lake Water + (ML20235S783)
- ML20235S784 + (ML20235S784)
- IR 05000373/1987018 + (ML20235S786)
- ML20235S789 + (ML20235S789)
- ML20235S790 + (ML20235S790)
- ML20235S792 + (ML20235S792)
- ML20235S794 + (ML20235S794)
- ML20235S797 + (ML20235S797)
- ML20235S799 + (ML20235S799)
- ML20235S800 + (ML20235S800)
- IR 05000155/1989002 + (ML20235S804)
- IR 05000206/1988028 + (ML20235S809)
- ML20235S810 + (ML20235S810)
- HL-7514, Record of Telcon W/Ca Ayala,Ma Friedlander,Rl Perch,R Emch & C Moon on 870708 to Clarify Intent & Proper Interpretation of Encl marked-up Final Draft Tech Spec Table 3.3-3 + (ML20235S811)
- ML20235S812 + (ML20235S812)
- ML20235S818 + (ML20235S818)
- ML20235S824 + (ML20235S824)
- IR 05000412/1987045 + (ML20235S825)
- ML20235S827 + (ML20235S827)
- ML20235S834 + (ML20235S834)
- ML20235S837 + (ML20235S837)
- ML20235S838 + (ML20235S838)
- IR 05000454/1987024 + (ML20235S840)
- ML20235S841 + (ML20235S841)
- ML20235S844 + (ML20235S844)
- ML20235S845 + (ML20235S845)
- ML20235S852 + (ML20235S852)
- ML20235S853 + (ML20235S853)
- ML20235S854 + (ML20235S854)
- ML20235S857 + (ML20235S857)
- ML20235S858 + (ML20235S858)
- ML20235S861 + (ML20235S861)
- ML20235S862 + (ML20235S862)
- ML20235S863 + (ML20235S863)
- 05000254/LER-1987-016-06, :on 870912,determined That Measured Combined Leakage Rate from All Penetrations & Valves,Excluding MSIV, Exceeded Tech Spec Limits.Cause Not Yet Determined. Investigation Underway + (ML20235S868)
- ML20235S870 + (ML20235S870)
- ML20235S873 + (ML20235S873)
- ML20235S883 + (ML20235S883)