Forwards Ga Co Info Memo on CRD Switches.Preventive Maint Should Be Performed to Avoid Sluggish or Sticking Behavior of Switches.Problem Considered Generic & Does Not Affect Safety Circuitry of Console
ML20235S841
Person / Time
Site: Reed College
Issue date: 02/27/1989
From: Michaels T
Office of Nuclear Reactor Regulation
To: Berlinger C
Office of Nuclear Reactor Regulation
Shared Package
ML20235S842 List:
References
NUDOCS 8903080040
Download: ML20235S841 (2)


Text

_

p.{'

February 27, 1989 MEMORANDUM FOR: Carl H. Berlinger, Chief Generic Communications Branch Division of Operational Events Assessment, NRR FROM:

Theodore S. Michaels, Project Manager Standardization and Non-Power Reactor Project Directorate Division of Reactor Projects - III, IV, V and Special Projects, NRR

SUBJECT:

GENERAL ATOMICS INFORMATION MEMORANDUM ON CONTROL R00 DRIVE SWITCHES The ' enclosed memorandum to "All TRIGA Research Reactor Facilities" from General Atomics, manufacturer of the TRIGA research reactors, discusses the preventive maintenance that should be performed to avoid sluggish or sticking behavior of the control rod drive switches. The information memorandum was

- developed because one of the "up" switches at Reed College stuck, and the control rod kept withdrawing, as described in the memorandum.

The problem has apparently occurred at other TRIGA reactors and therefore is generic.

It, however, does not affect the safety circuitry of the console since power and fuel temperature scrams are unaffected by the switches.

Also enclosed, for your information, is a description of the event at Reed College.

/s/

Theodore S. Michaels, Project Manager Standardization and Non-Power Reactor Project Directorate Division of Reactor Projects - III, IV, V and Special Projects, NRR

Enclosures:

As stated CONTACT:

T. Michaels NRR/PDSNP 492-1102

, DISTRIBUTION:

iTocket File,.

Sb-288 EJordan NRC & Local PDRs BGrimes PDSNP R/F OGC EHylton ACRS(10)

TMichaels

)

(MEM0 FOR CARL BERLINGER) n M f0N PM:PDSNPf D:PD TMichaelf:g CMiller cw 02/2y89 02/u/89 I

g=3 E8s! SEnygs

m=----

UNITED STATES 4

NUCLEAR REGULATORY. COMMISSION f, [

y, 8

casHINGTcN, D. C. 20555

_5 February 27, 1989 v

MEMORANDUM FOR: Carl.H. Berlinger, Chief -

Generic Communications Branch Division of Operational Events Assessment, NRR FROM:-

Theodore S. Michaels, Project Manager Standardization and Non-Power Reactor Project Directorate' Division of Reactor Projects - III, IV, Y and Special Projects, NRR

SUBJECT:

GENERAL ATOMICS INFORMATION MEMORANDUM ON CONTROL R0D DR!IVE SWITCHES The enclosed memorandum to "All TRIGA Research Reactor Facilities" from General Atomics, manufacturer of the TRIGA research reactors, discusses the preventive maintenance that should be performed to avoid sluggish,or sticking behavior of-the control rod drive switches. The information memorandum was developed because one of the "up" switches at Reed College stuck. and the contro1~ rod kept withdrawing, as described in the memorandum.

The problem has apparently occurred at other TRIGA reactors and therefore is It, however, does not affect the safety circuitry of the console gener_ic.

since power and fuel temperature. scrams are unaffected by the switches.

Also enclosed, for your infonnation, is a description of the event at Reed' College.

Theodore S. Michaels, Project Manager-Standardization and Non-Power Reactor Project Directorate Division of Reactor Projects - III, IV, Y and Special Projects, NRR

Enclosures:

As stated CONTACT: