Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000244/LER-1986-004, :on 860729,reactor Tripped Manually When Large Steam Leak Discovered in Turbine Bldg.Caused by Leak in Pipe Elbow on Moisture Separator Reheater Drain Line 2A.Elbow Replaced & Tested Satisfactorily + (ML20212Q129)
- ML20212Q130 + (ML20212Q130)
- 05000327/LER-1987-018, :on 870317,during Cold Shutdown,Surveillance Instruction SI-166.16 Re Component Cooling Sys Check Valve Test Found Inadequate.Caused by Personnel Error.Instruction Changed to Acceptable Test Method + (ML20212Q135)
- ML20212Q137 + (ML20212Q137)
- ML20212Q142 + (ML20212Q142)
- IR 05000346/1987007 + (ML20212Q144)
- ML20212Q145 + (ML20212Q145)
- ML20212Q146 + (ML20212Q146)
- IR 05000443/1986027 + (ML20212Q147)
- ML20212Q148 + (ML20212Q148)
- ML20212Q151 + (ML20212Q151)
- ML20212Q156 + (ML20212Q156)
- ML20212Q160 + (ML20212Q160)
- ML20212Q161 + (ML20212Q161)
- 05000423/LER-1986-044, :on 860731,liquid Discharge Valve Bypassed W/O Required Double Valve Lineup Verification.Caused by Operator Error.Personnel Counseled in Requirements for Alternate Effluent Discharge Procedures + (ML20212Q162)
- ML20212Q168 + (ML20212Q168)
- ML20212Q169 + (ML20212Q169)
- ML20212Q171 + (ML20212Q171)
- ML20212Q178 + (ML20212Q178)
- ML20212Q182 + (ML20212Q182)
- BECO-86-126, Requests Schedular Exemption from 10CFR50,App J Re Type a Test.Exemption Requested to Preclude Necessity of Performing Two Type a Tests During Refueling Outage 7 by Allowing Performance of Only One Test Following Refueling + (ML20212Q183)
- ML20212Q184 + (ML20212Q184)
- ML20212Q187 + (ML20212Q187)
- ML20212Q188 + (ML20212Q188)
- ML20212Q189 + (ML20212Q189)
- ML20212Q192 + (ML20212Q192)
- ML20212Q196 + (ML20212Q196)
- ML20212Q200 + (ML20212Q200)
- ML20212Q205 + (ML20212Q205)
- ML20212Q209 + (ML20212Q209)
- ML20212Q210 + (ML20212Q210)
- ML20212Q212 + (ML20212Q212)
- ML20212Q215 + (ML20212Q215)
- ML20212Q218 + (ML20212Q218)
- ML20212Q219 + (ML20212Q219)
- ML20212Q221 + (ML20212Q221)
- IR 05000213/1986023 + (ML20212Q225)
- ML20212Q230 + (ML20212Q230)
- ML20212Q233 + (ML20212Q233)
- ML20212Q238 + (ML20212Q238)
- IR 05000327/1986039 + (ML20212Q242)
- ML20212Q247 + (ML20212Q247)
- ML20212Q253 + (ML20212Q253)
- ML20212Q273 + (ML20212Q273)
- ML20212Q277 + (ML20212Q277)
- ML20212Q279 + (ML20212Q279)
- BECO-86-123, Forwards Revised Tech Spec Page 204A,incorporating Modified Footnote Ref in 811002 Application for Amend 49 to License DPR-35 Re Spiral Unloading of Fuel Cells to Facilitate Insp + (ML20212Q281)
- ML20212Q292 + (ML20212Q292)
- 05000331/LER-1986-018, :on 860802 & 03,RCIC Sys Declared Inoperable. Caused by Planned Maint on Valve MO-2517,involving Rewiring to Meet Environ Qualification Requirements + (ML20212Q293)
- B12221, Forwards Addl Info Re Action Items Resulting from App R Insp on 860616-20 for Listed Topics & Brief Summary & Status Update of All Other Open Audit Issues.Response to Violations & Deviation Will Be Provided by 860903 + (ML20212Q295)
- ML20212Q297 + (ML20212Q297)