ML20212Q279
| ML20212Q279 | |
| Person / Time | |
|---|---|
| Site: | LaSalle |
| Issue date: | 01/21/1987 |
| From: | Allen C COMMONWEALTH EDISON CO. |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| 2628K, NUDOCS 8702020205 | |
| Download: ML20212Q279 (1) | |
Text
/m
/-
\\ Commonwealth Edison I
! One Fir,1 National Plaza Chicago, Illinois
\\
l Address Reply to: Post Offica Box 767
\\_/ Chicago, Illinois 60690 0767 January 21, 1987 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C.
20555
Subject:
LaSalle County Station Unit 2 SOR Differential Pressure Switches Level Drop Data NRC Docket No. 50-374
Dear Sir:
Indicated below is the data from the level drop test performed during Unit 2 shutdown for refueling. The operating pressure (950 psig) level drop test was performed January 3, 1987 and the atmosphere pressure (0 psig) level drop test was done on January 5, 1987. The data shown has been corrected to account for drift in the Rosemont transmitters used for reference at each rack.
TRIP POINT (Inches Rx Water Level Indicated)
Trip point, "RWL" INSTRUMENT 950 psig 0 psig LS-2B21-N024A 18.1 18.5 LS-2B21-N024B 17.5 20.5 LS-2B21-N024C 17.5 20.7 LS-2B21-N024D 15.7 19.9 LS-2B21-N038A 11.2 18.4 LS-2B21-NO38B 13.6 19.5 If you have any additional questions regarding this matter, please contact this office.
V y truly yours, I
N$
V raco.
C. M. Allen Nuclear Licensing Administrator Do lm c:s OO 00 N4 cc:
Dr. A. Bournia - NRR O
Regional Administrator - RIII og NRC Resident Inspector - LSCS Ol 2628K l