Submits Data from Level Drop Test Performed During Unit 2 Shutdown for Refueling.Operating Pressure Test & Atmosphere Pressure Level Drop Test Performed on 870103 & 05, Respectively.Data Corrected for Drift of Transmitters
ML20212Q279
Person / Time
Site: LaSalle 
Issue date: 01/21/1987
From: Allen C
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
2628K, NUDOCS 8702020205
Download: ML20212Q279 (1)


Text

/m

/-

\\ Commonwealth Edison I

! One Fir,1 National Plaza Chicago, Illinois

\\

l Address Reply to: Post Offica Box 767

\\_/ Chicago, Illinois 60690 0767 January 21, 1987 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C.

20555

Subject:

LaSalle County Station Unit 2 SOR Differential Pressure Switches Level Drop Data NRC Docket No. 50-374

Dear Sir:

Indicated below is the data from the level drop test performed during Unit 2 shutdown for refueling. The operating pressure (950 psig) level drop test was performed January 3, 1987 and the atmosphere pressure (0 psig) level drop test was done on January 5, 1987. The data shown has been corrected to account for drift in the Rosemont transmitters used for reference at each rack.

TRIP POINT (Inches Rx Water Level Indicated)

Trip point, "RWL" INSTRUMENT 950 psig 0 psig LS-2B21-N024A 18.1 18.5 LS-2B21-N024B 17.5 20.5 LS-2B21-N024C 17.5 20.7 LS-2B21-N024D 15.7 19.9 LS-2B21-N038A 11.2 18.4 LS-2B21-NO38B 13.6 19.5 If you have any additional questions regarding this matter, please contact this office.

V y truly yours, I

N$

V raco.