- ML20211L930 + (ML20211L930)
- IR 05000237/1987003 + (ML20211L932)
- ML20211L933 + (ML20211L933)
- ML20211L935 + (ML20211L935)
- ML20211L936 + (ML20211L936)
- ML20211L937 + (ML20211L937)
- ML20211L938 + (ML20211L938)
- ML20211L940 + (ML20211L940)
- IR 05000441/1987001 + (ML20211L941)
- ML20211L943 + (ML20211L943)
- ML20211L945 + (ML20211L945)
- 05000249/LER-1986-019-06, :on 861113,scram Occurred Due to Two Simultaneous,Unrelated half-scrams.First half-scram Caused by Personnel Error.Second half-scram Caused by Dirty Connection in Circuit.Connection Cleaned + (ML20211L946)
- ML20211L948 + (ML20211L948)
- 05000328/LER-1986-007-04, :on 861111,error Discovered in Surveillance Instruction (SI) 246 Which Could Lead to Tech Spec Violation.Caused by Procedural error.SI-246 Will Be Revised & Flow Transmitters Will Be Recalibr + (ML20211L950)
- ML20211L952 + (ML20211L952)
- ML20211L953 + (ML20211L953)
- ML20211L955 + (ML20211L955)
- ML20211L959 + (ML20211L959)
- ML20211L962 + (ML20211L962)
- ML20211L964 + (ML20211L964)
- ML20211L967 + (ML20211L967)
- ML20211L968 + (ML20211L968)
- ML20211L971 + (ML20211L971)
- ML20211L972 + (ML20211L972)
- ML20211L973 + (ML20211L973)
- ML20211L975 + (ML20211L975)
- ML20211L977 + (ML20211L977)
- ML20211L979 + (ML20211L979)
- ML20211L982 + (ML20211L982)
- ML20211L983 + (ML20211L983)
- 05000409/LER-1986-034, :on 861112,containment Ventilation Valves Closed Automatically When Indication on Containment Bldg Immediate Particulate Monitor Spiked High.Caused by Manipulation of Range Switch.Contacts Cleaned + (ML20211L984)
- ML20211L987 + (ML20211L987)
- ML20211L988 + (ML20211L988)
- ML20211L996 + (ML20211L996)
- ML20211L997 + (ML20211L997)
- PNO-I-87-011, on 870214,reactor Scram Occurred from 100% Power Due to Turbine Trip Which Resulted from Reactor High Water Level Condition.Caused by Technician Disturbing Lead in Level Control Sys.Plant Taken to Cold Shutdown + (ML20211M000)
- ML20211M003 + (ML20211M003)
- ML20211M004 + (ML20211M004)
- ML20211M005 + (ML20211M005)
- ML20211M006 + (ML20211M006)
- ML20211M008 + (ML20211M008)
- ML20211M010 + (ML20211M010)
- TXX-6116, Summary of Analysis Used to Evaluate Habitability of Comanche Peak Steam Electric Station Control Room During Postulated Chlorine Release + (ML20211M013)
- L-99-132, Forwards fitness-for-duty Program Six Month Rept for 990101-990630 for Bvps,Units 1 & 2 + (ML20211M014)
- ML20211M015 + (ML20211M015)
- ML20211M017 + (ML20211M017)
- ML20211M018 + (ML20211M018)
- 05000298/LER-1986-032, :on 861110,one Valve Determined to Actuate at Pressure of 4 Psi Lower than Allowable.Caused by Setpoint Drift.Corrective Action Included Normal Refurbishment Activities & Certification Testing + (ML20211M020)
- ML20211M021 + (ML20211M021)
- 05000259/LER-1986-031-01, :on 861105,reactor Protection Sys Channel 1A Deenergized When Circuit Protector Tripped Motor Generator Set.Caused by Dirty Voltage Adjustment Potentiometer. Potentiometer Cleaned + (ML20211M024)