Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20210D798 + (ML20210D798)
- ML20210D799 + (ML20210D799)
- ML20210D801 + (ML20210D801)
- ML20210D802 + (ML20210D802)
- ML20210D806 + (ML20210D806)
- ML20210D809 + (ML20210D809)
- ML20210D810 + (ML20210D810)
- ML20210D811 + (ML20210D811)
- PNO-I-86-023, on 860321,while Replacing CRD Housing Support Underneath Reactor Vessel,Platform Gave Way Injuring & Contaminating Work Person.Employee Decontaminated Onsite Prior to Transfer to Hosp + (ML20210D812)
- ML20210D814 + (ML20210D814)
- IR 05000454/1986005 + (ML20210D816)
- ML20210D818 + (ML20210D818)
- 05000354/LER-1987-002, :on 870108,control Room Ventilation Sys (CRV) Isolated & Control Room Emergency Filtration Actuated. Caused by Personnel Error.Technician Counseled to Refrain from Accessing Equipment W/O Authorization + (ML20210D820)
- ML20210D823 + (ML20210D823)
- IR 05000354/1986007 + (ML20210D824)
- ML20210D825 + (ML20210D825)
- ML20210D828 + (ML20210D828)
- JAFP-92-0458, Monthly Operating Rept for May 1992 for Ja FitzPatrick Nuclear Power Plant + (ML20210D831)
- ML20210D832 + (ML20210D832)
- ML20210D833 + (ML20210D833)
- ML20210D835 + (ML20210D835)
- ML20210D838 + (ML20210D838)
- ML20210D840 + (ML20210D840)
- ML20210D841 + (ML20210D841)
- ML20210D842 + (ML20210D842)
- ML20210D846 + (ML20210D846)
- ML20210D847 + (ML20210D847)
- ML20210D850 + (ML20210D850)
- ML20210D851 + (ML20210D851)
- BECO-92-062, Monthly Operating Rept for May 1992 for Pilgrim Nuclear Power Station + (ML20210D852)
- IR 05000461/1986016 + (ML20210D854)
- ML20210D858 + (ML20210D858)
- ML20210D860 + (ML20210D860)
- ML20210D861 + (ML20210D861)
- ML20210D863 + (ML20210D863)
- ML20210D868 + (ML20210D868)
- ML20210D870 + (ML20210D870)
- ML20210D872 + (ML20210D872)
- IR 05000373/1985035 + (ML20210D874)
- PNO-IV-87-006, on 870122,instrument Technician Found to Be Contaminated When Exiting Work Area Control Point. Investigation Revealed Technician Actually Contaminated on 870121.No Other Offsite Contamination Identified + (ML20210D876)
- AECM-86-0275, Application to Amend License NPF-29,revising Tech Specs to Add Inboard Isolation Valve & Two Test Connection Valves to Penetration 71B,to Meet Intent of Reg Guide 1.11.Fee Paid + (ML20210D878)
- ML20210D880 + (ML20210D880)
- ML20210D881 + (ML20210D881)
- B12011, Forwards Rev 1 to Physical Security Plan.Rev Withheld (Ref 10CFR73.21 & 2.790) + (ML20210D884)
- ML20210D885 + (ML20210D885)
- ML20210D887 + (ML20210D887)
- ML20210D889 + (ML20210D889)
- ML20210D890 + (ML20210D890)
- ML20210D893 + (ML20210D893)
- ML20210D895 + (ML20210D895)
- ML20210D896 + (ML20210D896)