Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20198H358 + (ML20198H358)
- ML20198H359 + (ML20198H359)
- ML20198H362 + (ML20198H362)
- ML20198H365 + (ML20198H365)
- ML20198H366 + (ML20198H366)
- ML20198H367 + (ML20198H367)
- ML20198H368 + (ML20198H368)
- ML20198H369 + (ML20198H369)
- ML20198H371 + (ML20198H371)
- ML20198H372 + (ML20198H372)
- ML20198H373 + (ML20198H373)
- ML20198H374 + (ML20198H374)
- ML20198H376 + (ML20198H376)
- ML20198H377 + (ML20198H377)
- ML20198H380 + (ML20198H380)
- ML20198H381 + (ML20198H381)
- ML20198H382 + (ML20198H382)
- PNO-III-97-070A, on 970820,buried Source of Radiation Found on School Campus Update Made.Us Army Corps of Engineers Requestsed State of Oh to Characterize Contamination & to Remediate Site.Soil Samples Taken & Analyzed + (ML20198H383)
- ML20198H386 + (ML20198H386)
- ML20198H388 + (ML20198H388)
- ML20198H389 + (ML20198H389)
- ML20198H391 + (ML20198H391)
- IA-85-534, Advises That Encl Draft Papers Rev to NRC Safeguards Design Basis Threat & Comparison of Agency Response to Truck Bomb Threat in Us Contain Confidential Natl Security Info.W/O Encl + (ML20198H393)
- ML20198H393 + (ML20198H393)
- ML20198H394 + (ML20198H394)
- ML20198H395 + (ML20198H395)
- ML20198H396 + (ML20198H396)
- ML20198H397 + (ML20198H397)
- ML20198H400 + (ML20198H400)
- ML20198H401 + (ML20198H401)
- ML20198H403 + (ML20198H403)
- ML20198H404 + (ML20198H404)
- BSEP-85-2207, Special Rept 2-8R-85-08:on 851129,determined That Fire Door 303,located at 50-ft Reactor Bldg Air Lock,Inoperable.Caused by Broken Latching Mechanism.Mechanism Throughly Cleaned & Lubricated.Part 21 Related + (ML20198H405)
- ML20198H406 + (ML20198H406)
- ML20198H408 + (ML20198H408)
- ML20198H409 + (ML20198H409)
- U-602821, Informs of Change in Date That Ilpr Intends to Implement Formal Industry Position on Severe Accident Mgt Approved by Nuclear Energy Institutes Nuclear Strategic Issues Advisory Committee on 970804 + (ML20198H410)
- ML20198H411 + (ML20198H411)
- ML20198H412 + (ML20198H412)
- ML20198H414 + (ML20198H414)
- ML20198H416 + (ML20198H416)
- ML20198H417 + (ML20198H417)
- ML20198H418 + (ML20198H418)
- ML20198H419 + (ML20198H419)
- 05000296/LER-1986-005-03, :on 860215,containment Isolation Occurred. Caused by Relay Failure in Refuel Zone Exhaust Radiation Monitor.Relay Replaced & Isolation Reset + (ML20198H420)
- 3F0198-07, Special Rept 97-09:provides Details of Conditions Found Not Meeting Acceptance Criteria During Ongoing Twentieth Year Tendon Surveillance of Containment Post Tensioning Sys. Commitments Encl + (ML20198H421)
- ML20198H422 + (ML20198H422)
- ML20198H424 + (ML20198H424)
- ML20198H425 + (ML20198H425)
- 3F0997-20, Provides Response to Violations Noted in Insp Rept 50-302/97-10.Corrective Actions:All Ten Security Zones Immediately Compensated by Posting Security Force Personnel to Act as Assessors in Event Alarm Received + (ML20198H426)
- ML20198H427 + (ML20198H427)