ML20198H406

From kanterella
Jump to navigation Jump to search
Non-proprietary HI-87113, Evaluation of Fluid Flow for In- Phase & Out-of-Phase Rack Motions
ML20198H406
Person / Time
Site: Waterford 
Issue date: 04/30/1987
From: Paul B
HOLTEC INTERNATIONAL
To:
Shared Package
ML20198H363 List:
References
HI-87113-(NP), NUDOCS 9812290335
Download: ML20198H406 (5)


Text

. _.

l l

l l

l EVALUATION OF FLUID FLOW FOR IN-PHASE AND OUT-OF-PHASE RACK MOTIONS by g

B. Paul Director, Dynamic Systems and Structures Holtec International Holtec Report No. HI-87113 Holtec Project 61200 April, 1987 I

l l

9812290335 981223 %

PDR ADOCK 05000382' PMg P

i

p;._ _ _ _

1 1

HOLTEC INTERNATIONAL REVIEW AND CERTIFICATION LOG 1

DOCUMENT NAME:

Evaluation of Fluid Flow for In-Phase i

and Out-of-Phase Rack Motions HOLTEC DOCUMENT I.D. NO.

HI-87113 i

HOLTEC PROJECT NO.

61200 j

CUSTOMER / CLIENT:

Pacific Gas and Electric i

~

REVISION BLOCK 1

ISSUE NO.

AUTHOR REVIEWER QA MANAGER APPROVED *

& DATE

& DATE

& DATE BY & DATE i

Aljtxf J'A.En p{ Q%%

4. W =~=

2ikQAt-ORIGINAL ISSUE S rgWh gge V g 'y W 4/ 9/ A y g

REVISION 1

{

REVISION 2 NOTE:

Signatures and printed names are required in j

the review block.

  • Must be Section Director or the President.

4 4

j This document conforms to the requirements of the design specification and the applicable sections of the governing codes.

i i

This document bears the ink stamp of the professional engineer who is certifying this document.

hb9I Professional Engineer SEAL

'.q. M,: 2'r 'y n. w.a q,

e ci sm, u ggl.

r a...,s

(! KR!S!;:A Pl.L SINGH L

,.,,,.j.

S' MN-(

'kf g.p/

i u

. _. _ _ _... ~

1_

TABLE OF CONTENTS f

a 1.

PROBLEM STATEMENT 2.

FLOM PATTERNS 2.1 Model I 2.2 Model II i

3.

MODEL I KINETIC ENERGY 7

3.1 General i

[

3.2 In-Phase Motion 2

3.3 Out-of-Phase Motion

.i

.i 4.

MODEL II KINETIC ENERGY 4.1 General s

I 4.2 In-Phase Motion j

4.3 Out-of-Phase Motion j h 5.

EQUIVALENT CHANNEL MIDTH 5.1 In-Phase Motion i

5.2 Out-of-Phase Motion 6.

CONCLU3 IONS REFERENCES 4

k 1

i

-e

l/p'1 1.

PROBLEM STATEMENT In Reference 1, a method of analysis was given for finding the flow patterns of an inviscid fluid that fills the narrow channels between close-packed rectangular cells which are undergoing translational planar motions. Some examples were given for the kinetic energy of the fluid ~

when one or more cells were given a specified velocity.

For example, REMAINDER OF DOCUMENT IS PROPRIETARY AND.lS EXCLUDED FROM THIS NON-PROPRIETARY VERSION d'

1 4

g..

.]

/

i u

+

i 1

1 l'

c.

l'

-i

[-

]

L i

l.

i t'.

I p.

i

'i ENCLOSURE 6 o

. (Non-Proprietary Version of Attachment 4 to W3F1-98-0016, dated 1/29/98) l-l-

l I

I l

l.

l' I

I.

I i

i

,, 4

- -...