- ML20129H351 + (ML20129H351)
- ML20129H353 + (ML20129H353)
- ML20129H354 + (ML20129H354)
- ML20129H355 + (ML20129H355)
- ML20129H356 + (ML20129H356)
- ML20129H359 + (ML20129H359)
- 05000293/LER-1996-009, :on 960925,false High Reactor Vessel Pressure Signal Occurred.Caused by Deficiency in Procedure.Revised Procedure Used for Backfilling Applicable Reactor Vessel Pressure Transmitters + (ML20129H360)
- ML20129H363 + (ML20129H363)
- ML20129H364 + (ML20129H364)
- ML20129H365 + (ML20129H365)
- 05000456/LER-1996-011-05, :on 960924,identified Mgt Deficiencies Leading to Not Testing Installation of roll-up Fire Door Mod in Timely Manner,Resulting in Unanalyzed Condition.Doors Closed & Secured + (ML20129H367)
- ML20129H368 + (ML20129H368)
- ML20129H371 + (ML20129H371)
- ML20129H372 + (ML20129H372)
- PLA-4524, Forwards Change Kk to Station Physical Security Plan for Review.Encl Withheld + (ML20129H374)
- PNO-III-85-045, on 850602,reactor Trip & Main Feedwater Pump Trip Occurred.Caused by High Turbine Vibration.Cause of Main Feedwater Pump Trip Under Investigation.Plant in Hot Standby Mode + (ML20129H375)
- ML20129H376 + (ML20129H376)
- ML20129H377 + (ML20129H377)
- ML20129H378 + (ML20129H378)
- ML20129H379 + (ML20129H379)
- ML20129H380 + (ML20129H380)
- ML20129H382 + (ML20129H382)
- ML20129H383 + (ML20129H383)
- 05000275/LER-1985-014, :on 850518,reactor Tripped Followed by Safety Injection.Caused by Failure of Slave 2.S Kva Regulating Transformer.Transformer Replaced & Inverter Returned to Svc + (ML20129H384)
- ML20129H385 + (ML20129H385)
- ML20129H386 + (ML20129H386)
- ML20129H388 + (ML20129H388)
- ML20129H390 + (ML20129H390)
- IR 05000454/1985002 + (ML20129H391)
- ML20129H392 + (ML20129H392)
- 05000482/LER-1985-043, :on 850609,feedwater Isolation Signal,Main Turbine Trip & Steam Generator Feed Pump Turbine Trip Signals Occurred Due to hi-hi Water Level in Steam Generator A.Caused by Leak Through Main Control Valves + (ML20129H393)
- ML20129H394 + (ML20129H394)
- IR 05000289/1985016 + (ML20129H397)
- ML20129H398 + (ML20129H398)
- 05000261/LER-1985-014-01, :on 850610,control Operator on Duty Left Shift Complement W/One Less Control Operator than Required by Tech Spec 6.2.3.a for Approx 15 Minutes Prior to Relief Control Operator Arrival + (ML20129H399)
- ST-HL-AE-5504, Submits List of Changes,Rev 6A & Temporary Addendums 4 & 5 Re Physical Security Plan.Encls Withheld + (ML20129H401)
- ML20129H403 + (ML20129H403)
- 05000369/LER-1985-020-01, :on 850607,diesel Generator 1B Experienced Two Invalid Automatic Starts.Caused by Power Distribution Sys Disturbances Due to Severe Weather.Start Sys Will Be Modified + (ML20129H405)
- ML20129H406 + (ML20129H406)
- ML20129H408 + (ML20129H408)
- PNO-III-85-044, on 850531,unit Manually Scrammed Due to Decreasing Vacuum in Condenser.Caused by Rupture of Flexible Expansion Joint on Discharge Side of Circulation Pump 1B Flooding Crib House & Causing Loss of All Svc Water + (ML20129H410)
- IR 05000277/1996010 + (ML20129H411)
- ML20129H413 + (ML20129H413)
- ML20129H414 + (ML20129H414)
- ML20129H415 + (ML20129H415)
- ML20129H417 + (ML20129H417)
- ML20129H418 + (ML20129H418)
- ML20129H421 + (ML20129H421)
- ML20129H423 + (ML20129H423)
- ML20129H425 + (ML20129H425)
- ML20129H427 + (ML20129H427)