- 05000338/LER-1984-018-01, :on 841012,turbine & Reactor Trip Occurred Due to Loss of Electro Hydraulic Control Sys Control Power. Caused by Technician Unfamiliarity W/Equipment.Technician Counseled + (ML20099B637)
- ML20099B644 + (ML20099B644)
- 05000368/LER-1979-066-03, /03X-1:on 790809,following Draining of Reactor Drain Tank,Outside Containment Isolation Valve 2CV-2201-2 Would Not Close.Caused by Foreign Matl Damaging Seats & Balls.Valve Disassembled,Cleaned & Reassembled + (ML20099B646)
- 05000361/LER-1985-013, :on 850130,control Room Isolation Sys Train B Spuriously Actuated by Instrument Failure on Control Room Radiation Monitor.Caused by Background Radiation Levels Dropping Below Instrument Failure Setpoint + (ML20099B648)
- 05000328/LER-1984-014-01, :on 840830,lo-lo Steam Generator Reactor Trip Occurred.Caused by Main Feedwater Isolation Valve Failing to Close Due to Stuck Contact & Main Feedwater Pump B Reset Due to Incorrect Solenoid Valve Setting + (ML20099B651)
- ML20099B652 + (ML20099B652)
- ML20099B655 + (ML20099B655)
- BECO-92-093, Requests Changes to NPDES Permit MA0003557,changing Listed Part I,Paragraphs A.1.m & A.1.n as indicated.Marked-up Page 5 of NPDES Permit Encl + (ML20099B656)
- 05000219/LER-1985-003, :on 850129,design Deficiency Discovered in Core Spray Sys Booster Pump Failure Logic.Caused by Deficiency in Original Plant Design.Mods to Replace Pressure Switches on Booster Pump Discharge Implemented + (ML20099B657)
- ML20099B686 + (ML20099B686)
- ML20099B693 + (ML20099B693)
- TXX-4423, Deficiency Rept SDAR-167 Re Cracked & Broken ERF Computer Termination Points.Initially Reported on 850201.Evaluation Continuing.Completion Anticipated by 850326 + (ML20099B718)
- ML20099B744 + (ML20099B744)
- ML20099B755 + (ML20099B755)
- ML20099B761 + (ML20099B761)
- ML20099B767 + (ML20099B767)
- ML20099B783 + (ML20099B783)
- ML20099B784 + (ML20099B784)
- B11359, Forwards Response to SER Confirmatory Item 16 Re Control Rod Drive Structural Matl + (ML20099B785)
- ML20099B787 + (ML20099B787)
- ML20099B790 + (ML20099B790)
- ML20099B792 + (ML20099B792)
- ST-HL-AE-4156, Forwards Response to NRC Bulletin 92-001 Re Thermo-Lag 330 Fire Barrier matl.Thermo-Lag 330 Fire Barrier Sys Used to Protect Safe Shutdown Circuits at Both Facilities.Hourly Fire Watches Established for Each Affected Fire Area + (ML20099B794)
- ML20099B795 + (ML20099B795)
- ML20099B802 + (ML20099B802)
- ML20099B803 + (ML20099B803)
- B11361, Informs That Error Identified in Attachment II to 841009 Discussion of 840510 Review Meeting Re Fire Related Core Melt Frequency Number.Error Corrected in Encl Revised Attachment II + (ML20099B804)
- ML20099B811 + (ML20099B811)
- ML20099B823 + (ML20099B823)
- ML20099B825 + (ML20099B825)
- ML20099B830 + (ML20099B830)
- 05000250/LER-1984-026, :on 841009,turbine Runback to 70% Reactor Power Occurred.Possibly Caused by Inadvertent Transfer of Power for Panel 3P07 from Normal Inverter 3A Spare Inverter As. Personnel Trained + (ML20099B836)
- ML20099B839 + (ML20099B839)
- RBG-19-413, Forwards Revised FSAR Section 8.3.1.4.2 Re Class 1E Electrical Equipment Arrangement.Reasons for Rev Discussed. Requests Concurrence by 841121 + (ML20099B841)
- ML20099B850 + (ML20099B850)
- 05000362/LER-1985-001-02, :on 850127,RCS Water Inventory Balance Indicated 2.97 Gpm Leakage Rate,Exceeding 1.0 Gpm Limit.On 850128,containment Purge Isolation Sys Train a Actuated from Airborne Iodine Resulting from Leak + (ML20099B853)
- ML20099B856 + (ML20099B856)
- ML20099B857 + (ML20099B857)
- ML20099B859 + (ML20099B859)
- ML20099B863 + (ML20099B863)
- ML20099B869 + (ML20099B869)
- ML20099B877 + (ML20099B877)
- ML20099B879 + (ML20099B879)
- ML20099B881 + (ML20099B881)
- ML20099B884 + (ML20099B884)
- ML20099B886 + (ML20099B886)
- ML20099B890 + (ML20099B890)
- 05000368/LER-1980-045-04, /04X-3:on 800702,0823 & 1102,condenser off-gas Radiation Monitor 2RE-0645 Found Inoperable.Caused by Erratic Radiation Element Signal.Plastic Coated Detector Installed & Moisture Resistant Epoxy Used + (ML20099B893)
- BSEP-84-2061, RO 1-SR-84-3:on 840827,Fire Doors 111 & 201 Limiting Conditions of Operation Initiated.Caused by Door Latch Closing Mechanism Preventing Automatic Closure.Doors Repaired & Returned to Svc While Fire Watch Maintained + (ML20099B894)
- ML20099B898 + (ML20099B898)
- ML20099B899 + (ML20099B899)