- 05000366/LER-1984-012, :on 840809,trip Signal to Reactor Water Cleanup Isolation Valve 2G31-F004 Caused Valve to Close.Caused by Failure of Fenwal Type 56100 Temp Switch.Switch Repaired & Recalibr + (ML20097D686)
- 05000251/LER-1984-017-01, :on 840807,Unit 4 Experienced Reactor Trip Coincident W/Loss of Unit 3 Startup Transformer.Caused by Incorrect Switching Order + (ML20097D692)
- 05000249/LER-1983-035-03, /03X-1:on 831004,during Drywell Insp,Water Observed Leaking from Recirculation Pump Bowl Drain A. Probably Caused by Socket Weld Joint Bottoming Out.Affected Piping Replaced During Outage + (ML20097D696)
- ML20097D700 + (ML20097D700)
- ML20097D707 + (ML20097D707)
- 05000289/LER-1992-001, :on 920122,inadvertent Emergency Feedwater Initiation Occurred During Planned Maint.Caused by Installation Error.Wire Errors Affecting Sys Operation Corrected + (ML20097D720)
- ML20097D732 + (ML20097D732)
- ML20097D733 + (ML20097D733)
- 05000219/LER-1992-005, :on 920503,reactor Scram & Subsequent Engineered Safety Features Sys Actuations Occurred Due to Turbine Load Rejection.Util Personnel Inspected Offsite Power Lines + (ML20097D739)
- ML20097D740 + (ML20097D740)
- HL-5103, Comment Supporting NEI Comments on Petition for Rulemaking PRM-50-63 Re Planning Std for Protective Actions for General Public Includes Stockpile or Predistribution of Ki for Prophylactic Use + (ML20097D744)
- ML20097D746 + (ML20097D746)
- LD-92-072, Forwards Description of Human Reliability Analysis Methodology Used in Probabilistic Risk Assessment + (ML20097D748)
- ML20097D757 + (ML20097D757)
- ML20097D758 + (ML20097D758)
- ML20097D761 + (ML20097D761)
- ML20097D772 + (ML20097D772)
- ML20097D777 + (ML20097D777)
- ML20097D800 + (ML20097D800)
- ML20097D813 + (ML20097D813)
- ML20097D814 + (ML20097D814)
- ML20097D818 + (ML20097D818)
- ML20097D830 + (ML20097D830)
- ML20097D834 + (ML20097D834)
- L-96-002, Forwards Revised Monthly Operating Repts for Point Beach Nuclear Plant Units 1 & 2 for Jul,Dec & Mar 1995 + (ML20097D835)
- ML20097D843 + (ML20097D843)
- 3F0296-04, Forwards Response to NRC Re Violations Noted in Insp Rept 50-302/95-16.Corrective Actions:Fan Speed Has Been Reduced to Correct Problem + (ML20097D844)
- ML20097D848 + (ML20097D848)
- 0CAN059208, Submits Addl QA Audit Info on Procedure Reviews,In Ref to 920414,requesting That Proposed Changes to QA Manual - Operations Be Approved to Change Commitment of ANSI N18.7-1976 Re Conducting Biennial Procedure Reviews + (ML20097D853)
- ML20097D854 + (ML20097D854)
- ML20097D858 + (ML20097D858)
- 3F0692-07, Provides Response to NRC Ltr Re Reactor Bldg Equipment Relocation & Environ Qualification + (ML20097D860)
- ML20097D861 + (ML20097D861)
- ML20097D863 + (ML20097D863)
- ML20097D868 + (ML20097D868)
- 05000454/LER-1995-001, Informs That SER Issued Using LER 95-001 & Will Not Be Deemed as Ler.Lers 95-007 & 95-009 Will Not Be Used for Docket 50-454.LERs 95-003 Will Not Be Used for Docket 50-455 + (ML20097D869)
- ML20097D871 + (ML20097D871)
- ML20097D876 + (ML20097D876)
- ML20097D878 + (ML20097D878)
- JAFP-84-0823, Effluent & Waste Disposal Semiannual Rept for Jan-June 1984 + (ML20097D893)
- ML20097D911 + (ML20097D911)
- ML20097D913 + (ML20097D913)
- ML20097D916 + (ML20097D916)
- 3F0296-03, Forwards ISI Relief Request 95-050,which Requests Approval for Performing Limited Exam of Two Core Flood Nozzle Inner Radius Sections + (ML20097D922)
- ML20097D923 + (ML20097D923)
- ND-20-0107, ITAAC Closure Notification on Completion of ITAAC Item 3.3.00.06a (Index Number 787) + (ML20097D924)
- ML20097D927 + (ML20097D927)
- ML20097D941 + (ML20097D941)
- ML20097D945 + (ML20097D945)
- ML20097D950 + (ML20097D950)
- ML20097D975 + (ML20097D975)