- U-602493, Provides Revised Response to Unresolved Item Noted in Insp Rept 50-461/95-08.Correct USAR Page for Proposed USAR Rev Re Util Commitment to ANSI N45.2.6-1978, Qualifications of Insp,Exam & Testing Personnel for NPPs Encl + (ML20092C679)
- ML20092C680 + (ML20092C680)
- ML20092C681 + (ML20092C681)
- ML20092C689 + (ML20092C689)
- 05000282/LER-1995-010, :on 950804,discovered Deficiencies in Flow Testing of RHR Sys.Caused by Deficient Procedure Which Failed to Consider Effect of Recirculation Line Downstream of Flow Orifice.Procedure Changes Will Be Made + (ML20092C699)
- ML20092C700 + (ML20092C700)
- ML20092C717 + (ML20092C717)
- ML20092C733 + (ML20092C733)
- ML20092C737 + (ML20092C737)
- ML20092C745 + (ML20092C745)
- ML20092C746 + (ML20092C746)
- ML20092C760 + (ML20092C760)
- ML20092C762 + (ML20092C762)
- ST-HL-AE-3959, Forwards Objectives for 1992 Graded Emergency Preparedness Exercise on 920429 for Review & comment.W/920207 Release Memo + (ML20092C764)
- ML20092C768 + (ML20092C768)
- 05000277/LER-1984-009, :on 840516,during Refueling Outage,False lo-lo Reactor Level Initiation Signal Caused HPCI & RCIC to Attempt to Start When Both Power Supplies for ECCS Channel a Logic Feeds Removed.Supply Feeds Restored + (ML20092C770)
- ML20092C771 + (ML20092C771)
- BECO-84-085, Forwards Final Rept, 1984 Remote Visual Exam of Core Spray Sparger Sys of Pilgrim Nuclear Power Station,Unit 1, Per IE Bulletin 80-13 & Util .Exam Revealed No Change in Conditions Reported During 1981 Exams + (ML20092C772)
- ML20092C777 + (ML20092C777)
- ML20092C779 + (ML20092C779)
- ML20092C780 + (ML20092C780)
- ML20092C791 + (ML20092C791)
- ML20092C797 + (ML20092C797)
- ML20092C798 + (ML20092C798)
- ML20092C799 + (ML20092C799)
- NG-95-2723, Comment Supporting Revised NRC SALP Program + (ML20092C803)
- ML20092C804 + (ML20092C804)
- ML20092C805 + (ML20092C805)
- ML20092C806 + (ML20092C806)
- ML20092C808 + (ML20092C808)
- ML20092C809 + (ML20092C809)
- ML20092C811 + (ML20092C811)
- ML20092C812 + (ML20092C812)
- ML20092C814 + (ML20092C814)
- ML20092C815 + (ML20092C815)
- ML20092C816 + (ML20092C816)
- ML20092C817 + (ML20092C817)
- ML20092C818 + (ML20092C818)
- ML20092C819 + (ML20092C819)
- ML20092C821 + (ML20092C821)
- ML20092C823 + (ML20092C823)
- ML20092C827 + (ML20092C827)
- ML20092C828 + (ML20092C828)
- ML20092C831 + (ML20092C831)
- ML20092C832 + (ML20092C832)
- ML20092C836 + (ML20092C836)
- ML20092C838 + (ML20092C838)
- ML20092C843 + (ML20092C843)
- ML20092C845 + (ML20092C845)
- ML20092C847 + (ML20092C847)
- 05000387/LER-1984-012-01, Revised LER 84-012-01:on 840225,due Date & Violation Date Inadvertently Omitted from Cover Sheet of Quarterly Surveillance Procedure SI-072-301.Administrative Procedures Revised + (ML20092C848)