Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000286/LER-1984-001-01, :on 840125,w/reactor in Hot Shutdown,Code Safety Valve MS-45 on Main Steam Header 34 Opened Momentarily.Caused by High Differential Pressure Lifting Valve.Valve Reset & Tested + (ML20081C854)
- DCL-84-086, Final Deficiency Rept Re Malfunction of Valve Operator Mfg by Limitorque.Initially Reported on 830627.Existing Screws Will Be Replaced on Affected Valves Prior to Fuel Load.Maint Procedures Modified + (ML20081C856)
- 05000366/LER-1983-083-03, /03L-0:on 830928,both Recirculation Pumps Tripped. Caused by Packing Binding Inside Reactor Level Instrument 2B21-N031B Low Pressure Side Manifold Isolation Valve.Valve Operated open-to-close Then close-to-open + (ML20081C857)
- ML20081C858 + (ML20081C858)
- ML20081C859 + (ML20081C859)
- 05000286/LER-1984-003-01, :on 840128,automatic Safety Injection Signal Actuated on High Differential Steam Line Pressure.Caused by Code Safety Valve MS-45 on Main Header 34 Lifting Momentarily.Valve Reset + (ML20081C861)
- ML20081C862 + (ML20081C862)
- ML20081C863 + (ML20081C863)
- W3P83-2529, Responds to NRC Re IE Emergency Preparedness Appraisal Rept 50-382/83-08.Emergency Plan & Implementing Procedures Will Be Revised to Reflect Flow of Authority & Responsibility + (ML20081C865)
- ML20081C866 + (ML20081C866)
- 05000368/LER-1983-042-03, /03L-0:on 830913 & 15,junction Box for Conduits in Fire Zone 2150 Discovered Open & Gap Between Floor & Fire Doors 340 & 267 Exceeded Acceptance Criteria.Caused by Exclusion of Zones from Installation Specs + (ML20081C869)
- ML20081C871 + (ML20081C871)
- ML20081C875 + (ML20081C875)
- ML20081C876 + (ML20081C876)
- ML20081C878 + (ML20081C878)
- 05000361/LER-1984-005-01, :on 840127,while in Mode 5,w/purge/vent Stack wide-range Monitor 3RT-7865 & Flow Rate Monitor Out of Svc for Installation of Noise Suppression Circuit,Flow Rate Estimates Not Performed as Required + (ML20081C880)
- ML20081C883 + (ML20081C883)
- ML20081C884 + (ML20081C884)
- ML20081C897 + (ML20081C897)
- PY-CEI-NRR-0075, Provides Clarification on Quencher tie-down Loads.Design Dynamic Stress from Bending Moment on Quencher Arm Greater than 5,000 Psi.Facility Design Meets Acceptance Criteria + (ML20081C900)
- ML20081C906 + (ML20081C906)
- ML20081C907 + (ML20081C907)
- ML20081C908 + (ML20081C908)
- ML20081C921 + (ML20081C921)
- ML20081C922 + (ML20081C922)
- ML20081C923 + (ML20081C923)
- ML20081C927 + (ML20081C927)
- W3P84-0591, Forwards 13 Ltrs of Agreement from Chemical Industries within 5 Miles of Facility Re Toxic Chemicals,Per Emergency Plan + (ML20081C931)
- ML20081C936 + (ML20081C936)
- 05000395/LER-1983-114-03, /03L-0:on 831004,steam Generator C Pressure Indicator 494 Declared Inoperable Due to Spiking Causing Various Alarms & Bistable to Actuate.Caused by Faulty Electronic Loop Power Supply Card + (ML20081C940)
- 05000327/LER-1984-014, :on 840214,high Radiation Alarm Actuated, Causing Containment Ventilation Isolation to Occur.Caused by Voltage Spike Resulting in Electromagnetic Interference. Alarm Reset & Monitor Returned to Svc + (ML20081C943)
- ML20081C944 + (ML20081C944)
- 05000395/LER-1983-113-03, /03L-0:on 830924,operator Found Personnel Escape Door Hatch Outer Door Hard to Operate & Unsecured.Caused by Sheared Right Angle Gear Drive Pin.Both Doors Locked & Seal Leak Tested Satisfactorily + (ML20081C945)
- ML20081C951 + (ML20081C951)
- DCL-84-091, Responds to NRC Re Violations Noted in IE Insp Rept 50-275/83-39.Corrective Actions:Area Permits for Welding Posted to Identify Generic Requirements on Area Basis & Util Inspector Assigned to Assist Fire Marshall + (ML20081C954)
- ML20081C956 + (ML20081C956)
- 05000348/LER-1984-003-01, :on 840218,detensioning of Reactor Vessel Head Studs Begun W/Rcs Boron Concentration Greater than Tech Spec Limits.Caused by Misinterpretation of Tech Specs.Personnel Counseled + (ML20081C959)
- ML20081C960 + (ML20081C960)
- ML20081C966 + (ML20081C966)
- NG-95-0815, Responds to NRC RAI Re Removal of 17 Valves from DAEC GL 89-10 MOV Program + (ML20081C967)
- ML20081C969 + (ML20081C969)
- ML20081C972 + (ML20081C972)
- ML20081C978 + (ML20081C978)
- ML20081C982 + (ML20081C982)
- NG-95-0286, Application for Amend to License DPR-49,consisting of Proposed Change RTS-279 to TS to Remove Redundant LCOs & SRs for Containment Hydrogen & Oxygen Monitors in TS + (ML20081C984)
- ML20081C988 + (ML20081C988)
- ML20081C989 + (ML20081C989)
- ML20081C993 + (ML20081C993)
- RBG-41270, Forwards Certificates of Insurance Issued to Entergy Operations,Inc,As Evidence of Primary & Excess Onsite Property Damage Insurance for River Bend Station,Per 10CFR50.54(w)(3) + (ML20081C998)
- TXX-4130, Forwards Vibration Instrumentation Plan.Plan Closes Out Sser 3 Confirmatory Issue C6 Re Pressure of Flow Induced Tube Failure in Model D-4 & D-5 Steam Generators + (ML20081C999)
- ML20081D002 + (ML20081D002)