- 05000275/LER-1983-007, Updated LER 83-007/01T-1:on 830509,during Welding of Reinforcement Pad on Branch Connection to Loop C Component Cooling Water Sys,Water Leaked from Weld Area.Caused by Grinding on Fillet Overweld.Overweld Removed + (ML20080Q172)
- AECM-82-581, Confirms Installation of Mechanical Pressure Gauge on Automatic Depressurization Sys Air Makeup Line & Performance of Associated Surveillance + (ML20080Q174)
- ML20080Q176 + (ML20080Q176)
- ML20080Q184 + (ML20080Q184)
- ML20080Q185 + (ML20080Q185)
- ML20080Q191 + (ML20080Q191)
- ML20080Q194 + (ML20080Q194)
- ML20080Q204 + (ML20080Q204)
- ML20080Q213 + (ML20080Q213)
- FVY-83-108, Forwards Technical Rept Mark I Containment Program Plant- Unique Analysis Rept of Torus Attached Piping for Vermont Yankee Nuclear Power Plant + (ML20080Q218)
- ML20080Q224 + (ML20080Q224)
- L-2020-048, Individual Monitoring Report + (ML20080Q228)
- ML20080Q234 + (ML20080Q234)
- ML20080Q236 + (ML20080Q236)
- ML20080Q239 + (ML20080Q239)
- 05000346/LER-1983-048-03, /03L-0:on 830901,four HPI Stop Check Valves Found Malfunctioning,In Violation of Tech Specs.Caused by Design Deficiency.Disk in HP49 Replaced w/33 Degree Seat Angle Design + (ML20080Q242)
- U-602426, Ro:On 950301,plant Was Operating at Approx 75% Fire Was Reported in a turbine-driven Reactor Feed Pump Room + (ML20080Q249)
- ML20080Q261 + (ML20080Q261)
- ML20080Q263 + (ML20080Q263)
- ML20080Q266 + (ML20080Q266)
- 05000362/LER-1983-055-03, /03L-0:on 830826,core Protection Channel a Declared Inoperable & Bypassed Due to Failed High Reactor Coolant Cold Leg Temp Input.Caused by Failed Open Resistance Temp Detector 3TE-9179-1.Detector Replaced + (ML20080Q271)
- ML20080Q273 + (ML20080Q273)
- ML20080Q276 + (ML20080Q276)
- 05000306/LER-1983-020-03, /03L-0:on 830829,maint Air Lock Door Exhibited Leakage of 21,000 Sccm Exceeding Tech Spec Limit.Caused by Deterioration of Grafoil Packing at Inboard Shaft Seals. Packing Will Be Replaced Prior to Startup + (ML20080Q278)
- ML20080Q280 + (ML20080Q280)
- B11029, Forwards Probabilistic Safety Study Input Listings for Listed Computer Codes/Cases.W/O Encl + (ML20080Q283)
- 05000315/LER-1983-089-03, /03L-0:on 830628,31-day Visual Verification of Blind Flange Over Fuel Transfer Tube CPN-1 Deleted from All Revs.Caused by Verification Deleted in 750407 Rev.Change Sheet Written to Include CPN-1 in Procedure + (ML20080Q284)
- ML20080Q286 + (ML20080Q286)
- ML20080Q289 + (ML20080Q289)
- AECM-83-0652, Advises That Due to Uncertainty in Instrumentation Availability & Manpower Resources,Instrumentation Necessary to Meet Reg Guide 1.97 Requirements Will Be Implemented by Third Refueling Outage Per Suppl 1 to NUREG-0737 + (ML20080Q296)
- ML20080Q297 + (ML20080Q297)
- ML20080Q299 + (ML20080Q299)
- 05000348/LER-1983-038, Forwards LERs 83-060/03L-0,83-061/03L-0,83-037/03L-0 & 83-038/03L-0.W/o LER 83-038/03L-0 + (ML20080Q300)
- 05000361/LER-1983-076-03, Pilot Flames of Trains a & B of Toxic Gas Isolation Sys Butane/Propane Monitors Found Extinguished.Cause of Pilot Flameout Unknown.Failure of Sys Caused by Low Alarm Setpoint.Pilot Flames Restored + (ML20080Q304)
- ML20080Q307 + (ML20080Q307)
- ML20080Q311 + (ML20080Q311)
- B11030, Forwards Boron Dilution Analysis,Per Reg Guide 1.70 & NUREG-0880,for Failures in Chemical & Vol Control Sys,Based on Westinghouse STS Setpoints & Limits.No Design Changes Recommended or Implied.W/O Encl + (ML20080Q312)
- ML20080Q316 + (ML20080Q316)
- ML20080Q318 + (ML20080Q318)
- ML20080Q321 + (ML20080Q321)
- 05000348/LER-1983-060-03, /03L-0:on 830912,instrumentation Channel for Flow Transmitter FT-415 Declared Inoperable Due to Erratic Indications.Caused by Failure of Nlp Card.Card Replaced + (ML20080Q328)
- ML20080Q330 + (ML20080Q330)
- ML20080Q335 + (ML20080Q335)
- ML20080Q339 + (ML20080Q339)
- ML20080Q340 + (ML20080Q340)
- ML20080Q342 + (ML20080Q342)
- ML20080Q344 + (ML20080Q344)
- ML20080Q349 + (ML20080Q349)