Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20080Q087 + (ML20080Q087)
- ML20080Q091 + (ML20080Q091)
- ML20080Q092 + (ML20080Q092)
- 05000362/LER-1983-066-03, /03L-0:on 830829 & 31,while in Mode 2,control Element Assembly Calculator 2 Experienced Excessive Auto Restarts.First Event Caused by Faulty Central Processing Unit Board.Cause for Second Event Unknown + (ML20080Q094)
- ML20080Q103 + (ML20080Q103)
- ML20080Q105 + (ML20080Q105)
- ML20080Q106 + (ML20080Q106)
- ML20080Q108 + (ML20080Q108)
- ML20080Q109 + (ML20080Q109)
- 05000346/LER-1983-047-03, /03L-0:on 830831,during Independent Offsite Ac Source Bus Transfer Procedure,Automatic Unit Power Supply to Each 345 Kv Transmission Line Failed.Caused by Dirt in Source Selector Switch + (ML20080Q125)
- ML20080Q126 + (ML20080Q126)
- W3P83-3318, Advises That Util Will Participate W/Inpo & C-E Owners Group in Addressing Certain Requirements of Generic Ltr 83-28, Required Actions Based on Generic Implication of Salem ATWS Events. Initial Response Expected by 840115 + (ML20080Q127)
- 05000315/LER-1983-091-03, /03L-0:on 830829,during Refueling Outage,Fire Door Leading to Contractor Access Area Inadvertently Damaged When Door Closed W/Piece of Steel Between Door Jam & Edge of Door.Caused by Personnel Error.Door Repaired + (ML20080Q132)
- ML20080Q135 + (ML20080Q135)
- ML20080Q138 + (ML20080Q138)
- ML20080Q142 + (ML20080Q142)
- RA-95-0020, 1994 Personnel Exposure & Monitoring Rept + (ML20080Q144)
- ML20080Q148 + (ML20080Q148)
- ML20080Q151 + (ML20080Q151)
- ML20080Q153 + (ML20080Q153)
- ML20080Q164 + (ML20080Q164)
- 05000275/LER-1983-007, Updated LER 83-007/01T-1:on 830509,during Welding of Reinforcement Pad on Branch Connection to Loop C Component Cooling Water Sys,Water Leaked from Weld Area.Caused by Grinding on Fillet Overweld.Overweld Removed + (ML20080Q172)
- AECM-82-581, Confirms Installation of Mechanical Pressure Gauge on Automatic Depressurization Sys Air Makeup Line & Performance of Associated Surveillance + (ML20080Q174)
- ML20080Q176 + (ML20080Q176)
- ML20080Q184 + (ML20080Q184)
- ML20080Q185 + (ML20080Q185)
- ML20080Q191 + (ML20080Q191)
- ML20080Q194 + (ML20080Q194)
- ML20080Q204 + (ML20080Q204)
- ML20080Q213 + (ML20080Q213)
- FVY-83-108, Forwards Technical Rept Mark I Containment Program Plant- Unique Analysis Rept of Torus Attached Piping for Vermont Yankee Nuclear Power Plant + (ML20080Q218)
- ML20080Q224 + (ML20080Q224)
- L-2020-048, Individual Monitoring Report + (ML20080Q228)
- ML20080Q234 + (ML20080Q234)
- ML20080Q236 + (ML20080Q236)
- ML20080Q239 + (ML20080Q239)
- 05000346/LER-1983-048-03, /03L-0:on 830901,four HPI Stop Check Valves Found Malfunctioning,In Violation of Tech Specs.Caused by Design Deficiency.Disk in HP49 Replaced w/33 Degree Seat Angle Design + (ML20080Q242)
- U-602426, Ro:On 950301,plant Was Operating at Approx 75% Fire Was Reported in a turbine-driven Reactor Feed Pump Room + (ML20080Q249)
- ML20080Q261 + (ML20080Q261)
- ML20080Q263 + (ML20080Q263)
- ML20080Q266 + (ML20080Q266)
- 05000362/LER-1983-055-03, /03L-0:on 830826,core Protection Channel a Declared Inoperable & Bypassed Due to Failed High Reactor Coolant Cold Leg Temp Input.Caused by Failed Open Resistance Temp Detector 3TE-9179-1.Detector Replaced + (ML20080Q271)
- ML20080Q273 + (ML20080Q273)
- ML20080Q276 + (ML20080Q276)
- 05000306/LER-1983-020-03, /03L-0:on 830829,maint Air Lock Door Exhibited Leakage of 21,000 Sccm Exceeding Tech Spec Limit.Caused by Deterioration of Grafoil Packing at Inboard Shaft Seals. Packing Will Be Replaced Prior to Startup + (ML20080Q278)
- ML20080Q280 + (ML20080Q280)
- B11029, Forwards Probabilistic Safety Study Input Listings for Listed Computer Codes/Cases.W/O Encl + (ML20080Q283)
- 05000315/LER-1983-089-03, /03L-0:on 830628,31-day Visual Verification of Blind Flange Over Fuel Transfer Tube CPN-1 Deleted from All Revs.Caused by Verification Deleted in 750407 Rev.Change Sheet Written to Include CPN-1 in Procedure + (ML20080Q284)
- ML20080Q286 + (ML20080Q286)
- ML20080Q289 + (ML20080Q289)
- AECM-83-0652, Advises That Due to Uncertainty in Instrumentation Availability & Manpower Resources,Instrumentation Necessary to Meet Reg Guide 1.97 Requirements Will Be Implemented by Third Refueling Outage Per Suppl 1 to NUREG-0737 + (ML20080Q296)