Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20077H853 + (ML20077H853)
- ML20077H856 + (ML20077H856)
- 1CAN078307, Monthly Operating Rept for June 1983.W/corrected + (ML20077H860)
- ML20077H863 + (ML20077H863)
- ML20077H878 + (ML20077H878)
- ML20077H880 + (ML20077H880)
- ML20077H891 + (ML20077H891)
- 05000302/LER-1983-025-01, /01T-0:on 830722,CR-3 Administrative Controls Found Inadequate to Preclude Overloading of Cable Tray Supports.Caused by Procedural Inadequacy.Appropriate Procedures Introduced.Supports Modified + (ML20077H893)
- ML20077H899 + (ML20077H899)
- ML20077H902 + (ML20077H902)
- 05000272/LER-1983-030-03, /03L-0:on 830710,emergency Diesel Generator 1A Tripped During Routine Surveillance.Caused by Security Guard Inadvertently Striking Emergency Trip Button.Personnel Eliminated from Security Force + (ML20077H903)
- AECM-83-0449, Forwards Proposed Tech Spec Changes Resulting from Review of Tech Specs & Surveillance Procedures.Changes Will Enhance Clarity & Provide Consistency W/Plant Design & Operation + (ML20077H906)
- ML20077H908 + (ML20077H908)
- ML20077H909 + (ML20077H909)
- ML20077H910 + (ML20077H910)
- ML20077H914 + (ML20077H914)
- ML20077H916 + (ML20077H916)
- ML20077H917 + (ML20077H917)
- ML20077H921 + (ML20077H921)
- ML20077H924 + (ML20077H924)
- 05000324/LER-1983-062-03, /03L-0:on 830707,performance of Primary Containment Volumetric Average Air Temp Test PT-1612 Revealed Temp Exceeded Tech Spec Limit of 135 F.Caused by Seasonal Ambient Temps & Plant Evolutions + (ML20077H926)
- 05000387/LER-1983-102-03, /03L-0:on 830708,RCIC Turbine Exhaust Pressure Channel a Tripped But Could Not Be Reset.Caused by Unadjusted Channel a Microswitch.Microswitch Adjusted + (ML20077H927)
- ML20077H928 + (ML20077H928)
- ML20077H931 + (ML20077H931)
- PLA-1762, Interim Deficiency Rept Re Scram Discharge Vol Vent,Drain Valve & Water Hammer Loads.Initially Reported on 830628. Performance of Analysis to Determine Load & Impact Underway. Also Reported Per Part 21 + (ML20077H932)
- ML20077H933 + (ML20077H933)
- ML20077H934 + (ML20077H934)
- ML20077H935 + (ML20077H935)
- W3P83-2269, Comments on Fire Water Sys Connection (Tertiary Backup) to Lubrication & Cooling Water for Circulating Water Pump. Three-inch Connection Is Tertiary Backup Means of Supply to Circulating Water Sys Which Is Normally Closed + (ML20077H936)
- ML20077H937 + (ML20077H937)
- JAFP-83-0817, Monthly Operating Rept for Jul 1983 + (ML20077H940)
- ML20077H942 + (ML20077H942)
- 05000289/LER-1983-016-03, /03L-0:on 830703,liquid Effluent Radiation Monitor RM-L7 Had No Sample Flow Through Monitor.Caused by Mechanical Seizure.Pump & Motor Replaced + (ML20077H951)
- ML20077H952 + (ML20077H952)
- ML20077H954 + (ML20077H954)
- 05000387/LER-1983-099-03, /03L-0:on 830629,RCIC Turbine Exhaust Valve Failed Local Leak Rate Testing.Caused by Tolerances Between Hard & Resilient Seats W/O Good Seating Surface.Resilient Seat Replaced + (ML20077H955)
- ML20077H956 + (ML20077H956)
- 05000280/LER-1983-028-03, /03L-0:on 830702,carbon Dioxide Tank Level Discovered to Be Less than 75%.Caused by Operator Not Monitoring Purge.Fire Watches Established & Tank Refilled to Required Level + (ML20077H958)
- 05000280/LER-1983-029-03, /03L-0:on 830714,control Rods Powered from Cabinet 2BD Would Not Respond During PT-6.Caused by Blown Fuse in three-phase Power Supply for Cabinet 2BD.Fuse Replaced & Rod Movement Verified + (ML20077H959)
- ML20077H961 + (ML20077H961)
- ML20077H963 + (ML20077H963)
- ML20077H964 + (ML20077H964)
- 05000311/LER-1983-034-03, /03L-0:on 830708,surveillance Testing Revealed Excessive Seal Leakage on Inner Door of 130-ft Elevation Containment Air Lock.Caused by Rapid Operation of Door So Door Seals Unevenly Seated in Seal Groove + (ML20077H966)
- ML20077H967 + (ML20077H967)
- ML20077H969 + (ML20077H969)
- ML20077H970 + (ML20077H970)
- ML20077H971 + (ML20077H971)
- ML20077H972 + (ML20077H972)
- ML20077H973 + (ML20077H973)
- ML20077H975 + (ML20077H975)
- ML20077H976 + (ML20077H976)