Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20076F357 + (ML20076F357)
- ML20076F360 + (ML20076F360)
- 05000361/LER-1983-049-03, /03L-0:on 830429,emergency Chiller E-336 (Train a) Failed to Start Following Invalid Tgis.Caused by Misalignment of Supply Breaker.Breaker Aligned + (ML20076F365)
- ML20076F368 + (ML20076F368)
- ML20076F369 + (ML20076F369)
- 05000416/LER-1983-021-01, /01T-0:on 830519,while in Cold Shutdown,Standby Gas Treatment Sys Flow Monitoring Instrumentation Found Reading in Error.Caused by Incorrect Calibr Range.Correct Calibr Ranges Issued + (ML20076F375)
- ML20076F376 + (ML20076F376)
- 0CAN068304, Responds to IE Bulletin 83-03, Check Valve Failures in Raw Water Cooling Sys of Diesel Generators. Check Valves Described in Bulletin Not Employed at Facilities.Bulletin Not Applicable + (ML20076F380)
- ML20076F383 + (ML20076F383)
- ML20076F393 + (ML20076F393)
- ML20076F395 + (ML20076F395)
- ML20076F399 + (ML20076F399)
- ML20076F405 + (ML20076F405)
- ML20076F406 + (ML20076F406)
- ML20076F410 + (ML20076F410)
- 05000395/LER-1983-044-01, /01T-0:on 830523,steam Generator B Feedwater Flow Transmitter FT-486 Did Not Respond to Change in Feedwater Flow.Caused by Personnel Error in Not Properly Identifying Transmitter on Tagout Sheet + (ML20076F412)
- ML20076F416 + (ML20076F416)
- ML20076F422 + (ML20076F422)
- L-83-340, Responds to IE Bulletin 79-14, Seismic Analysis for As- Built Safety-Related Piping Sys. Program Verifying Piping Geometry,Including Support/Restraint/Valve Locations Re Piping Sys & Restraint Function,Complete + (ML20076F425)
- L-94-030, Monthly Operating Repts for Sept 1994 for Point Beach Nuclear Plant + (ML20076F429)
- ML20076F440 + (ML20076F440)
- ML20076F443 + (ML20076F443)
- JPN-94-051, Forwards Application for Amend to License DPR-59,changing TS Re Safety/Relief Valve Testing Requirements + (ML20076F450)
- 1CAN088309, Provides Current Status of Dresser Safety Valve Settings. Valve Settings Are -48,-93,+5 & W/No Lift Restriction. Adjustments Assure Safety Valves Will Achieve 100% of ASME Rated Capacity + (ML20076F451)
- 05000260/LER-1983-041-03, /03L-0:on 830721,following Preconditioning Operations,Tech Spec Limit for Linear Heat Generation Rate Exceeded in Four Nodes.Caused by Insufficient Communication Between Operators During Flow Increases + (ML20076F453)
- ML20076F454 + (ML20076F454)
- AECM-83-0477, RO 83-070/0:on 830716,listed Fire Rated Doors Blocked Open to Support Planned Maint Activities in Auxiliary & Control Bldgs.Fire Watches Established.Doors Expected to Be Restored by 830930 + (ML20076F455)
- ML20076F458 + (ML20076F458)
- ML20076F459 + (ML20076F459)
- ML20076F461 + (ML20076F461)
- ML20076F462 + (ML20076F462)
- ML20076F463 + (ML20076F463)
- W3P83-2783, Forwards Vital Equipment Block Diagram,Per 830725 Request. Diagram Withheld + (ML20076F464)
- IR 05000346/2020301 + (ML20076F465)
- 05000331/LER-1983-027-03, /03L-0:on 830803,RCIC Discharge Pressure Indicator Found Indicating Improperly.Caused by out-of-calibr Pressure Transmitter.Transmitter Calibr + (ML20076F466)
- ML20076F468 + (ML20076F468)
- ML20076F470 + (ML20076F470)
- ML20076F473 + (ML20076F473)
- 05000339/LER-1983-058-03, /03L-0:on 830717,18 & 25,individual Rod Position Indicators Deviated from Group Demand Position.Caused by Instrument Drift,Generic to Westinghouse Analog Position Sys.Channels Recalibr + (ML20076F475)
- 05000302/LER-1983-028-03, /03L-0:on 830722,HPI Pump Motor (MUP-1C) Failed. Caused by Personnel Inadvertently Securing Cooling Water Supplied by DCP-1B.Precautionary Tags Placed on Control Board.Operators Cautioned + (ML20076F484)
- ML20076F491 + (ML20076F491)
- ML20076F492 + (ML20076F492)
- 05000315/LER-1983-068-03, /03L-0:on 830715,ice Condenser Intermediate Deck Door Found Frozen Shut.Caused by Failed Defrost Heater for Handling Unit 3-7A.Ice Removed & Defrost Heater Replaced + (ML20076F496)
- ML20076F499 + (ML20076F499)
- ML20076F500 + (ML20076F500)
- 05000338/LER-1983-052-03, /03L-0:on 830729,individual Rod Position Indication for Rod J-13 Indicated 110 Steps Instead of Required 228.Caused by Bad Connection of Signal Conditioning Module.Connection Reseated + (ML20076F502)
- ML20076F503 + (ML20076F503)
- 05000261/LER-1983-020-01, /01T-0:on 830803,w/unit at 79% Power,Current Tech Spec Cooldown Curves Determined to Be in Error,Per Review of New Draft Curves Based on Analysis of Reactor Vessel Surveillance Capsule.Curves Revised on 830804 + (ML20076F504)
- 05000278/LER-1994-004-02, :on 940924,HPIS Inoperable When Steam Supply Valve Was Closed to Isolate Leak.Caused by Packing Leak on MO-3-23-15.Corrective Actions Being Developed.W/Undated Ltr + (ML20076F507)
- ML20076F508 + (ML20076F508)
- 05000324/LER-1983-068-03, /03L-0:on 830725,drywell Equipment Drain Sump Flow Square Root Signal Converter 2-G16-FY-K600 Found Functioning Out of Tolerances.Caused by Instrument Drift. Instrument Will Be Replaced + (ML20076F515)