Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20073P925 + (ML20073P925)
- ML20073P927 + (ML20073P927)
- ML20073P930 + (ML20073P930)
- ML20073P933 + (ML20073P933)
- ML20073P936 + (ML20073P936)
- ML20073P940 + (ML20073P940)
- ML20073P947 + (ML20073P947)
- ML20073P949 + (ML20073P949)
- ML20073P950 + (ML20073P950)
- ML20073P952 + (ML20073P952)
- ML20073P955 + (ML20073P955)
- ML20073P956 + (ML20073P956)
- ML20073P962 + (ML20073P962)
- ML20073P974 + (ML20073P974)
- ML20073P975 + (ML20073P975)
- NRC-83-0022, Forwards Containment Recirculation Sump Hydraulic Performance,Snupps. Redesigned Sumps Have Satisfactory Hydraulic Performance Under Design Conditions of Restricted Flow & Partial Screen Blockages + (ML20073P977)
- ML20073P981 + (ML20073P981)
- ML20073P983 + (ML20073P983)
- ML20073P985 + (ML20073P985)
- ML20073P987 + (ML20073P987)
- ML20073P989 + (ML20073P989)
- ML20073P991 + (ML20073P991)
- ML20073P999 + (ML20073P999)
- ML20073Q002 + (ML20073Q002)
- RBG-14-861, Forwards Mission 289 Color Infrared Imagery,Landsat Imagery, Lineament Interpretation of Landsat Images & Us Dept of Agriculture Index Photo Mosaics,Per 811231 & 820615 Requests.W/O Encl + (ML20073Q006)
- RBG-14-856, Interim Deficiency Rept DR-103 Re Linear Indications Found in Lifting Lugs on Containment Dome.Initially Reported on 830325.Investigation Incomplete.Next Rept Expected by 830617 + (ML20073Q010)
- ML20073Q012 + (ML20073Q012)
- 05000321/LER-1983-038, Forwards LER 83-038/03L-0 + (ML20073Q015)
- ML20073Q018 + (ML20073Q018)
- 05000321/LER-1983-038-03, /03L-0:on 830322,inspectors Discovered I Beam in Torus Room Supported by C Clamps,Contrary to Tech Spec Requirements.Cause Unknown.Clamp Removed + (ML20073Q021)
- ML20073Q023 + (ML20073Q023)
- B10737, Submits Results of Leakage Measurements Completed on 830407, Per Amend 83 to License DPR-65 Re Deferred Inservice Insp Requirements.Steam Generator Leakage Rates Acceptable + (ML20073Q025)
- ML20073Q026 + (ML20073Q026)
- 05000369/LER-1983-014, Forwards LER 83-014/03L-0 + (ML20073Q032)
- ML20073Q036 + (ML20073Q036)
- AECM-83-0248, RO 83-022/0:on 830317,fire Break in Cable Tray at 177-ft Elevation in Control Room Removed for Implementation of Design Change Work Package.Hourly Fire Watch Established. Break Will Be Restored Upon Completion of Work + (ML20073Q038)
- 05000369/LER-1983-014-03, /03L-0:on 830303,routine Surveillance on Conventional Waste Water Sys Radiation Monitor 1EMF-31 Found Channel Out of Tolerance.Caused by Cracked Detector Crystal. Crystal Replaced W/High Temp Crystal + (ML20073Q042)
- ML20073Q044 + (ML20073Q044)
- ML20073Q045 + (ML20073Q045)
- ML20073Q051 + (ML20073Q051)
- AECM-83-0250, RO 83-020/0:on 830315 & 17,supervisory Alarms for Fire Doors Alarmed & Would Not Reset.First Instance Caused by Faulty Spring Door Hinges.Hinges Replaced.Second Instance Caused by Damaged Limit Switch Actuator Arms + (ML20073Q052)
- ML20073Q056 + (ML20073Q056)
- 05000395/LER-1983-030, Forwards LER 83-030/03L-0.Detailed Event Analysis Encl + (ML20073Q060)
- ML20073Q063 + (ML20073Q063)
- ML20073Q065 + (ML20073Q065)
- 05000395/LER-1983-030-03, /03L-0:on 830324,reactor Bldg Fire Detection Zones Ooo & Ppp Declared Inoperable When Power Supply Breaker Opened.Caused by Faulty Power Supply Transformer in Smoke Detector IXA-4964E in Zone Ppp.Transformer Replaced + (ML20073Q066)
- ML20073Q069 + (ML20073Q069)
- ML20073Q073 + (ML20073Q073)
- L-83-245, Final Deficiency Rept Re Defective Weld on Safety Injection Test Piping.Initially Reported on 830318.Weld,piping & Fitting Replaced & Hanger Reinstalled + (ML20073Q075)
- JPN-91-022, Provides Results of Insp of Weld 28-53.Util Inspected Weld 28-53 During 1991 Maint Outage + (ML20073Q076)
- ML20073Q082 + (ML20073Q082)