- 05000254/LER-1983-017-03, /03L-0:on 830412,RHR Svc Water Pump 1-1001-65C Taken Out of Svc to Facilitate Repair of Broken Coupling on RHR Svc Water Vault Room Cooler 1-5745-C Drain Line.Caused by Overpressurization of Piping + (ML20071G657)
- 05000373/LER-1983-036-03, /03L-0:on 830414,welding Procedures Wps 1-5-A & 5-5-A Discovered in Conflict W/Asme Code.Repairs to Main Steam Drain Line Welds Made Using Subj Procedures.Evaluation of Procedures in Process + (ML20071G659)
- ML20071G660 + (ML20071G660)
- 05000254/LER-1983-018-03, /03L-0:on 830412,excessively High Discharge Pressure & Low Flow Observed from RHR Svc Water Pump 1-1001-65C.Caused by anti-rotation Pin Falling Out of Valve Operator.Pin Replaced & Screw Tightened + (ML20071G662)
- ML20071G665 + (ML20071G665)
- ML20071G667 + (ML20071G667)
- 05000285/LER-1979-015, Forwards LER 79-015/01T-0 + (ML20071G669)
- 05000285/LER-1979-015-01, /01T-0 on 790511:seismic Support Appeared Inadequate for Component Cooling Water piping-to-containment Cooling & Filtering Unit VA-3A.Analyses Indicated That Clamping piping-to-cooling Unit Will Provide Needed Support + (ML20071G672)
- 05000315/LER-1983-034-03, /03L-0:on 830413,pyralarm Detector Alarmed & Found Unplugged,Rendering Fire Zone 4 Detectors Inoperable.Caused by Failure to Plug in Alarm After Conduit Installation. Pyralarm Reinstalled & Sys Verified Operable + (ML20071G676)
- 05000315/LER-1983-035-03, /03L-0:on 830414,deluge Valves for Instrument Room Purge Exhaust 1-HV-CIPX-1 & Control Room Cleanup Sys 1-HV-ACRF-1 Would Not Open Upon Actuation Signal.Caused by Failure of Time Delay Circuit Boards + (ML20071G677)
- 05000301/LER-1983-006-03, /03L-0:on 830419,time Delay Setpoint of Contact from Time Delay Relay 2-TDRC/A06 & 4,160-volt Degraded Grid Voltage Relay 2-275/A06 Set Above Tech Spec Limit.Caused by Bumping or Mispositioning Time Set Knob + (ML20071G681)
- ML20071G684 + (ML20071G684)
- 05000333/LER-1979-029-03, /03L-0 on 790518:during Snubber insp,14 Snubbers Required Some Work & Six Snubbers Were Determined to Be Potentially Inoperable.Snubbers Removed & Tested.Two Snubbers Failed Test & Were Declared Inoperable + (ML20071G685)
- ML20071G700 + (ML20071G700)
- ML20071G704 + (ML20071G704)
- ML20071G706 + (ML20071G706)
- 05000315/LER-1983-036-03, /03L-0:on 830418,eight Charcoal Filter Fill Hole Covers on 12-HV-AFX Spent Fuel Storage Pool Exhaust Ventilation Sys Found Loose.Caused by Lack of Procedure Specifying Correct Matl.New Procedure Written + (ML20071G719)
- ML20071G727 + (ML20071G727)
- 05000301/LER-1983-005-01, /01T-0:on 830428,body-to-bonnet Leak on a Loop RTD Bypass Isolation Valve RC-559A & Boric Acid Wastage of Four Studs Discovered.Leakage Caused Stud Wastage.Studs & Nuts Replaced & Valve on Other Loop Examined + (ML20071G729)
- ML20071G731 + (ML20071G731)
- ML20071G736 + (ML20071G736)
- 05000373/LER-1983-037-03, /03L-0:on 830421,while in Cold Shutdown,Liquid Radwaste Effluent Process Radiation Monitor Declared Inoperable.Caused by Not Performing Acceptable Source Check Due to High Level of Internal Contamination + (ML20071G738)
- ML20071G739 + (ML20071G739)
- ML20071G746 + (ML20071G746)
- 2CAN058306, Informs That Response to NUREG-0737,Item II.E.1.2, Emergency Feedwater Sys Automatic Initiation & Flow Indication, Per 830411 Request,Will Be Provided by 830614. Change Discussed W/E Tourigny + (ML20071G748)
- IR 05000259/2020410 + (ML20071G751)
- ML20071G755 + (ML20071G755)
- 05000249/LER-1983-016-01, /01T-0:on 830504,station Notified That Hydraulic Snubber 16,replaced in Feb 1983,attached on One End Only. Caused by Insufficient Personnel Interface.Work Package Procedures Revised + (ML20071G765)
- ML20071G779 + (ML20071G779)
- ML20071G782 + (ML20071G782)
- 05000315/LER-1982-111-03, During Normal Operation, Auxiliary Cable Vault Experienced Inadvertent Carbon Dioxide Discharge.Caused by Isolation of Main Carbon Dioxide Tank. Valve Isolating Tank Closed & Main Isolation Reopened + (ML20071G785)
- ML20071G786 + (ML20071G786)
- ML20071G789 + (ML20071G789)
- ML20071G792 + (ML20071G792)
- ML20071G793 + (ML20071G793)
- 05000373/LER-1983-040-03, /03L-0:on 830412,stack wide-range Gas Monitor mid-range Noble Gas Recorder OD18-R521 Produced Unusual Readings.Caused by Electronic Noise.Original Power Supply Reinstalled in mid-range Recorder + (ML20071G795)
- ML20071G799 + (ML20071G799)
- ML20071G800 + (ML20071G800)
- IR 05000272/1994016 + (ML20071G803)