- ML20067A556 + (ML20067A556)
- 05000302/LER-1982-067-03, /03L-0:on 821028,feedwater Ultrasonic Flow Indicator FW-313-FI Discovered Inoperable.Caused by Defective Scale Card.Scale Card Replaced & Functional Check Satisfactorily Completed + (ML20067A559)
- 05000331/LER-1994-001-01, :on 940107,determined That Test of Average Power Range Monitor High Flux Scram Trip Setpoint Inadequate.Caused by Unawareness of Test Requirement.Test Verified Clamping Function Set Properly + (ML20067A560)
- ML20067A561 + (ML20067A561)
- ML20067A568 + (ML20067A568)
- ML20067A570 + (ML20067A570)
- 05000302/LER-1982-069, Forwards LER 82-069/03L-0 + (ML20067A571)
- ML20067A572 + (ML20067A572)
- ML20067A575 + (ML20067A575)
- ML20067A576 + (ML20067A576)
- ML20067A578 + (ML20067A578)
- ML20067A579 + (ML20067A579)
- 05000324/LER-1982-098-03, /03L-0:on 821027,measured Vibration Reading of 2B RHR Svc Water Pump Exceeded 1.5 Mils Vibration.Caused by Failed Gasket at Pump Rear Bearing Housing Allowing Loss of Casing Oil,Resulting in Increased Operating Temp + (ML20067A580)
- ML20067A582 + (ML20067A582)
- ML20067A583 + (ML20067A583)
- ML20067A584 + (ML20067A584)
- 05000302/LER-1982-069-03, /03L-0:on 821029,remote & Local 175-ft Wind Direction Channels Found Out of Tolerance.Caused by Failed Direction Sensor.Sensor Replaced & Instrument Recalibr. Meteorological Monitoring Sys Under Evaluation + (ML20067A588)
- ML20067A590 + (ML20067A590)
- ML20067A593 + (ML20067A593)
- ML20067A595 + (ML20067A595)
- ML20067A596 + (ML20067A596)
- 05000498/LER-1994-001, :on 940105,discovered Small Gaps in Reactor Containment Bldg Emergency Sumps Screens.Caused by Less than Adequate Attention to Detail.Repair Dispositions Initiated to Correct Noted Deficiencies in Sump + (ML20067A597)
- ML20067A598 + (ML20067A598)
- 05000325/LER-1994-001, :on 940111,Group 8 Isolation Occurred During Restoration from Maint Surveillance Test 1MST-RHR27M.Caused by Defective procedure.1MST-R27M Revised + (ML20067A600)
- 05000280/LER-1982-121, Forwards LER 82-121/03L-0 + (ML20067A602)
- ML20067A603 + (ML20067A603)
- ML20067A608 + (ML20067A608)
- ML20067A612 + (ML20067A612)
- ML20067A613 + (ML20067A613)
- 05000280/LER-1982-121-03, /03L-0:on 821026,alarm Setpoint for Liquid Waste Monitor RM-LW-108 Exceeded Allowable Tech Spec Limits.Caused by Instrument Drift.Operator Took Administrative Control for High Alarm Isolation.Monitor Recalibr + (ML20067A614)
- 05000334/LER-1994-001, :on 940109,required Plant Shutdown Occurred Due to Inoperable Train of Recirculation Spray Hxs.Caused by Inaccurate Indications.Unit Was Shutdown & a Train Heat Exchangers Cleaned + (ML20067A620)
- ML20067A623 + (ML20067A623)
- 05000296/LER-1982-052, Forwards LER 82-052/03L-0 + (ML20067A625)
- ML20067A626 + (ML20067A626)
- ML20067A633 + (ML20067A633)
- ML20067A634 + (ML20067A634)
- ML20067A638 + (ML20067A638)
- 05000296/LER-1982-052-03, /03L-0:on 821103,CAM 3-RR-90-256 (Drywell Atmosphere Monitor) Became Inoperable.Caused by Sample Pump Failure Due to Normal End of Svc Life.Schwitzer Series 325 Vacuum Pump Rebuilt & Returned to Svc + (ML20067A639)
- ML20067A641 + (ML20067A641)
- ML20067A644 + (ML20067A644)
- ML20067A646 + (ML20067A646)
- ML20067A647 + (ML20067A647)
- ML20067A652 + (ML20067A652)
- ML20067A660 + (ML20067A660)
- LD-94-009, Forwards Amend U to C-E SSAR-Design Certification + (ML20067A670)
- ML20067A671 + (ML20067A671)
- 05000324/LER-1982-129, Forwards LER 82-129/03L-0 + (ML20067A675)
- ML20067A683 + (ML20067A683)
- 05000324/LER-1982-129-03, /03L-0:on 821028,while Verifying Rod Drive Coupling for Rod 18-07,rod Overtravel Annunciator Received. Cause Unknown.Rod Will Be Inspected for Irregularities During Next Scheduled Control Rod Drive Rebuilding Outage + (ML20067A684)
- ML20067A686 + (ML20067A686)
- ML20067A687 + (ML20067A687)