Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20065T084 + (ML20065T084)
- ML20065T085 + (ML20065T085)
- ML20065T088 + (ML20065T088)
- ML20065T094 + (ML20065T094)
- ML20065T100 + (ML20065T100)
- ML20065T102 + (ML20065T102)
- ML20065T103 + (ML20065T103)
- 05000317/LER-1982-061-03, /03X-0:on 820926,pressurizer Level Deviated from Program Level During Normal Startup.Rcs Temp Swings of 10 Degrees Not Uncommon During Startup.Justification for Tech Spec Relaxation Reanalyzed + (ML20065T106)
- ML20065T108 + (ML20065T108)
- ML20065T111 + (ML20065T111)
- ML20065T114 + (ML20065T114)
- 05000333/LER-1990-035, :on 901115,three 3-inch Swing Check Valves Failed to Close During Testing Due to Corrosion & Silt Accumulation in Hinge Pin Mechanism.Valve Internals Replaced W/Stainless Steel Components + (ML20065T115)
- ML20065T118 + (ML20065T118)
- 1CAN098209, Forwards Monthly Operating Rept for Aug 1982 + (ML20065T121)
- ML20065T124 + (ML20065T124)
- ML20065T125 + (ML20065T125)
- ML20065T127 + (ML20065T127)
- ML20065T128 + (ML20065T128)
- 05000311/LER-1982-119, Forwards LER 82-119/01T-0.Detailed Event Analysis Encl + (ML20065T133)
- ML20065T136 + (ML20065T136)
- ML20065T139 + (ML20065T139)
- ML20065T141 + (ML20065T141)
- PY-CEI-NRR-1256, Forwards Update on NRC Bulletin 90-001 Re Potential Loss of fill-oil in Rosemount Transmitters,Per .Items 1-5 of bulletin-requested Actions Completed & Designated Transmitters Which Exhibited Loss of fill-oil Identified + (ML20065T143)
- ML20065T146 + (ML20065T146)
- ML20065T148 + (ML20065T148)
- ML20065T149 + (ML20065T149)
- ML20065T150 + (ML20065T150)
- ML20065T153 + (ML20065T153)
- ML20065T157 + (ML20065T157)
- ML20065T161 + (ML20065T161)
- ML20065T163 + (ML20065T163)
- ML20065T166 + (ML20065T166)
- ML20065T168 + (ML20065T168)
- ML20065T174 + (ML20065T174)
- 05000324/LER-1990-018-02, :on 901123,HPCI Steam Leak Detection Channel B Logic Blew & HPCI Sys Manually Isolated.Probably Caused by Blown Fuse & Loose Wire.Relay & Fuse Replaced + (ML20065T177)
- RBG-34174, Forwards NRC Form 474, Simulation Facility Certification, Per 10CFR55.45(b)(5)(i) + (ML20065T178)
- ML20065T179 + (ML20065T179)
- BSEP-90-0827, Special Rept 1-SR-90-004:on 901121,7-day Time Frame of LCO Exceeded.Caused by Fire Barrier Penetration Seal Out of Svc for Inservice Insp Work.Until Work Completed,Hourly Fire Watch Patrol Will Remain in Effect + (ML20065T181)
- 05000325/LER-1990-024-01, :on 901124,one Reactor Bldg Ventilation Exhaust Damper Closed & Reactor Bldg Ventilation Supply & Exhaust Fans Tripped.Cause Under Investigation.Suppl to Rept Will Be Issued by 910331 + (ML20065T183)
- ML20065T185 + (ML20065T185)
- ML20065T187 + (ML20065T187)
- 05000361/LER-1982-123, Forwards LER 82-123/03L-0.Detailed Event Analysis Submitted + (ML20065T188)
- ML20065T192 + (ML20065T192)
- ML20065T196 + (ML20065T196)
- ML20065T201 + (ML20065T201)
- 05000361/LER-1982-123-03, /03L-0:on 820922,while in Mode 2,condensate Storage Tank T-120 Water Level Fell Below Tech Spec Limit, Rendering Tank Inoperable.Caused by Inadequate Makeup Water Control.Better pre-planning on Water Usage Discussed + (ML20065T205)
- 05000368/LER-1982-032, Forwards LER 82-032/03L-0 + (ML20065T208)
- 05000364/LER-1990-005-01, :on 901216,total of 574 Tubes Previously in Svc Found to Be Defective Which Requires Insp Results to Be Classified as Category C-3 + (ML20065T211)
- ML20065T214 + (ML20065T214)
- ML20065T219 + (ML20065T219)
- TXX-3584, Interim Deficiency Rept Re Pipe Restraint Weld Indications. Initially Reported on 820930.Investigation Continuing.Final Rept Expected by 830103 + (ML20065T224)