s h Public Service'
=";.*-l1,..
P.O. Box 840 Denv r co 80201 0840 December 19, 1990 fort St. Vrain Unit No. 1 A. Clegg Crawford P 90371
$ldgl,b, U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555 ATTN:
Mr. Seymour H. Weiss, Director Non Power Reactor, Decommissioning and Environmental Project Directorate Docket No. 50-267
SUBJECT:
Removal and Disposal of Region Constraint Devices
REFERENCES:
(1) NRC Letter, Heitner to Williams, dated August 30, 1989 (G-89304) Fort St. Vrain Nucle:r Generating Station, Amendment No. 72 To Facility Operating License No. DPR-34 (TAC No. 73418)
(2)
NRC Letter,-Weiss to Crawford, dated itay 1, 1990 (G-90102) Confirmatory Order on Shutdown of Fort St. Vrain (TAC NO. 75114)
(3) NRC Letter, Weiss.to Crawford, dated November 29, 1990 (G-90285) Component Removal Activities
Dear Mr. Weiss:
This letter is to notify -you of Public Service Company of Colorado's (PSC) intent to begin removing and disposing of Region Constraint Devices from the Fort St. Vrain (FSV) plant starting January 4,1991.
-This activity shall be accomplished in accordance with the provisions of ~10 CFR 50.59 and will not limit the choice of reasonable
. decommissioning alternatives nor substantially increase _ the cost of FSV decommissioning.
This activity is being undertaken at this time to maintain a high productivity level in the FSV work force, and is necessary to avoid an increase in the cost of FSV decommissioning.
On August 30, 1989, the NRC issued an Amendment (Reference 1) to the Fort St. Vrain facility operating license limiting reactor power to 2%
of full power af ter June 30, 1990.
In Reference 2, the NRC ordered PSC to not bring the Fort St. Vrain reactor to criticality nor operate the plant at any power level.
The Region Constraint Devices are only necessary to limit core region movements and prevent reactor temperature fluctuations at power levels approaching 70%.
This component removal and disposal activity does not constitute an irreversible action in keeping with the requirements of Reference 3.
18 i 9012270270 901219 fDR ADOCK 05000267 o
PDR (g
a P-90371 Page 2 December 19, 1990 PSC considers that this activity is fully in compliance with applicable regulations and license requirements.
If you have any questions about the information presen'.ed herein, please contact Mr.
M. H. Holmes at (303) 480-6960.
Very truly yours, (f db b fuf tp A. Clegg Crawford Vice President Nuclear Operations ACC/ HLB:geb cc:
Regional Administrator, Region IV ATTN:
Mr. G. L. Constable, Chief Technical Support Section Division of Reactor Projects Mr. J. B. Baird Senior Resident Inspector Fort St. Vrain
- _ _ _ _ _ _ _ _ _ _ _ _ _. _. _. _. _ _ _ _ _ _. _ _ _ _ _ _ _ _. _ _ _. _. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _