Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000387/LER-1982-070-03, /03L-0:on 821208,while Reviewing Past Completed Surveillances for Determining Component Operability, Operational Condition 2 Entered Prior to Required Surveillances.Caused by Lack of Trigger Mechanism + (ML20064H548)
- ML20064H552 + (ML20064H552)
- 05000316/LER-1982-107-03, /03L-0:on 821207,AB Diesel Generator Removed from Svc to Repair Small Fuel Oil Leak Resulting in Inability of Operable Charging Pump to Be Fed from Emergency Power Source.Cause Undetermined.Pump Fuel Line & Fitting Replaced + (ML20064H554)
- ML20064H556 + (ML20064H556)
- ML20064H561 + (ML20064H561)
- PY-CEI-NRR-1770, Monthly Operating Rept for Feb 1994 for Perry Nuclear Power Plant + (ML20064H570)
- 05000361/LER-1982-147, Forwards LER 82-147/03L-0.Detailed Event Analysis Submitted + (ML20064H572)
- 05000325/LER-1978-089, Forwards LER 78-089/03L-0 + (ML20064H583)
- ML20064H584 + (ML20064H584)
- DCL-94-047, Forwards Change 3 to Rev 18 to Physical Security Plan.Encl Withheld + (ML20064H588)
- 05000325/LER-1978-089-03, /03L-0 on 781114:during Periodic Test 9.3.a the HPCI Egr Actuator Failed to Oper Properly Due to Water in Hydraulic Fluid Corroding Egr Actuator.Steam Leaking Past Seat of Valve HPCI E41-F001 Allowed Water Into Fluid + (ML20064H589)
- 05000361/LER-1982-147-03, /03L-0:on 821201,while in Mode 1,condensate Storage Tank T-120 Water Level Fell Below Tech Spec Limit. Caused by Inadequate Makeup Water Control to Tank Due to Misalignment of Valves.Operators Retrained + (ML20064H590)
- 05000325/LER-1978-088, Forwards LER 78-088/03L-0 + (ML20064H594)
- 05000316/LER-1982-108-03, /03L-0:on 821216,during Testing on Diesel Generator Load Shedding relays,4-kV Bus Degraded Voltage Relays 27-T21A-1,27-T21D-2 & 27-T21D-3 Found Exceeding Tech Spec Limit.Caused by Instrument Drift.Relays Readjusted + (ML20064H595)
- 05000325/LER-1978-088-03, /03L-0 on 781114:Fire Hoses of Radwaste Bldg 3 Elevation Fire Stations Were Found Missing Due to Use by Personnel for Routine Radwaste Washdown.New Firehoses Installed & Mod Re Alternate Water Supply Is in Progress + (ML20064H597)
- ML20064H599 + (ML20064H599)
- ML20064H602 + (ML20064H602)
- ML20064H603 + (ML20064H603)
- ML20064H608 + (ML20064H608)
- ML20064H609 + (ML20064H609)
- 05000366/LER-1982-132, Forwards LER 82-132/03L-0 + (ML20064H610)
- 05000325/LER-1978-087, Forwards LER 78-087/03L-0 + (ML20064H613)
- 05000325/LER-1978-087-03, /03L-0 on 781114:torus Level of the HPCI Turbine Control Sys Was Slightly Above the Allowed 27 Inches.Proper Torus Level Restored to Normal.Torus Level Indicator Will Be More Clearly Marked + (ML20064H618)
- ML20064H620 + (ML20064H620)
- 05000362/LER-1982-003, Forwards LER 82-003/03L-0.Detailed Event Analysis Submitted + (ML20064H626)
- 05000324/LER-1982-109, Forwards LER 82-109/03L-0 + (ML20064H632)
- ML20064H634 + (ML20064H634)
- 05000366/LER-1982-132-03, /03L-0:on 821203,while Performing Daily Inside Rounds Procedure,Rhr Svc Water Valve B Found Inoperable. Caused by Pinhole Leak in Valve Body Via Internal Erosion. Valve Repaired + (ML20064H636)
- 05000362/LER-1982-003-03, /03L-0:on 821127,while in Mode 6,channel 2 Startup Monitor 3JI-006 Lost Visual Indication & Declared Inoperable.Caused by Loss of Power When Monitor Control Ctr 3BN Taken Out of Svc.Load Lists Will Be Reviewed + (ML20064H644)
- 05000324/LER-1982-109-03, /03L-0:on 821207,measured Liquid Nitrogen Inventory in Containment Atmosphere Dilution Tank Exceeded 4,350 Gallons.Caused by Lifting of Tank Pressure Relief Valves Due to Loss of Vacuum within Tank Insulation Jacket + (ML20064H651)
- ML20064H653 + (ML20064H653)
- ML20064H654 + (ML20064H654)
- ML20064H659 + (ML20064H659)
- ML20064H660 + (ML20064H660)
- ML20064H667 + (ML20064H667)
- 05000324/LER-1981-135, Forwarded Updated LER 81-135/03L-1 + (ML20064H673)
- ML20064H676 + (ML20064H676)
- ML20064H678 + (ML20064H678)
- ML20064H680 + (ML20064H680)
- ML20064H686 + (ML20064H686)
- ST-HL-AE-4735, Suppl to 930108 Special Rept Re 8R Cylinder Exhaust Temp Exceeding Max Allowable Operating Exhaust Temp of 980 F, During Performance of Sdg 11 Operability Test on 921209. Original Classification as Valid Failure Changed to No Test + (ML20064H687)
- ML20064H690 + (ML20064H690)
- 05000324/LER-1981-135-03, RTGB Instruments 2-CAC-LR-2602 & 2-CAC-LI-2601-3 Indicated Water Level Exceeding Tech Specs.Caused by Change in Trickle Flow to Wet Ref Legs of Instrument Transmitters.Transmitters Calibr + (ML20064H698)
- ML20064H702 + (ML20064H702)
- ML20064H706 + (ML20064H706)
- ML20064H709 + (ML20064H709)
- ML20064H710 + (ML20064H710)
- ML20064H714 + (ML20064H714)
- ML20064H718 + (ML20064H718)
- ML20064H725 + (ML20064H725)
- ML20064H729 + (ML20064H729)