- 05000259/LER-1978-031, Forwards LER 78-031/03L-0 + (ML20064E164)
- ML20064E167 + (ML20064E167)
- 05000259/LER-1978-031-03, /03L-0 on 781016:two Zones of Fire Protec Fixed Spray Piping in Reactor Bldg Were Found Transposed Due to Misinterpretation of Drawings Causing Incorrect Installation of Piping.Piping Has Been Reconnected to Agree W/Drawings + (ML20064E169)
- ML20064E171 + (ML20064E171)
- ML20064E173 + (ML20064E173)
- 05000348/LER-1978-077-03, /03L-0:on 781011,1B Diesel Generator Declared in Oper When Inner Stage Relief on B Air Compressor Lifted. Cause:Desiccant from Recently Installed Air Dryers.B Air Compressor Replaced & Desiccant Removed + (ML20064E175)
- ML20064E177 + (ML20064E177)
- ML20064E180 + (ML20064E180)
- ML20064E193 + (ML20064E193)
- ML20064E198 + (ML20064E198)
- ML20064E214 + (ML20064E214)
- ML20064E216 + (ML20064E216)
- ML20064E217 + (ML20064E217)
- ML20064E221 + (ML20064E221)
- ML20064E225 + (ML20064E225)
- ML20064E231 + (ML20064E231)
- ML20064E234 + (ML20064E234)
- 05000425/LER-1994-001-01, :on 940107,reactor Automatically Tripped Due to Generator Turbine Trip Resulting from Trip of Switchyard Breakers.Caused by Loose Connection on Neutral Side of Shunt Reactor.Connection Tightened + (ML20064E235)
- ML20064E237 + (ML20064E237)
- ML20064E238 + (ML20064E238)
- ML20064E242 + (ML20064E242)
- ML20064E246 + (ML20064E246)
- ML20064E251 + (ML20064E251)
- ML20064E253 + (ML20064E253)
- ML20064E265 + (ML20064E265)
- ML20064E268 + (ML20064E268)
- ML20064E271 + (ML20064E271)
- ML20064E274 + (ML20064E274)
- ML20064E276 + (ML20064E276)
- ML20064E278 + (ML20064E278)
- ML20064E282 + (ML20064E282)
- ML20064E283 + (ML20064E283)
- ML20064E285 + (ML20064E285)
- ML20064E287 + (ML20064E287)
- 05000325/LER-1978-076, Forwards LER 78-076/03L-0 + (ML20064E288)
- 05000325/LER-1978-076-03, /03L-0 on 781011:torus Level Dropped Below Tech Spec Minimum While Water from Torus Was Being Pumped,Via Rgr to Radwaste in Efforts to Reduce Torus Water Level. Caused by Operator Being Distracted + (ML20064E292)
- ML20064E293 + (ML20064E293)
- ML20064E295 + (ML20064E295)
- ML20064E296 + (ML20064E296)
- ML20064E298 + (ML20064E298)
- ML20064E299 + (ML20064E299)
- 05000271/LER-1978-031, Forwards LER 78-031/03L-0 + (ML20064E305)
- ML20064E307 + (ML20064E307)
- 05000271/LER-1978-031-03, /03L-0 on 781016:weekly Review of Completed Surveillance Test Following Plant Startup Noted That Monthly Hydrogen Detector Functional Test Was Not Performed Due to Personnel Error + (ML20064E310)
- ML20064E311 + (ML20064E311)
- 05000271/LER-1994-001, :on 940106,nonconservative TS Setpoint Range Applied to Calibr Procedure for Rod Block Monitor auto- Bypass Feature.Caused by Personnel Error.Setpoint Change Request Processed & OP 4304 Revised + (ML20064E313)
- ML20064E316 + (ML20064E316)
- ML20064E321 + (ML20064E321)
- ML20064E322 + (ML20064E322)
- 05000271/LER-1978-032, Forwards LER 78-032/03L-0 + (ML20064E323)
- 05000271/LER-1978-032-03, /03L-0 on 781014:during Surveillance Test of Main Steam Isolution Valves,V2-86C Closed in 2.6 Seconds Rather than 3-5 Seconds Req in Tech Spec 4.7.D.1.a.1.Caused by Closing Speed Control Valve Coming Loose from Actuator + (ML20064E328)