Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20059J321 + (ML20059J321)
- ML20059J322 + (ML20059J322)
- 05000458/LER-1990-026, :on 900810,RWCU Isolated.Caused by Short Circuit During Jumper Manipulation.Prompt Maint Work Order Initiated to Replace Blown Fuses + (ML20059J324)
- ML20059J330 + (ML20059J330)
- ML20059J332 + (ML20059J332)
- ML20059J334 + (ML20059J334)
- ML20059J335 + (ML20059J335)
- ML20059J336 + (ML20059J336)
- ML20059J337 + (ML20059J337)
- 05000313/LER-1990-008, :on 900809,determined That Control Room Wall Not Seismically Qualified.Caused by Engineering Error in Accepting Deficient Installation During Const of Wall.Review of All Masonary Walls in Progress + (ML20059J339)
- ML20059J342 + (ML20059J342)
- ML20059J345 + (ML20059J345)
- ML20059J347 + (ML20059J347)
- 05000327/LER-1990-013, :on 900601,removal of Lighting Diffuser Panels in Control Room Affected Air Flow Pattern Rendering Smoke Detectors Inoperable.Caused by Inadequate Design Review. Discipline Fire Protection Review Clarified + (ML20059J349)
- 05000458/LER-1990-025, :on 900809,surveillance Requirements Not Performed on Valve Due to Omission from Tech Spec Table 3.6.4-1.Caused by Personnel Oversight.Monthly Operating Log Revised + (ML20059J351)
- 05000289/LER-1993-007, :on 931008,pressure Isolation Valve Failed to Seat Tightly During Plant Operation Due to Loose Hinge Mechanism.Replaced Internals of Pressure Isolation Valve + (ML20059J352)
- ML20059J354 + (ML20059J354)
- ML20059J355 + (ML20059J355)
- ML20059J356 + (ML20059J356)
- ML20059J357 + (ML20059J357)
- ML20059J359 + (ML20059J359)
- IR 05000482/1990014 + (ML20059J362)
- ML20059J363 + (ML20059J363)
- RC-93-0283, Responds to 930621 GL 93-04,Rod Control Sys Failure & Withdrawal of Rod Control Cluster Assemblies, Per 10CFR50.54(f) + (ML20059J364)
- ML20059J365 + (ML20059J365)
- ML20059J366 + (ML20059J366)
- ML20059J367 + (ML20059J367)
- 05000461/LER-1990-015, ;on 900816,inadvertent Shorting of Circuit Card Edge Connectors Occurred During Card Removal.Shorting Caused Isolation Signal & Half Scram.Caused by Personnel Error. Technician Counseled + (ML20059J376)
- ML20059J384 + (ML20059J384)
- ML20059J387 + (ML20059J387)
- PY-CEI-NRR-1226, Forwards LERs 90-018-00 & 90-019-00 for Plant + (ML20059J401)
- ML20059J404 + (ML20059J404)
- 05000282/LER-1990-009-01, :on 900811,automatic Start of Component Cooling Pump Occurred.Caused by Momentary Low Pressure in Component Cooling Water Sys.Procedures to Be Revised to Warn Operator of Possibility of Automatic Pump Starts + (ML20059J415)
- ML20059J421 + (ML20059J421)
- ML20059J425 + (ML20059J425)
- ML20059J428 + (ML20059J428)
- LD-93-158, Requests Counsel on Sys 80+ Design Certification Project Be Placed on Svc List to Receive Documents Re General Electric Advanced Boiling Water Reactor Design Certification Application & Rulemaking + (ML20059J440)
- PY-CEI-NRR-1188, Application for Amend to License NPF-58,revising Tech Specs Re Recalculation of Reactor Vessel pressure-temp Limits,Per Generic Ltr 88-11 + (ML20059J443)
- ML20059J447 + (ML20059J447)
- ML20059J450 + (ML20059J450)
- ML20059J453 + (ML20059J453)
- ML20059J456 + (ML20059J456)
- ML20059J459 + (ML20059J459)
- ML20059J460 + (ML20059J460)
- ML20059J461 + (ML20059J461)
- ML20059J462 + (ML20059J462)
- ML20059J463 + (ML20059J463)
- 05000440/LER-1990-019, On 900817 & 0901,liquid Radiological Effluent Releases Performed W/Radioactive Effluent Monitoring Instrumentation Inoperable W/O Completing Independent,Per Tech Spec 3.3.7.9.On 900820,channel Improperly Calibr + (ML20059J464)
- ML20059J469 + (ML20059J469)
- ML20059J471 + (ML20059J471)
- 05000440/LER-1990-018, :on 900817,determined That Containment Average Temp/Relative Humidity Not Verified within Tech Spec Figure 3.6.5.2-1 Limits.Caused by Programmatic Weakness in Use of Process Computer Sys Info to Determine Tech Spec Compliance + (ML20059J473)