Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20055C571 + (ML20055C571)
- ML20055C573 + (ML20055C573)
- ML20055C575 + (ML20055C575)
- ML20055C576 + (ML20055C576)
- ML20055C577 + (ML20055C577)
- ML20055C579 + (ML20055C579)
- ML20055C580 + (ML20055C580)
- RBG-31618, Part 21 Rept Re Defect in Standby Diesel Engine Replacement Rocker Arm Assembly Supplied by Cooper Industries.Caused by Use of Oversized Casting.Rocker Arm Assembly & Corrector Rod Replaced & Exhaust Valve Stems Readjusted + (ML20055C581)
- ML20055C585 + (ML20055C585)
- ML20055C587 + (ML20055C587)
- ML20055C588 + (ML20055C588)
- ML20055C590 + (ML20055C590)
- ML20055C591 + (ML20055C591)
- ML20055C592 + (ML20055C592)
- ML20055C593 + (ML20055C593)
- ML20055C594 + (ML20055C594)
- 05000424/LER-1990-011, :on 900425,reactor Manually Tripped Due to Inadvertent Closure of Main Feed Regulating Valve.Caused by Mispositioning of Local Control Levers.Local Control Levers Removed + (ML20055C596)
- ML20055C597 + (ML20055C597)
- ML20055C598 + (ML20055C598)
- ML20055C600 + (ML20055C600)
- ML20055C601 + (ML20055C601)
- IR 05000213/1990007 + (ML20055C603)
- W3P90-1314, Requests NRC Concurrence That Design/Controls/Testing to Minimize Potential for Common Header Blockage Acceptable Per 900510 Meeting.Tap Alternatives for Shutdown Cooling Level Indication Sys Discussed + (ML20055C604)
- ML20055C605 + (ML20055C605)
- ML20055C607 + (ML20055C607)
- ML20055C608 + (ML20055C608)
- ML20055C610 + (ML20055C610)
- ML20055C611 + (ML20055C611)
- ML20055C612 + (ML20055C612)
- RBG-32874, Special Rept:On 900430,0502,03,04 & 05,temps in Diesel Generator Control Rooms 1A &/Or 1B Higher than Tech Spec Limit of 104 F for More than 8 H.Caused by Heat Generated by keep-warm Sys.Mod to Increase Exhaust Fan Capacity Written + (ML20055C613)
- ML20055C615 + (ML20055C615)
- ML20055C616 + (ML20055C616)
- NUREG-1402, Forwards NUREG-1402, Closeout of NRC Bulletin 88-005: Nonconforming Matls Supplied by Piping Supplies,Inc,At Folsom,Nj & West Jersey Mfg Co at Williamstown,Nj. Staff Evaluation of Response to Bulletin Closed + (ML20055C618)
- ML20055C619 + (ML20055C619)
- ML20055C621 + (ML20055C621)
- IR 05000456/1990010 + (ML20055C622)
- ML20055C623 + (ML20055C623)
- ML20055C624 + (ML20055C624)
- IR 05000354/1990006 + (ML20055C626)
- ML20055C628 + (ML20055C628)
- ML20055C629 + (ML20055C629)
- ML20055C630 + (ML20055C630)
- TXX-9018, Advises of Completion of Implementation of Requirements of Generic Ltr 89-13, Svc Water Sys Problems Affecting Safety- Related Equipment + (ML20055C633)
- ML20055C634 + (ML20055C634)
- ML20055C635 + (ML20055C635)
- ML20055C637 + (ML20055C637)
- PNO-I-90-042, on 900519,security Discovered Unauthorized Firearm Behind Seat of Contractor Truck in Protected Area. Driver Stated Weapon Hidden Under Numerous Other Items & Slipped His Mind.Firearm Almost Rusted Closed + (ML20055C638)
- PNO-I-90-041A, on 900509,75 Gallons of Contaminated Water Spilled Out of TN-RAM Cask & Into Trench.Cask Should Contain No free-standing Liquid.Cask Placed in Secured Parking Area within Burial Site.State of CT Notified + (ML20055C639)
- 05000457/LER-1990-005-09, :on 900426,discovered That Diesel Generator 2A Starting Air Distribution Sys Tubing Crisscrossed to Cylinders 6L & 9L.Caused by Preservice Mfg Deficiency. Custom-routed Airlines Replaced + (ML20055C643)
- 05000368/LER-1990-011, :on 900425,discovered That post-accident Hydrogen Analyzers Did Not Appear Independent Due to Sharing Common Nitrogen Bottle Supplies.Caused by Design Oversight. Plant Mod Re Nitrogen Supplies Initiated + (ML20055C648)
- 05000368/LER-1989-022, :on 891114,4,160-volt Ac ESF Electric Bus Unexpectedly Deenergized During post-maint Testing on Auxiliary Relay.Caused by Inadequate Test Controls.Job Order Changed to Include Test Switch + (ML20055C649)