May 21,1990 c
Docket No. 50 271 Mr. L. A. Tremblay Licensing-Engineer Vermont Yankee Nuclear Power Corporation 580 Main Street Bolton, Massachusetts 01740 1398
Dear Mr. Trembley:
SUBJECT:
NRC BULLETIN 90 02 (TAC 76353). VERMONT YANKEE NUCLEAR POWER STATION NRC Bulletin 90 02, " Loss of Thermal Margin Caused by Box Bow," dated March 20, 1990, was issued to request that licensees determine whether any channel boxes are being reused after their bundle lifetime and, if so, to ensure that the effects of channel box bow on the critical power ratio are properly taken into account.
By letter dated April-27, 1990, Vermont Yankee Nuclear Power Corporation responded to this bulletin and stated that Vermont Yankee does not presently use channel boxes incore for longer than one bundle lifetime. Any future reuse of channels for a second-bundle lifetime would be evaluated to ensure that the effects of channel box bow on the critical power ratio (CPR) are properly taken into account. Therefore, the staff concludes that Vermont Yankee meets the requirements of Bulletin 90 02.
i This completes the requirements for TAC 76353.
i Original signed by Ronald Eaton for i
Morton B. Fairtile, Project Manager Project Directorate 1 3 Division of Reactor Projects I/II Office of Nuclear Reactor Regulation cc: See next page DISTRIBUTION:-
Docket Filet 0 271 OGC (info)
HRC & Local PDRs EJordan PDI.3 Readina AChu BBoger ACRS(10)
MRushbrook JJohnson, Pegion 1
-Mfairtile p
^
0FC -
- PDI.3/LA
- PDI-3/FM
- PDI.3/D
.......:......j.,....:.. n NAME':MRhh
...... :....t........... :....../,h....... : M F u i r t i l d u
o
- AChu
- RWes.
n DATE 105 M /90
- 05k/90
- 05/>)/90
- 05/b /90 bocunenk hECORD bDY FFICIA ame:
YANKEE TAC 76353 I
9005290076 900521
(\\f PDR ADOCK 05000271 G
7,
.,t-Mr. L. A. Tremblay Vermont Yankee l
CC:
Mr. J. Gary Weigand Chairman, Board of Selectmen President &-Chief Executive Officer Town of Vernon Vermont Yankee Nuclear Power Corp.
Post Office Box 116 R.D. 5, Box 169 Vernon, Vermont 05353-0116 i
Ferry Road Prattleboro, Vermont 05301 Mr. Raymond N. McCandless Vermont ' uision of Occupational Mr. John DeVincentis, Vice President and by : logical Health Yankee Atomic Electric Company Administration Building 580 Main Street Montpelier, Vermont 05602 Bolton, Massachusetts 01740-1398 Honorable John J. Easton New England Coalition on. Nuclear Attorney General.
Pollution State of Vermont Hill and Dale Farm 109 State Street R.D. 2, Box 223 Montpelier, Vermont 05602 Putney, Vermont 05346 Vermont Public Interest Research Group, Inc.
43 State Street Montpelier, Vermont 05602 Diane Curran, Esq.
Regional Administrator, Region 1 Harmon, Curran & Tousley U.S. Nuclear Regulatory Commission 2001 S Street, N.W., Suite 430 475 Allendale Road Washington, D.C.
20009 King of Prussia, Pennsylvania 19406 James Volz, Esq.
R. K. Gad, III-Special Assistant Attorney General Ropes & Gray Vermont Department of Public Service One International Place 120 State Street Boston, Massachusetts 02110 Montpelier, Vermont 05602 l
Mr. W. P. Murphy, Vice President G. Dana Bisbee, Esq.
I and Manager of Operations Office of the Attorney General l
Vermont Yankee Nuclear Power Corporation Environmental Protection Bureau l
R.D. 5, Box 169 State House Anney Ferry Road 25 Capitol Street Brattleboro, Vermont 05301 Concord, New Hampshire 03301-6397 tir. Geo'rge Sterzinger, Commissioner Atomic Safety and Licensing Board l
Vermont Department of Public Service U.S. Nuclear Regulatory Comission l
120 State Street, 3rd Floor Washington 0.C. 20555 Montpetier, Vermont 05602 Public Service Poard State of Vermont I
120 State Street Montpelier, Vermont 05602 1
0
-,,,-,,L
'Mr. L. A. Tremblay Vermont Yankee cc:
Mr. Gustave A. Linenberger,Jr.
Robert M. Lazo, Chairman.
Administrative Judge Atomic Safety and licensing Board Atomic Safety and Licensing Board U. S. Nuclear Regulatory Comission U.S. Nuclear Regulatory Comission Washington, D.C. 20555 Washington, D.C.
20555 Frederick J. Shon Resident inspector Administrative Judge Vermont Yankee Nuclear Power Station Atomic Safety and Licensing Board U.S. Nuclear Regulatory Comission U. S. Nuclear Regulatory Comission P.O. Box 176 Washington, D.C. 20555 Vernon, Vermont 05354 Jerry Harbour John Traficonte Esq.
Administrative Judge Chief Safety Unit Atomic Safety and Licensing Board Office of the Attorney General U. S. Nuclear Regulatory Comission One Ashburton Place, 19th Floor Washington, D.C. 20555 Boston, Massachusetts 02108 Geoffrey M. Huntington, Esquire Office of the Attorney General Environmental Protection Bureau State House Annex 25 Capitol Street Concord, New Hampshire 03301-6397 Charles Bechhoefer, Esq.
Administrative Judge Atomic Safety and Licensing Poard U.S. Nuclear Regulatory Comission Washington, D.C.
20555 Dr. James H. Carpenter Administrative Judge Atomic Safety and Licensing Board U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Adjudicatory File (2) l Atomic Sefety and Licensing Board l-Panel Docket l~
U.S. Nuclear Regulatory Comission Washing' ton, D.C. 20555 l
l
-.