Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 3F0693-06, Responds to NRC Re Violation Noted in Insp Rept 50-302/93-11.Corrective Actions:Addl Administrative Controls on Switchyard Activities Established & Administrative & Interface Documents Will Be Reviewed + (ML20045B457)
- PY-CEI-NRR-1666, Monthly Operating Rept for May 1993 for Pnpp,Unit 1 + (ML20045B458)
- ML20045B459 + (ML20045B459)
- ML20045B461 + (ML20045B461)
- ML20045B462 + (ML20045B462)
- ML20045B463 + (ML20045B463)
- ML20045B464 + (ML20045B464)
- ML20045B466 + (ML20045B466)
- ML20045B467 + (ML20045B467)
- ML20045B468 + (ML20045B468)
- 05000298/LER-1993-021, :on 930611,determined That RB Ventilation Exhaust Inboard Isolation Valve HV-AOV-261AV Inoperable & Open Due to Personnel Error.Subj Valve Manually Closed. Proposed Change to TS Will Be Submitted + (ML20045B470)
- ML20045B471 + (ML20045B471)
- 05000354/LER-1993-004-02, :on 930516,component Failure in EHC Sys Resulted in Generator/Turbine Trip & Reactor Scram.Failed Components Replaced & Addl Monitoring Devices Installed on EHC Sys + (ML20045B476)
- ML20045B479 + (ML20045B479)
- ML20045B480 + (ML20045B480)
- ML20045B481 + (ML20045B481)
- ML20045B482 + (ML20045B482)
- ML20045B485 + (ML20045B485)
- IR 05000213/1993007 + (ML20045B488)
- IR 05000373/1993010 + (ML20045B489)
- ML20045B492 + (ML20045B492)
- ML20045B493 + (ML20045B493)
- ML20045B494 + (ML20045B494)
- ML20045B496 + (ML20045B496)
- ML20045B498 + (ML20045B498)
- ML20045B499 + (ML20045B499)
- ML20045B500 + (ML20045B500)
- ML20045B504 + (ML20045B504)
- ML20045B507 + (ML20045B507)
- ML20045B510 + (ML20045B510)
- ML20045B511 + (ML20045B511)
- IR 05000373/1993016 + (ML20045B512)
- IR 05000352/1993004 + (ML20045B513)
- ML20045B515 + (ML20045B515)
- IR 05000220/1993004 + (ML20045B517)
- ML20045B519 + (ML20045B519)
- IR 05000440/1993013 + (ML20045B523)
- ML20045B527 + (ML20045B527)
- ML20045B529 + (ML20045B529)
- ML20045B530 + (ML20045B530)
- ML20045B531 + (ML20045B531)
- ML20045B532 + (ML20045B532)
- ML20045B533 + (ML20045B533)
- B14506, Forwards Request for Relief from ASME Code Section XI Requirements to Make Interim Repairs to Leak in Svc Water Sys Piping Line 3SWP-150-104-3 as Alternative to IWA-7000 Replacement,Per GL 90-05 + (ML20045B534)
- ML20045B535 + (ML20045B535)
- ML20045B536 + (ML20045B536)
- ML20045B539 + (ML20045B539)
- ML20045B541 + (ML20045B541)
- ML20045B543 + (ML20045B543)
- IR 05000282/1993007 + (ML20045B544)
- IR 05000317/1993013 + (ML20045B545)