Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20041B286 + (ML20041B286)
- ML20041B288 + (ML20041B288)
- ML20041B291 + (ML20041B291)
- ML20041B292 + (ML20041B292)
- ML20041B293 + (ML20041B293)
- ML20041B298 + (ML20041B298)
- 05000334/LER-1982-003, Forwards LER 82-003/04T-0 + (ML20041B299)
- ML20041B301 + (ML20041B301)
- ML20041B303 + (ML20041B303)
- ML20041B305 + (ML20041B305)
- 05000334/LER-1982-003-04, /04T-0:on 820208,tritium Activity in Quarterly Composite of Weekly Grab Samples Found to Be 1430 pci/1. Cause Not Stated.Amend to ETS Submitted Which Would Increase Present Limit + (ML20041B309)
- ML20041B310 + (ML20041B310)
- ML20041B313 + (ML20041B313)
- ML20041B314 + (ML20041B314)
- ML20041B318 + (ML20041B318)
- ML20041B319 + (ML20041B319)
- ML20041B322 + (ML20041B322)
- ML20041B323 + (ML20041B323)
- ML20041B324 + (ML20041B324)
- ML20041B325 + (ML20041B325)
- IR 05000267/1981028 + (ML20041B326)
- ML20041B327 + (ML20041B327)
- ML20041B332 + (ML20041B332)
- 05000320/LER-1982-003, Forwards LER 82-003/03L-0 + (ML20041B333)
- ML20041B335 + (ML20041B335)
- ML20041B336 + (ML20041B336)
- RBG-12-112, Interim Deficiency Rept Re HPCS Diesel Generator Radioactive Heat Loss Value Used in Sizing of HPCS Room Cooling Design. Revised Design Will Employ Same Size Cooling Fans as Used for Standby Diesel Generator Rooms + (ML20041B337)
- ML20041B339 + (ML20041B339)
- ML20041B341 + (ML20041B341)
- 05000320/LER-1982-003-03, /03L-0:on 820111,during Weekly Scheduled Preventive Maint,Pump NR-P-1B Failed to Start.Caused by Loose Fuse Clip in Control Power Switchgear.Clip Repaired + (ML20041B342)
- ML20041B343 + (ML20041B343)
- ML20041B345 + (ML20041B345)
- ML20041B347 + (ML20041B347)
- IR 05000382/1981021 + (ML20041B348)
- ML20041B349 + (ML20041B349)
- ML20041B350 + (ML20041B350)
- ML20041B353 + (ML20041B353)
- PNO-III-82-021, on 820212, Steam Leak Discovered in 150-psig High Pressure Exhaust Steam Line from Turbine.Caused by 8-inch Crack on Weld Joining 24-inch Piping w/37.5-inch Exhaust Leading to Moisture Separator Reheater + (ML20041B354)
- ML20041B355 + (ML20041B355)
- ML20041B357 + (ML20041B357)
- ML20041B359 + (ML20041B359)
- ML20041B361 + (ML20041B361)
- ML20041B362 + (ML20041B362)
- ML20041B363 + (ML20041B363)
- 05000331/LER-1982-005, Forwards LER 82-005/03L-0 + (ML20041B366)
- 05000305/LER-1982-003, Forwards LER 82-003/03L-0 + (ML20041B368)
- ML20041B372 + (ML20041B372)
- 05000331/LER-1982-005-03, /03L-0:on 820114,torus Water Level Recorder Lr 4385 Found in Failed Downscale Condition.Caused by Excessive Heat Buildup in Recorder Cabinet Due to Poor Ventilation. Cabinet Being Kept Open Temporarily to Increase Cooling + (ML20041B375)
- ML20041B376 + (ML20041B376)
- 05000305/LER-1982-003-03, /03L-0:on 820116,1A Zone SV Fan Started Automatically.Caused by Solenoid Valve Failure Due to Burned Out Coil in Closed Position Which Automatically Opened Damper.Coil Replaced & Sys Tested Satisfactorily + (ML20041B379)
- ML20041B380 + (ML20041B380)