- AECM-81-518, Interim Deficiency Rept Re Thermal Cycling of Reactor Vessel Head During Hot Operations,Initially Reported 811201.GE Analysis of Effect on Reactor Vessel Fatigue Cycle Lifetime Continuing.Final Rept Will Be Submitted by 820219 + (ML20039F345)
- 05000366/LER-1981-118, Forwards LER 81-118/03L-0 + (ML20039F346)
- ML20039F348 + (ML20039F348)
- ML20039F349 + (ML20039F349)
- ML20039F351 + (ML20039F351)
- 05000321/LER-1981-127, Forwards LER 81-127/03L-0 + (ML20039F352)
- ML20039F354 + (ML20039F354)
- IR 05000508/1981020 + (ML20039F356)
- 05000321/LER-1981-127-03, /03L-0:on 811126,during Test,Turbine Failed to Trip Electrically & HPCI Sys Declared Inoperable.Caused by Failed HPCI Electrical Trip Solenoid Valve Due to Continuous Activation During Previous Outage.Coil Replaced + (ML20039F358)
- ML20039F359 + (ML20039F359)
- ML20039F360 + (ML20039F360)
- ML20039F362 + (ML20039F362)
- 05000321/LER-1981-135, Forwards LER 81-135/03L-0 + (ML20039F363)
- 05000366/LER-1981-118-03, /03L-0:on 811119,drywell Temp Recorder 2T48-R627 Declared Inoperable.Caused by Loose Umbilical Power Connector.Connector Secured.Recorder Returned to Svc.Generic Review Revealed No Inherent Problems + (ML20039F366)
- ML20039F368 + (ML20039F368)
- 05000321/LER-1981-135-03, /03L-0:on 811215,level of Both Fire Protection Water Storage Tanks Dropped Below Tech Spec Requirement. Caused by Ruptured Fire Main in Low Voltage Switchyard. Rupture Isolated & Tanks Restored to Required Level + (ML20039F371)
- IR 05000312/1981032 + (ML20039F373)
- ML20039F374 + (ML20039F374)
- 05000321/LER-1981-134, Forwards LER 81-134/03L-0 + (ML20039F375)
- ML20039F378 + (ML20039F378)
- 05000321/LER-1981-134-03, /03L-0:on 811208,two Fire Doors Found Open.Caused by Failure to Carry Fire Watch Over to Following Shift When Fire Doors Opened to Transfer Water from Unit 1 Radwaste to Unit 2 Radwaste.Fire Watch Tracking Initiated + (ML20039F382)
- ML20039F383 + (ML20039F383)
- ML20039F384 + (ML20039F384)
- 05000296/LER-1981-070, Forwards LER 81-070/03L-0 + (ML20039F385)
- ML20039F387 + (ML20039F387)
- ML20039F388 + (ML20039F388)
- 05000296/LER-1981-070-03, /03L-0:on 811211,during Normal Operation, HPCI Suppression Chamber High Level Switches Found 8 Inches Above Normal.Caused by Tech Spec Change Revising Normal Water Levels.Level Switches 73-57A & B Lowered + (ML20039F389)
- ML20039F391 + (ML20039F391)
- IR 05000288/1981001 + (ML20039F392)
- ML20039F393 + (ML20039F393)
- ML20039F394 + (ML20039F394)
- ML20039F395 + (ML20039F395)
- ML20039F398 + (ML20039F398)
- ML20039F399 + (ML20039F399)
- ML20039F400 + (ML20039F400)
- 05000325/LER-1981-094, Forwards LER 81-094/03L-0 + (ML20039F403)
- ML20039F405 + (ML20039F405)
- GO2-81-055, Final Deficiency Rept Re Incorrectly Installed Class IE 250-volt Battery,Initially Reported 811202.New Battery Installation Will Be Purchased from Exide + (ML20039F406)
- 05000325/LER-1981-094-03, /03L-0:on 811205,08 & 10,suppression Chamber Water Level Recorder Indicated Levels Less than Actual Level. Caused by Change in Trickle Flow to Wet Ref Leg of Recorder Transmitter Causing Functioning Out of Calibr + (ML20039F407)
- ML20039F408 + (ML20039F408)
- ML20039F409 + (ML20039F409)
- ML20039F410 + (ML20039F410)
- ML20039F411 + (ML20039F411)
- ML20039F412 + (ML20039F412)
- ML20039F413 + (ML20039F413)
- ML20039F414 + (ML20039F414)
- ML20039F416 + (ML20039F416)
- ML20039F417 + (ML20039F417)
- PNO-III-82-004, on 820105,Campbell Pacific Soil Density Gauge Was Stolen from Licensee Vehicle Parked at Hammond,In Shopping Ctr.Gauge Contains 10 Mci Cs-137 & 50 Mci Am-241 + (ML20039F418)
- ML20039F419 + (ML20039F419)
- IR 05000206/1981037 + (ML20039F420)