Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20039F236 + (ML20039F236)
- NUREG/CR-1900, Confirms Request to Discuss Util Participation in Source Term Measurement Program.Site Tour & Meeting Will Be Held on 811222.NUREG/CR-1900 Which Documents Measurement Results at Four Sites Encl.W/O Encl + (ML20039F237)
- ML20039F238 + (ML20039F238)
- ML20039F239 + (ML20039F239)
- ML20039F241 + (ML20039F241)
- ML20039F242 + (ML20039F242)
- ML20039F247 + (ML20039F247)
- ML20039F249 + (ML20039F249)
- ML20039F250 + (ML20039F250)
- ML20039F251 + (ML20039F251)
- ML20039F252 + (ML20039F252)
- 05000339/LER-1981-078, Updated LER 81-078/03X-1:on 811008-29,boron Concentration in Safety Injection Accumulators,Exceeded Tech Specs.Caused by Leakage Into Makeup Supply Header from Spent Fuel Pit. Accumulator Refilled W/Borated Water + (ML20039F254)
- ML20039F255 + (ML20039F255)
- 05000327/LER-1981-155, Forwards LER 81-155/03L-0 + (ML20039F256)
- 05000366/LER-1981-123, Forwards LER 81-123/03L-0 + (ML20039F258)
- ML20039F260 + (ML20039F260)
- ML20039F261 + (ML20039F261)
- ML20039F262 + (ML20039F262)
- 05000366/LER-1981-123-03, /03L-0:on 811208,standby Gas Treatment Filter Train 2T46-C001B Tripped & Would Not Restart While Venting Primary Containment.Caused by Heater Control Relays Chattering.Relay Replaced + (ML20039F263)
- 05000327/LER-1981-155-03, /03L-0:on 811209,diesel Generator 2A-A Would Not Load Past 1.3 MW During Performance of Surveillance Instructions 7 & 102.Caused by Defective Solder Joint on Speed Control Motor Plug on Hydraulic Governor + (ML20039F264)
- ML20039F265 + (ML20039F265)
- ML20039F268 + (ML20039F268)
- ML20039F270 + (ML20039F270)
- 05000339/LER-1981-070, Forwards Updated LER 81-070/03X-1 + (ML20039F271)
- ML20039F274 + (ML20039F274)
- ML20039F275 + (ML20039F275)
- 05000339/LER-1981-087, Forwards LER 81-087/03L-0 + (ML20039F276)
- 05000364/LER-1981-051-03, /03L-0:on 811205,overtemp Delta Temp Instrumentation Loop Declared Inoperable When Bistable TB- 432C-1 Found Out of Tech Spec Tolerance.Caused by Comparator Card Being Out of Calibr.Card Recalibr.Loop Test Completed + (ML20039F278)
- 05000339/LER-1981-087-03, /03L-0:on 811203,while in Mode 1 Operation,Fire Doors from Cable Vault to Auxiliary Bldg & Rod Drive Room Would Not Close Automatically.Caused by Failure of Automatic Closure Mechanism.Closure Mechanism Replaced + (ML20039F279)
- 05000339/LER-1981-070-03, Boron Concentration in Safety Injection Accumulators Exceeded Tech Specs.Caused by Leakage Into Makeup Supply Header from Spent Fuel Pit. Accumulator Refilled W/Borated Water + (ML20039F280)
- 05000364/LER-1981-052-03, /03L-0:on 811206,A Train Control Room Chlorine Detector Declared Inoperable Due to Paper Not Advancing. Caused by Scrap of Paper Jamming Paper Drive Gears.Paper Removed + (ML20039F281)
- ML20039F282 + (ML20039F282)
- 05000338/LER-1981-084, Forwards LER 81-084/03L-0 + (ML20039F283)
- 05000339/LER-1981-066, Forwards Updated LER 81-066/03X-1 + (ML20039F285)
- ML20039F287 + (ML20039F287)
- 05000369/LER-1981-189, Forwards LER 81-189/03L-0 + (ML20039F288)
- 05000338/LER-1981-084-03, /03L-0:on 811203,while in Mode 1 Operation,Doors Between Rod Drive Room & Auxiliary Bldg Failed to Close & Latch Automatically.Caused by Closure & Latching Mechanism Failure or by Door Misalignment.Doors Repaired + (ML20039F292)
- ML20039F293 + (ML20039F293)
- ML20039F294 + (ML20039F294)
- 05000369/LER-1981-189-03, /03L-0:on 811130,pressurizer Pressure Slowly Decreased & Pressurizer Backup Heaters Violated Tech Specs by Automatically Energizing & Restoring Pressure.Caused by Open Breakers on Heater Power Panels.Extensive Mods Planned + (ML20039F295)
- 05000339/LER-1981-066-03, Boron Concentration in 1C Safety Injection Accumulator Exceeded Max Tech Specs Limit. Caused by Inleakage Into Makeup Supply Header from Spent Fuel Pit.Concentration Restored by Draining Accumulator + (ML20039F296)
- ML20039F297 + (ML20039F297)
- 05000369/LER-1981-190, Forwards LER 81-190/03L-0 + (ML20039F298)
- 05000366/LER-1981-128, Forwards LER 81-128/03L-0 + (ML20039F300)
- ML20039F302 + (ML20039F302)
- ML20039F303 + (ML20039F303)
- 05000369/LER-1981-190-03, /03L-0:on 811203,lower Personnel Airlock Door on Reactor Bldg Side of Airlock Declared Inoperable Due to Ruptured Seal.Caused by Mfg Design Oversight.Seal Replaced. Procedural Change Should Prevent Similar Failures + (ML20039F304)
- 05000366/LER-1981-120, Forwards LER 81-120/03L-0 + (ML20039F305)
- 05000366/LER-1981-128-03, /03L-0:on 811215,door 2RW21 to Drum Conveyor Aisle Discovered Open & Unattended.Caused by Midnight Shift Personnel Error.Door Found Open by Health Physics Personnel & Immediately Locked.Personnel Cautioned + (ML20039F307)
- ML20039F308 + (ML20039F308)
- 05000287/LER-1981-016, Forwards LER 81-016/03L-0.Detailed Event Analysis Encl + (ML20039F309)