c' 4[,qW 2
\\ wy r Babcock & Wilcox
% -ceneau-amuo
[
Y P.O. Box 1260. Lynchburg. Va. 24505
~
Telephone: (804) 384-5111 1-
.g 9
p March 29, 1976 Docket STN 50-561 Director of Nuclear Reacter Regulation ATTACHMENT A TO BE ATTN:
Mr. Roger S. Boyd, Director WITHHELD FROM Division of Project Management PUBLIC DISCLOSURE U. -S. Nuclear Regulatory Commission Washington, D. C.
20555
Subject:
B-SAR 205 Transmittal of Amendment 1
References:
(1)
Ltr., R.S. Boyd, NRC to K.E. Suhrke, January 23, 1976,
" Summary of NRC/B&W Meeting Held on January 8, 1976."
(2)
Ltr., J.H. MacMillan to R.S. Boyd, March 8, 1976, p
" Confirmation of Agreement Concerning Format for System Operating Sequence Diagrams.
(3) 'Ltr., J.H. MacMillan to R.S. Boyd, February 27, 1976,
" Submittal of Docket Copies of B-SAR-205."
Dear Mr. Boyd:
+
The Babcock & Wilcox Company herewith submits 73 copies of B-SAR-205 Amendment 1.
Instructions for incorporating the revised material into the B-SAR-205 are included in the amendment.
Babcock & Wilcox also submits herewith four (4) copies of B-SAR Amendment pages 13.7-1 through 13.7-5 concerning industrial security which are to be withheld from public disclosure in accordance with 10 CFR 2.790(d).
This attachment is identified as Attachment A.
The Babcock & Wilcox Company also submits herewith twenty-five (25) copies of replacement page 5 for insertion in the 25 copies of "B-SAR-205 General Information Required by 10 CFR 50.33" which were submitted to your office on February 27, 1976.
This attachment is identified as Attachment B.
The subject page has been amended to state that The Babcock & Wilcox Company is not acting as an agent or representative of another person in making tha B-SAR application.
Picase remove and destroy existing page 5 in all copies of the referenced document and replace with the attached revised page S.
F201120279 810403 3d"Ul n/
PDR FOIA MADDEN 80-515 PDR The Babcock & Wdcox Company / Established 1867
Babcock &Wilcox go.e, cene,.uon c,ou, P.O. Box 1260, Lynchburg, Va. 24505 Telephone:(804) ?8&S111 March 29, 1976 Docket STN 50-561 Director of Nuclear Reactor Regulation ATTACHMENT A TO BE ATTN:
Mr. Roger S. Boyd, Director WITHHELD FROM Division of Project Management PUBLIC DISCLOSURE U. S. Nuclear Regulatory Commission Washington, D. C.
20555
Subject:
B-SAR 205 Transmittal of Amendment 1
References:
(1)
Ltr., R.S. Boyd, NRC to K.E. Suhrke, January 23, 1976,
" Summary of NRC/B&W Meeting Held on January 8, 1976."
(2)
Ltr., J.H. MacMillan to R.S. Boyd, March 8, 1976,
" Confirmation of Agreement Concerning Format for System Operating Sequence Diagrams."
(3)
Ltr., J.H. MacMillan to R.S. Boyd, February 27, 1976,
" Submittal of Docket Copies of B-SAR-205."
Dear Mr. Boyd:
The Babcock & Wilcox Company herewith submits 73 copies of B-SAR-205 Amendment 1.
Instructions for incorporating the revised material into the B-SAR-205 are included in the amendment.
Babcock & Wilcox also submits herewith four (4) copies of B-SAR Amendment pages 13.7-1 through 13.7-5 concerning industrial security which are to be withheld from public disclosure in accordance with 10 CFR 2.790(d).
This attachment is identified as Attachment A.
The Babcock & Wilcox Company also submits herewith twenty-five (25) copies l
of replacement page 5 for insertion in the 25 copies of "B-SAR-205 General Information Required by 10 CFR 50.33" which were submitted to your office on l
February 27, 1976. This attachment is identified as Attachment B.
i The subject page has been amended to state that The Babcock & Wilcox Company is not acting as an agent or representative of another person in making the l
B-SAR application.
Please remove and destroy existing page 5 in all copies of the referenced document and replace with the attached revised page 5.
l The Babcock & Wilccx Company / Estabhshed 1867
Babcock & Wilcox m
Mr. Roger S. Boyd March 29, 1976 The following comments apply to Amendment 1:
(1) The amendment specifically includes material requested by the Staff in Enclosure 2 in the attachment to reference (1).
In addition, as committed in reference (3), this amendment also includes responses to Enclosure 1 questions 212.8, 331.6, 020.2, 212.9 (Part C), and 212.10 (Parts 2-7).
(2)
Responses to questions 212.10, 212.74, and 212.75 are being submitted as Attachment C to this letter. These responses should be inserted in numerical order in the B-SAR section titled "NRC Questions."
These responses will be integrated into the B-SAR as part of forth-coming Amendment 2.
(3)
Responses to questions 212.71, 212.73 and to Item 5 ef question 212.80 are not yet complete.
It is planned to submit responses to these items as part of Amendment 2.
(4)
Amendment 1 includes a text page relating to Industrial Security which contains the statement that the original material is being withheld from public disclosure and which identifies the letter transmitting the text pages to your office and to the I&E Regional Office.
In this regard, we have followed the general requirements of NRC PM operating procedure 207.
(5) This amendment also corrects a number of typographical errors in earlier submittals and includes a number of clarifying revisions informally suggested by the Staff during meetings and telephone conversations.
Of note here are (1) the relocation of physical interface tables to a more convenient position adjacent to the referenced process and instrumentation drawing (P&ID), and (2) modification to interface symbols on the P& ids to make them more obvious to the Staff.
(6) System operating sequence diagrams in Chapter 15 have been modified to be in accord with the agreements made in reference (2).
(7)
It was agreed at a meeting with the Staff on March 12, 1976, that only safety-related interfaces need to be identified on B-SAR P&ID figures and related physical interface tables.
It has not been
~s
Babcock & Wilcox m
Mr. Roger S. Boyd March 29, 1976 possible to delete non-safety-related interface symbols and related tabular identifications in this amendment.
Such items will be deleted in future amendments.
Very truly yours, BABCOCK & WILCOX COMPANY NUCLEAR POWER GENERATION DIVISION N-b i
FJohn H. MacMillan Division Vice President JIDf:nw Enclosures cc:
U. S. Nuclear Regulatory Commission Office of Inspection and Enforcement - Region IV 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76012 f
e I
Babcock & Wilcox STATE OF VIRGINIA)
) ss CITY OF LYNCHBUP.G)
Russell M. Ball, Being first duly sworn, deposes and says: That he is the Senior Technical Consultant of the Nuclear Power Generation Division of the BABC0CK & WILCOX COMPANY, the applicant herein; that he is authorized to submit the foregoing on behalf of said applicant; that he has read the foregoing and knows the contents hereof; and believes the same to be true to the best of his knowledge.
2[
Ad,4
, 1976 DATED:
,+= M Al
~
Russell M. Ball Subscribed and sworn to before me This L9 day of 2/M,1976.
he =
'!.Un 1
Notary Public in and for the State of Virginia, residing at wr CQs L.
Lynchburg, Virginia 24503 My Commission enires:
1
~
f NHC romu 195 u.s. NUCLEAR GECULATORY eoMMISSacN ooCK2T NUMKE A
. a.m STN-50-561
]
.NRC DISTRIBUTION ron PART 50 DCCKET MATERIAL To: NRC FHom:
Babcock & Wilcox oATE oF ooCUMENT f
- 3-29-76 Lynchburg, Va.
24505 i
J. Paa MacMillian oATE nEcEivEo 4 76 1
!etETTEn OnoToatzEo enon incurronu NUusER or COPIES RECEIVEo I
D omic'N AL DohcLAssimito 25 scoeY n ocenserion Ltr notarized 3-29-76 trans the EnctosumE Replacement Page 5 for insertion i
following::
in fhe 25 copies of B-SARc205 General Info f
portion of application.. 4 l
(25 cys enc 1 re.c'd)
'~~~
\\'
- = = ~ ~
I I
. - = = = = = ~ ~ ~
e I
-m.
i I TLANT NAME:
B-SAR-205 S
SAFETY FOR ACTION /INFORMATION ENVIRO UML
'+-/-to l
' 9 SIGNED AD :
ASSIGNED AD :
4/
ANCH CHIEF :
(.2)
.$.f.o L2_
BRANCH CHIEF.
8/
.dOJECT MANAGER:
' j #n v 3 PROJECT MANAGER : -
4.s LIC. ASST. :
gm j4 y LIC. ASST. :
INTERNAL DISTRIBUTION
/ REG FILE I
SYSTEMS SAFETY PT Ah"r WmvR vmfrun er tr t/
NRC PLR HETru t rrnFqco ERNST a
t#
I&E (M ScHRornFR BENAROYA BALLARD
_/
OEI D L\\INAS af SPANGLER GOSSICK & STAFF ENGINEERING IPPOLITO 1
MIPC MAccu y SITE TECH CASE KNIGHT OPERATING REACTORS CAn!ILL HAllaUER SIlfIEIL STELLO STEPP PE LESS l PAWLICKI HULMAN l
} OPERATING TECH I
1 a
i PROJECT MANAGEMENT I I REACTOR SAFETY i l EISENHITr SITE ANALYSIS BOYD ROSS I
SHAO VOLLMER P. COLLINS NOVAK BAER BUNCH HO'JSTON ROSZTOCZY SCHUENCER J. COLLINS PETERSON CHECK GRIMES KREGER V
MELTZ RELTEMES AT & I SITE SAFETY &_ENVIRC N OVil0LT d
SALTZMAN ANALYSIS RITrBERG DENTON Fe PUT.LER i
EXTERNAL f)lSTRIBUTION CONTROL NUMBE R
_f LPDR NATL LAB g/ BROOKl!AVEN NATL LAB l/
CONSULTANTS
._l/ _ACRS 3 N ellEl.
TO 4*8'
'